Hammond 1589T48G116 48-Inch 16-Outlet Vertical PDU, 20A 5-20R
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 16 front-facing NEMA 5-20R heavy-duty black receptacles rated 20A, 125VAC, single T-slot
- 48.00 in (1219 mm) strip length; 48.468 in (1231.09 mm) overall assembly length
- 15 ft 12/3 SJT heavy duty cord with integral molded NEMA 5-20P straight blade plug
- Power indicator light (no on/off switch) plus resettable 20 amp circuit breaker
- Anodized aluminum extrusion case in natural finish with ABS plastic ends; low-profile slim design
- Mounting bracket kit with hardware included; extra kits available as P/N 1585CLIP
- UL Listed UL1363 / CSA certified, TAA-compliant, RoHS and REACH compliant
- Operating temperature -20 C to +60 C; outlets 1 in square, equally spaced along the strip
The 1589T48G116 is a 48 in (1219 mm) vertical basic power distribution unit with 16 NEMA 5-20R receptacles, rated 20A at 120VAC single-phase. It is built for IT, AV and facilities teams that need straightforward plug-and-play power distribution inside server cabinets, wall mount cabinets and open frame racks, or mounted horizontally above a work bench.
The low-profile slim housing is an anodized aluminum extrusion in a natural finish with ABS plastic end caps, keeping the strip rugged but light. All 16 outlets face the front of the strip (none on the rear), are 1 in square and are equally spaced over the length of the unit. This is the pilot light version of the design: instead of an on/off switch it carries a power indicator light, plus a resettable 20 amp circuit breaker. The matching switched version of this configuration is 1589H48G116.
Power comes from an attached 15 ft heavy duty 12/3 SJT cord with an integral molded NEMA 5-20P straight blade plug, suitable for extreme temperature ranges. Operating temperature range is -20 C to +60 C. Overall assembly length is 48.468 in (1231.09 mm) and shipping weight is 6 lbs (2.72 kg).
A mounting bracket kit with hardware is included; additional kits can be ordered as P/N 1585CLIP. Note that outlet strips cannot be used between the front and rear panel rails of rack cabinets, as the strip and equipment plugs will interfere with mounted equipment and accessories; allow sufficient depth behind the rear panel rails when mounting vertically to the struts.
1589T48G116 is UL Listed to UL1363 and CSA certified, TAA-compliant for federal GSA schedule purchases within the USA, RoHS and REACH compliant, and manufactured in North America.
Ideal For
- Vertical power distribution in server cabinets
- Wall mount cabinet power feeds
- Open frame and relay rack installations
- Horizontal mounting above a work bench
- Federal GSA schedule projects requiring TAA-compliant PDUs
Overview
| Series | 1589H-T Series Vertical Basic PDU |
| Description | 20A 16 OUTLET 15' STRGHT 48" L |
| Part Number | 1589T48G116 |
| Outlet Strip Type | Vertical Basic PDU |
Dimensions
| Strip Length | 48.00 in (1219 mm) |
| End View Dimensions | 1.149 in (29.18 mm) and 0.200 in (5.08 mm) |
| Outlet Field Length | 48.200 in (1224.28 mm) |
| Overall Assembly Length | 48.468 in (1231.09 mm) |
| Outlet Spacing Dimension | 1.616 in (41.05 mm) |
| Reference Dimension (Section A-A) | 10.458 in (265.62 mm) |
Electrical
| Phase | Single-phase |
| Metered | No |
| Cord Type | Heavy duty 12 gauge, 12/3 SJT |
| Plug Type | NEMA 5-20P straight blade, integral molded plug |
| Cord Length | 15 ft |
| Outlet Type | NEMA 5-20R (single T-slot), 20A/125V, heavy-duty black |
| Switch Type | No Switch. Power Indicator Light |
| Cord Included | Yes |
| Rated Current | 20 A |
| Rated Voltage | 120VAC |
| Shielded Cord | No |
| Total Outlets | 16 |
| Hospital Grade | No |
| Outlets (Rear) | 0 |
| Circuit Breaker | Resettable 20 amp circuit breaker |
| Outlets (Front) | 16 |
| Rotated Outlets | No |
| Rating (Drawing) | 125 VAC, 60 Hz, 20 Amps |
| Surge Protection | No |
| Outlet Size / Spacing | 1 in square receptacles, equally spaced over the length of the strip |
Identifiers
| UPC | 623980304762 |
| ECCN | EAR99 |
| UNSPSC | 39121710 |
| GTIN-14 | 00623980304762 |
| Tariff Code | 8537.10.9170 |
| Country Of Origin | CA (manufactured in North America) |
| UPC W/o Check Digit | 62398030476 |
Rack Mounting
| Orientation | Vertical (can also be installed horizontally above a work bench) |
| Mounting Note #1 | Outlet strips can NOT be used between the front & rear panel rails of rack cabinets as they (and the equipment plugs) will interfere with mounted equipment and accessories |
| Mounting Note #2 | To properly use on rack cabinets, allow sufficient depth BEHIND the rear panel rails for vertically mounting to the struts |
| Included Accessories | Mounting bracket kit with hardware |
| Additional Mounting Kit | Order P/N 1585CLIP (vertical outlet strip mounting clip kit) |
Packaging & Shipping
| Shipping Weight | 6 lbs (2.72 kg) |
Construction & Finish
| Color | Natural (black finish available upon request) |
| Design | Low-profile slim design, rugged light weight aluminum |
| End Caps | ABS plastic |
| Case Material / Finish | Anodized aluminum extrusion |
Environmental & Protection
| Operating Temperature | -20 C to +60 C |
Compliance & Certifications
| CSA | CSA C22.2 No. 308-14; CSA Certified Standards C22.2 (No. 21-95, 42-99) |
| Standards | cULus, TAA-compliant |
| UL File # | E166039 |
| UL Listing | UL Listed Standard UL1363 |
| RoHS Compliant | Yes |
| TAA Compliance | TAA-compliant for federal GSA schedule purchases within the USA |
| REACH Compliant | Yes |
| USMCA Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Does 1589T48G116 have an on/off switch?▾
No. This is the pilot light version, listed as "No Switch. Power Indicator Light," and it includes a resettable 20 amp circuit breaker. If you need an on/off switch in the same configuration, the series lists 1589H48G116.
What plug and cord does it come with?▾
It includes a 15 ft heavy duty 12/3 SJT cord with an integral molded NEMA 5-20P straight blade plug, rated for extreme temperature ranges.
How many outlets are there and where are they located?▾
There are 16 NEMA 5-20R outlets, all on the front face (16 front, 0 rear). The receptacles are 1 in square and equally spaced over the length of the strip.
Is mounting hardware included?▾
Yes, a mounting bracket kit with hardware is included with the outlet strip. Additional hardware kits can be ordered as P/N 1585CLIP.
Can I mount it between the front and rear rails of a rack cabinet?▾
No. Per the manufacturer notes, outlet strips cannot be used between the front and rear panel rails, because the strip and the equipment plugs will interfere with mounted equipment and accessories. Allow sufficient depth behind the rear panel rails for vertical mounting to the struts.
Is this PDU TAA compliant?▾
Yes. It is TAA-compliant for federal GSA schedule purchases within the USA, and is also RoHS, REACH and USMCA compliant. Country of origin is Canada.
Related Products
Save 35%1589T48G1 — 20A 8 Outlet 15' Strght 48" L
Hammond Manufacturing · 1589T48G1
Save 35%1589T60C1 — 20A 10 Outlet Vertical Strip, 6 ft. cord - T Lock - 60" Long
Hammond Manufacturing · 1589T60C1
Save 35%1589T48F116 — 20A 16 Outlet 6' Straight 48"L
Hammond Manufacturing · 1589T48F116
Save 35%1589T60D1 — 20A 10 Outlet 15' Tw Lck 60" L
Hammond Manufacturing · 1589T60D1
Save 35%1589T48F1 — 20A 8 Outlet Vertical Strip, 6 ft. cord - 48" Long
Hammond Manufacturing · 1589T48F1