Hammond SKT011409NC Normally Closed Thermostat, Fahrenheit Scale
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Normally closed contact opens on rising temperature to switch heaters off
- Fahrenheit scale, 30-140°F (0-60°C) adjustment range
- 15A @ 120VAC, 10A @ 240VAC, 30W @ DC switching capacity
- Thermostatic bi-metal sensor, +/- 4°F hysteresis
- Red-imprint setting knob identifies the NC version
- Clips onto 35 or 38 mm DIN rail, clip included
- UL94V0 housing, IP20; UL/cUL Recognized Component, CE
The SKT011409NC is a normally closed (NC) enclosure thermostat with a Fahrenheit scale, from the SKT Series. It provides air temperature control and monitoring in cabinets and is the version used with heaters and heater fans: its contact opens when rising temperature reaches the set point, shutting the heater off. Electricians and panel builders use it to automate enclosure heating instead of leaving heaters powered continuously.
A thermostatic bi-metal sensor drives a snap-action contact, adjustable from 30 to 140°F (0 to 60°C). The switching difference (hysteresis) is + or - 4°F (+ or - 3 K), and the NC setting knob carries a red imprint. The switching capacity is 15A @ 120VAC, 10A @ 240VAC, and 30W @ DC, and noise suppression is class N according to VDE 0875.
The ordering table gives dimensions of 2.8 x 1.5 x 1.4 (height x width x depth); the short description lists 2.41 x 1.3 x 1.4 in. The housing is flame retardant UL94V0 plastic in gray, protected to IP20, with a 2 pole terminal for AWG 14 (2.5 mm²) wire. The thermostat clips onto 35 or 38 mm DIN rail with the included clip.
The instructions call for installation by qualified staff, in the upper part of the cabinet as far as possible from heat-creating components, without covering the ventilation slots. When setting an NC thermostat, add the highest possible hysteresis to the required minimum temperature. The SKT011409NC is UL Recognized Component, cUL Recognized Component and CE approved, RoHS and REACH compliant, and ships at 0.2 lb (0.09 kg).
Ideal For
- Controlling enclosure heaters
- Controlling heater fans
- Cabinet air temperature control and monitoring
- Maintaining minimum temperature in switch cabinets
Overview
| Scale | F° |
| Series | SKT Series Thermostats |
| Contact Type | Normally Closed (contact opens with rising temperature) |
| Product Type | Norm. Closed Thermostat Fahrenheit |
| Setting Knob | Red imprint (NC) |
| Sensor Element | Thermostatic bi-metal |
| Adjustment Range | 30 - 140°F / 0 - 60°C |
| Short Description | THERMOSTAT 2.41X1.3X1.4" |
| Tolerance For Switching Point | +/- 4 K |
| Switching Difference (Hysteresis) | + or - 4°F (+ or - 3 K); instruction sheet: temperature difference < 7 K |
Dimensions
| Size (Short Description) | 2.41 x 1.3 x 1.4 in |
| Height X Width X Depth (Ordering Table) | 2.8 x 1.5 x 1.4 |
Electrical
| Connection | 2 pole terminal for AWG 14 (2.5 mm²) |
| Contact Design | Snap-action contact |
| Noise Suppression | N (according to VDE 0875) |
| Switching Capacity | 15A @ 120VAC, 10A @ 240VAC, 30W @ DC |
| Max. Breaking Capacity (Instruction Sheet) | 240V AC, 10 (2)A / 120V AC, 15 (2)A; DC max. 30W (value in brackets: inductive load at cos φ = 0.6) |
Identifiers
| UPC | 623980565194 |
| UNSPSC | 41112209 |
Rack Mounting
| Mounting | Clip mounting on 35 or 38 mm DIN rail (clip included) |
Packaging & Shipping
| Shipping Weight | 0.2 lbs (0.09 kg) |
Construction & Finish
| Color | Gray (SB) |
| Housing | Flame retardant plastic UL94V0 |
Environmental & Protection
| Protection | IP20 |
| Working Temperature Range (Instruction Sheet) | -20°C .. +80°C / -5°F .. +180°F |
Compliance & Certifications
| Approvals | UL Recognized Component, cUL Recognized Component, CE |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Is the SKT011409NC for heating or cooling?▾
It is the normally closed version, used with heaters and heater fans. The contact opens when rising temperature reaches the set point, shutting the heater off.
What is the adjustment range?▾
30 - 140°F / 0 - 60°C, on a Fahrenheit scale.
What load can it switch?▾
15A @ 120VAC, 10A @ 240VAC, and 30W @ DC.
Where should it be installed in the cabinet?▾
In the upper part of the switch cabinet at the maximum possible distance from heat-creating components, without covering its ventilation slots.
How should I set it for a minimum temperature?▾
Add the highest possible hysteresis to the required minimum temperature. The instruction example sets 20°C (66°F) for a required minimum of 9°C (46°F), adding 11 K (7 K + 4 K).