Hammond 1589T48F116 48-Inch 16-Outlet Vertical PDU, 20A 5-20R
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 16 NEMA 5-20R front-facing outlets, 20A / 125VAC heavy-duty black receptacles with single T-slot
- 48.00 in (1219 mm) strip length; 1231.09 mm (48.468 in) overall assembly length
- Rated 20A, 120VAC single-phase; resettable 20 Amp circuit breaker
- Pilot light power indicator version (no on/off switch)
- 6 ft integral 12/3 SJT 12 gauge cord with molded NEMA 5-20P straight blade plug
- Anodized aluminum extrusion case with ABS plastic ends, Natural finish, low-profile slim design
- Mounting bracket kit with hardware included; extra kits available as P/N 1585CLIP
- UL Listed UL1363 / cUL, CSA C22.2 No. 308-14, RoHS and REACH compliant, TAA-compliant
The 1589T48F116 is a 48 in vertical basic PDU (power outlet strip) with 16 NEMA 5-20R receptacles, rated 20A at 120VAC single-phase. It is built for IT, AV and facilities teams who need straightforward rack power distribution in server cabinets, wall mount cabinets and open frame racks, and it can also be mounted horizontally above a work bench.
Construction is a low-profile slim anodized aluminum extrusion with ABS plastic ends, finished in Natural. This version carries a pilot light rather than an on/off switch, so the power indicator confirms the circuit is live, and a resettable 20 Amp circuit breaker protects the strip. The heavy-duty black receptacles are rated 20A, 125VAC (NEMA 5-20R, single T-slot), are 1 in square and are equally spaced along the length of the strip. All 16 outlets face the front; there are no rear outlets, no rotated outlets, no surge protection and no metering.
Power is supplied by an integral 6 ft, heavy duty 12 gauge 12/3 SJT cord suited to extreme temperature ranges, terminating in a molded NEMA 5-20P straight blade plug. Operating temperature range is -20 C to +60 C. Overall assembly length is 1231.09 mm (48.468 in) with a 1224.28 mm (48.200 in) extrusion; shipping weight is 4 lbs (1.81 kg).
A mounting bracket kit with hardware is included; additional kits are available as P/N 1585CLIP. Note that outlet strips cannot be used between the front and rear panel rails of rack cabinets, as they and the equipment plugs will interfere with mounted equipment and accessories — allow sufficient depth behind the rear rails for vertical mounting to the struts.
1589T48F116 is UL Listed to UL1363 and CSA certified, RoHS and REACH compliant, TAA-compliant for federal GSA schedule purchases within the USA, and manufactured in North America.
Ideal For
- Vertical power distribution in server cabinets
- Wall mount cabinet power strips
- Open frame rack and relay rack power
- Horizontal mounting above a work bench
- TAA-compliant federal GSA schedule projects
Overview
| Part Number | 1589T48F116 |
| Switch Type | No Switch. Power Indicator Light |
| Product Type | Vertical Basic PDU |
| Short Description | 20A 16 OUTLET 6' STRAIGHT 48"L |
| On-Off Switch Equivalent Part | 1589H48F116 |
Dimensions
| Nominal Size | 48.00 in (1219 mm) strip length |
| Extrusion Length | 1224.28 mm [48.200 in] |
| Overall Assembly Length | 1231.09 mm [48.468 in] |
Electrical
| Phase | Single-Phase |
| Metered | No |
| Plug Type | NEMA 5-20P straight blade, integral molded plug |
| Cord Length | 6 ft |
| Outlet Size | 1 in square, equally spaced over the length of the strip |
| Outlet Type | NEMA 5-20R (20A, 125VAC, single T-slot, heavy-duty black) |
| Cord Included | Yes |
| Rated Current | 20 A |
| Rated Voltage | 120VAC |
| Shielded Cord | No |
| Total Outlets | 16 |
| Drawing Rating | 125 VAC, 60 Hz, 20 Amps |
| Hospital Grade | No |
| Outlets (Rear) | 0 |
| Outlets (Front) | 16 |
| Rotated Outlets | No |
| Surge Protection | No |
| Cord Construction | Heavy duty 12 gauge, 12/3 SJT |
Identifiers
| UPC | 623980304755 |
| UNSPSC | 39121710 |
| GTIN-14 | 00623980304755 |
Rack Mounting
| Mounting Hardware | Mounting bracket kit with hardware included |
| Installation Note #1 | Outlet strips can NOT be used between the front & rear panel rails of rack cabinets as they (and the equipment plugs) will interfere with mounted equipment and mounted accessories. |
| Installation Note #2 | To properly use on rack cabinets, allow sufficient depth BEHIND the rear panel rails for vertically mounting to the struts. |
| Mounting Orientation | Vertical in cabinets/racks, or horizontal above a work bench |
| Additional Hardware Kit | Order P/N 1585CLIP |
Packaging & Shipping
| Tariff Code | 8537.10.9170 |
| Manufacturing | Manufactured in North America |
| Shipping Weight | 4 lbs (1.81 kg) |
| Country Of Origin | CA |
Construction & Finish
| Color | Natural |
| Design | Low-profile slim design |
| End Caps | ABS plastic |
| Case Material | Anodized aluminum extrusion |
Environmental & Protection
| Operating Temperature | -20 C to +60 C |
Compliance & Certifications
| CSA | CSA C22.2 No. 308-14; CSA Certified Standards C22.2 (No. 21-95, 42-99) |
| ECCN | EAR99 |
| Standards | cULus, TAA-compliant |
| UL File # | E166039 |
| UL Listing | UL/cUL Listed Standard UL1363 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| USMCA Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Does the 1589T48F116 have an on/off switch?▾
No. This is the pilot light version with a power indicator light and no switch. The equivalent model with an on-off switch is 1589H48F116.
What plug and cord does it come with?▾
It ships with a 6 ft heavy duty 12 gauge 12/3 SJT cord with an integral molded NEMA 5-20P straight blade plug.
Is mounting hardware included?▾
Yes, a mounting bracket kit with hardware is included with each outlet strip. Additional hardware kits can be ordered as P/N 1585CLIP.
Can I mount this strip between the front and rear rack rails?▾
No. Per the manufacturer note, outlet strips cannot be used between the front and rear panel rails, because the strip and equipment plugs will interfere with mounted equipment and accessories. Allow sufficient depth behind the rear rails for vertical mounting to the struts.
Is it overcurrent protected?▾
Yes, it includes a resettable 20 Amp circuit breaker. It does not include surge protection or metering.
Is 1589T48F116 suitable for US federal GSA purchases?▾
The series is TAA-compliant for federal GSA schedule purchases within the USA, and this unit is RoHS and REACH compliant, UL Listed to UL1363 and CSA certified.
Related Products
Save 35%1589T48F1 — 20A 8 Outlet Vertical Strip, 6 ft. cord - 48" Long
Hammond Manufacturing · 1589T48F1
Save 35%1589T48G1 — 20A 8 Outlet 15' Strght 48" L
Hammond Manufacturing · 1589T48G1
Save 35%1589T48D116 — 20A 16 Outlet 15' Tw Lck 48" L
Hammond Manufacturing · 1589T48D116
Save 35%1589T48G116 — 20A 16 Outlet 15' Strght 48" L
Hammond Manufacturing · 1589T48G116
Save 35%1589T48D1 — 20A 8 Outlet 15' Tw Lck 48"L
Hammond Manufacturing · 1589T48D1