Hammond 1589H60C1 60 in Vertical PDU, 10 Outlets, 20A L5-20P
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 10 NEMA 5-20R outlets rated 20A, 125VAC (single T-slot), equally spaced across the 60 in strip, all front-facing
- 20A / 120VAC single-phase rating with resettable 20 Amp circuit breaker and on/off rocker power switch
- 6 ft heavy duty 12/3 SJT cord with integral molded NEMA L5-20P locking plug
- Low-profile slim anodized aluminum extrusion case with ABS plastic ends, Natural finish
- Mounting bracket kit with hardware included; extra kits available as P/N 1585CLIP
- UL Listed to UL1363, cUL/CSA certified, TAA-compliant, RoHS and REACH compliant
- Wide operating temperature range of -20 degrees C to +60 degrees C
- Mounts vertically in server cabinets, wall mount cabinets and open frame racks, or horizontally above a work bench
The 1589H60C1 is a 60 in (1524 mm) vertical basic PDU (power outlet strip) rated 20A at 120VAC, built for IT, AV and electrical teams powering equipment inside server cabinets, wall mount cabinets and open frame racks. It carries 10 heavy-duty black NEMA 5-20R receptacles (20A, 125VAC, single T-slot), all on the front face, spaced equally over the length of the strip, with 1 in square receptacle openings.
Construction is a low-profile slim anodized aluminum extrusion with ABS plastic ends, finished in Natural, making it rugged but light weight. The strip includes an on/off rocker power switch and a resettable 20 Amp circuit breaker. Power is supplied by an integral 6 ft heavy duty 12 gauge cord (12/3 SJT, suited to extreme temperature ranges) with a molded NEMA L5-20P locking plug. Operating temperature range is -20 degrees C to +60 degrees C. This part number has no surge protection, is not metered, is not hospital grade and uses non-rotated, unshielded-cord construction.
Overall assembly length on the drawing is 1535.99 mm [60.472 in], with a body dimension of 1529.08 mm [60.200 in]. Shipping weight is 7 lbs (3.18 kg). A mounting bracket kit with hardware is included; additional kits are available as P/N 1585CLIP. Per the series notes, outlet strips cannot be used between the front and rear panel rails of rack cabinets, and rack cabinet installations should allow sufficient depth behind the rear panel rails for vertical mounting to the struts.
1589H60C1 is UL Listed to UL1363 and cUL/CSA certified, RoHS and REACH compliant, TAA-compliant for federal GSA schedule purchases within the USA, and manufactured in North America.
Ideal For
- Vertical power distribution in server cabinets
- Wall mount cabinet power feeds
- Open frame and relay rack installations
- Horizontal mounting above a work bench
- TAA-compliant federal GSA schedule projects
Overview
| Series | Vertical Basic PDU 1589H-T Series |
| Part Number | 1589H60C1 |
| Outlet Strip Type | Vertical Basic PDU |
| Short Description | 20 AMP POWER BAR, 10 OUTLETS |
| Pilot Light Equivalent Part No. | 1589T60C1 |
Dimensions
| Section Dimension | 41.05 mm [1.616 in] |
| End View Dimensions | 29.18 mm [1.149 in]; 5.08 mm [0.200 in] |
| Body Length (Drawing) | 1529.08 mm [60.200 in] |
| Nominal Size (Strip Length) | 60.00 in (1524 mm) |
| Overall Assembly Length (Drawing) | 1535.99 mm [60.472 in] |
Electrical
| Metered | No |
| Cord Type | Heavy duty 12 gauge, 12/3 SJT with integral molded plug |
| Plug Type | NEMA L5-20P (locking) |
| Cord Length | 6 ft |
| Outlet Type | 5-20R (heavy-duty black receptacles rated 20A, 125VAC, single T-slot) |
| Switch Type | On/Off Rocker Switch |
| Cord Included | Yes |
| Rated Current | 20 Amps |
| Rated Voltage | 120VAC |
| Shielded Cord | No |
| Drawing Rating | 125 VAC, 60 Hz, 20 Amps |
| Hospital Grade | No |
| Outlets (Rear) | 0 |
| Outlets (Front) | 6 |
| Rotated Outlets | No |
| Surge Protection | No |
| Number Of Outlets | 10 |
| Receptacle Opening Size | 1 in square, equally spaced over the length of the strip |
| Total Outlets (Part Attribute) | 6 |
Identifiers
| UPC | 623980196503 |
| UNSPSC | 39121710 |
| GTIN-14 | 00623980196503 |
| UPC W/o Check Digit | 62398019650 |
Packaging & Shipping
| Tariff Code | 8537.10.9170 |
| Manufacturing | Manufactured in North America |
| Shipping Weight | 7 lbs (3.18 kg) |
| Country Of Origin | CA |
Construction & Finish
| Color | Natural |
| Design | Low-profile slim design, rugged light weight aluminum |
| End Caps | ABS plastic |
| Included Accessories | Mounting bracket kit with hardware (additional kit: P/N 1585CLIP) |
| Case Material / Finish | Anodized aluminum extrusion |
Environmental & Protection
| Operating Temperature | -20 degrees C to +60 degrees C |
Compliance & Certifications
| ECCN | EAR99 |
| Standards | cULus, TAA-compliant |
| UL File # | E166039 |
| RoHS Compliant | Yes |
| UL/cUL Listing | UL Listed Standard UL1363 and CSA C22.2 No. 308-14 |
| REACH Compliant | Yes |
| USMCA Compliant | Yes |
| CSA Certification (Drawing) | CSA Certified Standards C22.2 (No. 21-95, 42-99) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
How many outlets does the 1589H60C1 have?▾
The series ordering table and the drawing both show 10 NEMA 5-20R outlets (10x 20A/125V) on this 60 in strip, and the short description reads "20 AMP POWER BAR, 10 OUTLETS". The part page attribute list shows Total Outlets as 6 with 6 front and 0 rear, so both figures are published in the manufacturer data.
What plug and cord come with this PDU?▾
It ships with a 6 ft heavy duty 12 gauge cord (12/3 SJT) with an integral molded NEMA L5-20P locking plug. The cord is not shielded.
Does it have a switch or a pilot light?▾
1589H60C1 is the on/off switch version, with an on/off rocker power switch and a resettable 20 Amp circuit breaker. The pilot light equivalent is part number 1589T60C1.
Is mounting hardware included?▾
Yes. A mounting bracket kit with hardware is included with each outlet strip. Additional hardware kits can be ordered as P/N 1585CLIP.
Can it be installed between the front and rear rails of a rack cabinet?▾
No. Per the series notes, outlet strips cannot be used between the front and rear panel rails because the strip and the equipment plugs will interfere with mounted equipment and accessories. Allow sufficient depth behind the rear panel rails for vertical mounting to the struts.
Does the 1589H60C1 include surge protection or metering?▾
No. This is a basic PDU: surge protection is not provided, it is not metered, and it is not hospital grade.
Related Products
Save 35%1589H48G116 — 20A 16 Outlet 15' Straight 48"
Hammond Manufacturing · 1589H48G116
Save 35%1589H60D1 — 20A 10 Outlet 15' Tw Lck 60" L
Hammond Manufacturing · 1589H60D1
Save 35%1589H48G1 — 20A 8 Outlet 15' Strght 48" L
Hammond Manufacturing · 1589H48G1
Save 35%1589H60F1 — 20 Amp Power Bar, 10 Outlets
Hammond Manufacturing · 1589H60F1
Save 35%1589H48F116 — 20A 16 Outlet 6' Straight 48"L
Hammond Manufacturing · 1589H48F116