Hammond 1182T30P 750 VA Potted-Center Toroid, 60V CT or 30V Output
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Potted toroid center
- Two 30 V secondaries: 60V C.T. @ 12.5A or 30V @ 25A
- 3.10% voltage regulation at 750 VA
- Shipping weight 13 lbs (5.90 kg)
- Dual 117/234 VAC, 50/60 Hz primary (parallel for 117 V, series for 234 V)
- Class B (130 degree C) materials; 4,000 VAC RMS hi-pot primary to secondary
- UL recognized (file #E207860) and CSA certified (file #209651)
- Toroid core: low profile, lightweight, cool running, low stray flux (low EMI)
The 1182T30P is the potted-center version of the 750 VA, 30 V toroid in the 1182 series. Its dual secondaries deliver 60V C.T. @ 12.5A in series or 30V @ 25A in parallel, and its dual 117 V primaries accept 117 VAC or 234 VAC.
The series ordering table lists the 1182T30P with a potted toroid center, 3.10% regulation and dimension reference K; the part page rounds regulation to 3%. Shipping weight is 13 lbs (5.90 kg). Electrically it matches the open-center 1182T30, so the choice between the two comes down to the center construction your mounting approach needs. Leads are flexible and a minimum of 8" long, as across the series.
On compliance, the 1182 family carries UL recognition to UL 5085-1 and UL 5085-2 under file #E207860 and CSA certification to C22.2 #66.1-6 and #66.2-6 under file #209651, and is self-declared as evaluated to applicable sections of IEC/EN61558-1 and IEC/EN61558-2-4. Windings use Class B (130 degree C) materials, primary-to-secondary insulation is hi-pot tested at 4,000 VAC RMS, and the part is listed as RoHS and REACH compliant.
The dual primary accepts 117 VAC (parallel connection) or 234 VAC (series connection) at 50/60 Hz, with a connection sheet included. Units are designed to run with every winding engaged, in series or parallel, or as an autotransformer. Plan the supply protection for toroidal inrush: the magnetizing current at energization is limited only by the primary's low DC resistance, so a slow-blow fuse, time-delayed breaker or soft-start is recommended.
Ideal For
- 30 V high-current or 60 V center-tapped supplies
- Installations preferring a potted-center toroid
- Equipment for both 117 VAC and 234 VAC supplies (global use)
- Designs needing low stray magnetic flux (low EMI) in a low-profile package
Overview
| Series | 1182 Series - Toroid Power Transformers, 15 VA to 1500 VA |
| Replaces | Older 182 Toroid Series |
| Description | Power transformer, toroid, 750 VA, with 30V @ 25A secondary, 1182 Series |
| Part Number | 1182T30P |
| Power Rating | 750 VA |
| Product Type | Power transformer, toroid |
| Toroid Center | Potted |
| Secondary Type | Dual |
| Short Description | TOROID, 750VA, 50/60HZ, 30/30V |
| Dimension Reference | K |
Electrical
| Frequency | 50/60 Hz |
| Primary Voltage | Dual 117/234 VAC |
| Primary Connection | 117 VAC: parallel connection; 234 VAC: series connection |
| Voltage Regulation | 3.10% |
| Winding Connection | All windings engaged (series or parallel connected) or connected as an autotransformer |
| Inrush Current Note | Consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line |
| Secondary (RMS) - Series | 60V C.T. @ 12.5A |
| Secondary (RMS) - Parallel | 30V @ 25A |
| Hi-Pot Test, Primary - Secondary | 4,000 VAC RMS |
| Voltage Regulation (Part Page, Rounded) | 3% |
Identifiers
| UPC | 623980930435 |
| UNSPSC | 39121301 |
Leads & Wiring
| Lead Length | Minimum 8" long flexible leads |
| Connection Sheet | Included with transformer |
Packaging & Shipping
| Shipping Weight | 13 lbs (5.90 kg) |
Construction & Finish
| Core | Toroidal |
| Toroid Benefits | Low profile, lightweight, cool running / high efficiency, low stray magnetic flux leakage (low EMI) |
| Insulation Class | Class B (130 degree C) materials |
Compliance & Certifications
| UL | UL recognized to UL 5085-1 and UL 5085-2, UL file #E207860 |
| CSA | CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6, CSA file #209651 |
| IEC/EN | Self-declared evaluated to applicable sections of IEC/EN61558-1 (Second Edition 2005-09) and IEC/EN61558-2-4 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CE (2014 Spec Sheet) | CE compliant to IEC 61558-2-4 |
| UL (2014 Spec Sheet) | UL recognized to UL506 (XPTQ.Guide), UL file #E207860 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What does the P in 1182T30P indicate?▾
The series ordering table lists the 1182T30P with a potted toroid center; the 1182T30 has an open center.
What are the 1182T30P output ratings?▾
60V C.T. @ 12.5A with secondaries in series, or 30V @ 25A in parallel, at 750 VA.
Why might the 1182T30P trip a breaker when switched on?▾
Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time-delayed circuit breaker or soft-start circuitry is recommended on the supply line.
Is it UL and CSA approved?▾
The 1182 series is UL recognized to UL 5085-1 and UL 5085-2 (file #E207860) and CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (file #209651).
How do I wire the primary for 117 V or 234 V?▾
Connect the two 117 V primaries (BLK-WHT and BRN-ORN) in parallel for 117 VAC or in series for 234 VAC, 50/60 Hz. A connection sheet is included with the transformer.
Related Products
Save 52%1182T30 — Power transformer, toroid, 750 VA, with 30V @ 25A secondary, 1182 Series
Hammond Manufacturing · 1182T30
Save 52%1182T60 — Power transformer, toroid, 1500 VA, with 60V @ 25A secondary, 1182 Series
Hammond Manufacturing · 1182T60
Save 52%1182T24 — Power transformer, toroid, 625 VA, with 24V @ 26.04A secondary, 1182 Series
Hammond Manufacturing · 1182T24
Save 52%1182T60P — Power transformer, toroid, 1500 VA, with 60V @ 25A secondary, 1182 Series
Hammond Manufacturing · 1182T60P
Save 52%1182T12 — Power transformer, toroid, 300 VA, with 12V @ 25A secondary, 1182 Series
Hammond Manufacturing · 1182T12