(224) 955-1644
Hammond ManufacturingAuthorized partner store
1182U110P 1500 VA toroid power transformer with potted center and flexible leads, 110V @ 13.6A secondary

Hammond 1182U110P 1500 VA Potted Toroid, 220V CT or 110V Output

Hammond Manufacturing|

MPN: 1182U110P

|

UPC: 623980270036

In Stock
$220.56

Ships from and sold by A5 IT

Ground Shipping · $33.99Arrives by Tuesday, Oct 27
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • Two 110 V secondaries: 220V C.T. @ 6.8A or 110V @ 13.6A
  • 1.90% voltage regulation at 1500 VA
  • Potted epoxy center drilled 13/32" for a 3/8 bolt
  • #12 TEW primary and secondary leads
  • 3/8-16 x 4.00" bolt and 6.00" OD rubber washer supplied
  • Dual 117/234 VAC, 50/60 Hz primary (parallel for 117 V, series for 234 V)
  • Class B (130 degree C) materials; 4,000 VAC RMS hi-pot primary to secondary
  • UL recognized (file #E207860) and CSA certified (file #209651)

The 1182U110P is a 1500 VA potted-center toroid power transformer with two 110 V secondaries. Series connection gives 220V C.T. @ 6.8A and parallel connection 110V @ 13.6A. With 1.90% listed regulation it is intended for high-power 110 V or 220 V outputs derived from 117 VAC or 234 VAC mains.

The drawing shows each secondary as 110V @ 6.80 A and specifies #12 TEW primary and secondary leads, 8"-9" long and stripped 0.5" minimum. The epoxy center is filled 0.50" from the top and drilled 13/32" for a 3/8 bolt; supplied hardware is one 0.125" x 6.00" OD rubber washer and one 3/8-16 bolt 4.00" long with lock washer and hex nut. Dimension reference is M. Shipping weight is 23 lbs (10.43 kg); the drawing lists 24.75 lbs +/- 4%.

On compliance, the 1182 family carries UL recognition to UL 5085-1 and UL 5085-2 under file #E207860 and CSA certification to C22.2 #66.1-6 and #66.2-6 under file #209651, and is self-declared as evaluated to applicable sections of IEC/EN61558-1 and IEC/EN61558-2-4. Windings use Class B (130 degree C) materials, primary-to-secondary insulation is hi-pot tested at 4,000 VAC RMS, and the part is listed as RoHS and REACH compliant.

The dual primary accepts 117 VAC (parallel connection) or 234 VAC (series connection) at 50/60 Hz, with a connection sheet included. Units are designed to run with every winding engaged, in series or parallel, or as an autotransformer. Plan the supply protection for toroidal inrush: the magnetizing current at energization is limited only by the primary's low DC resistance, so a slow-blow fuse, time-delayed breaker or soft-start is recommended.

Ideal For

  • 110 V or 220 V center-tapped outputs at 1500 VA
  • Line-voltage isolation where a potted-center toroid is preferred
  • Equipment for both 117 VAC and 234 VAC supplies (global use)
  • Designs needing low stray magnetic flux (low EMI) in a low-profile package

Overview

Series1182 Series - Toroid Power Transformers, 15 VA to 1500 VA
ReplacesOlder 182 Toroid Series
DescriptionPower transformer, toroid, 1500 VA, with 110V @ 13.6A secondary, 1182 Series
Part Number1182U110P
Power Rating1500 VA
Product TypePower transformer, toroid
Toroid CenterPotted
Secondary TypeDual
Short DescriptionTOROID,1500VA,50/60HZ,110/110V
Dimension ReferenceM

Electrical

PolarityAdditive (BLK, BRN, RED and GRY)
Frequency50/60 Hz
Primary VoltageDual 117/234 VAC
Primary Connection117 VAC: parallel connection; 234 VAC: series connection
Voltage Regulation1.90%
Winding ConnectionAll windings engaged (series or parallel connected) or connected as an autotransformer
Inrush Current NoteConsider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line
Secondary (RMS) - Series220V C.T. @ 6.8A
Primary Windings (Drawing)2x 117V BLK-WHT, BRN-ORN
Secondary (RMS) - Parallel110V @ 13.6A
Secondary Windings (Drawing)2x 110V @ 6.80A RED-BLU, GRY-YEL
Hi-Pot Test, Primary - Primary600V, 60Hz, 1 sec
Secondary No-Load Voltage Test@ 117V, 60Hz: BLK & BRN to WHT & ORN; or @ 234V, 50Hz: BLK to ORN (connect BRN & WHT)
Hi-Pot Test, Primary - Secondary4000V, 60Hz, 1 sec
Hi-Pot Test, Secondary - Secondary600V, 60Hz, 1 sec
Voltage Regulation (Part Page, Rounded)2%
Hi-Pot Test, Primary - Secondary (Series Spec)4,000 VAC RMS

Identifiers

UPC623980270036
UNSPSC39121301

Leads & Wiring

Lead LengthMinimum 8" long flexible leads
Connection SheetIncluded with transformer
Primary Lead Wire#12 TEW
Secondary Lead Wire#12 TEW
Primary Lead ColoursBLK-WHT (Primary #1), BRN-ORN (Primary #2)
Secondary Lead ColoursRED-BLU (Secondary #1), GRY-YEL (Secondary #2)
Lead Length & Strip (Drawing)All leads out 8"-9" and stripped 0.5" min.

Mounting Hardware

Supplied Hardware 1One 0.125" T x 6.00" OD rubber washer
Supplied Hardware 2One 3/8-16 bolt 4.00" long with a lock washer and 3/8-16 hex nut

Packaging & Shipping

Shipping Weight23 lbs (10.43 kg)
Weight (Drawing)24.75 lbs +/- 4%
Country Of OriginCanada

Construction & Finish

CoreToroidal
Potted Center1,500 VA size supplied with a potted center for extra strength
Toroid BenefitsLow profile, lightweight, cool running / high efficiency, low stray magnetic flux leakage (low EMI)
Insulation ClassClass B (130 degree C) materials
Potted Center DetailEpoxy center filled 0.50" from the top and drilled 13/32" for a 3/8 bolt

Compliance & Certifications

ULUL recognized to UL 5085-1 and UL 5085-2, UL file #E207860
CSACSA certified to C22.2 #66.1-6 and C22.2 #66.2-6, CSA file #209651
IEC/ENSelf-declared evaluated to applicable sections of IEC/EN61558-1 (Second Edition 2005-09) and IEC/EN61558-2-4
RoHS CompliantYes
REACH CompliantYes
CE (2014 Spec Sheet)CE compliant to IEC 61558-2-4
UL (2014 Spec Sheet)UL recognized to UL506 (XPTQ.Guide), UL file #E207860

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What outputs does the 1182U110P provide?▾

220V C.T. @ 6.8A with the secondaries in series or 110V @ 13.6A in parallel, at 1500 VA.

How is the 1182U110P mounted?▾

Through its potted epoxy center, drilled 13/32" for a 3/8 bolt, with the supplied 3/8-16 x 4.00" bolt, lock washer, hex nut and 0.125" x 6.00" OD rubber washer.

Why might the 1182U110P trip a breaker when switched on?▾

Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time-delayed circuit breaker or soft-start circuitry is recommended on the supply line.

Is it UL and CSA approved?▾

The 1182 series is UL recognized to UL 5085-1 and UL 5085-2 (file #E207860) and CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (file #209651).

How do I wire the primary for 117 V or 234 V?▾

Connect the two 117 V primaries (BLK-WHT and BRN-ORN) in parallel for 117 VAC or in series for 234 VAC, 50/60 Hz. A connection sheet is included with the transformer.