Hammond PF43000T12LG 169 CFM 115V AC Type 12 Filter Fan, Light Gray
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing PF43000T12LG.
224-955-1644Key Features
- 169 CFM unimpeded airflow; 142 CFM when paired with a PFA 40000 exhaust filter
- 115V AC supply, 40 W rated power per the series ordering table
- Maintains a UL Tested NEMA Type 12 seal; IP 55 (EN 60 529) when installed as specified
- UL Recognized to UL 508, category NITW2/8, File #E175229; CSA Approved fan motor
- Patented “Click & Fit” hardware-free installation in a 223 mm cutout
- Light Gray RAL 7035 ABS-FR housing, UL 94 V0 fire approved and self-extinguishing
- G 4 (DIN EN 779) Type 12 Filtermat with 0.91 filtration efficiency
- 252 x 252 x 113 mm, 1.67 kg, 46 dB (A) noise level, ball bearings
The PF43000T12LG is a 169 CFM filterfan from the PF GEN4 Type 12 range, built to move filtered air through electrical and control enclosures that house heat-generating equipment. It is the light gray (RAL 7035) 115V AC version of the PF 43000 fan, a good fit for panel builders, OEM engineers and maintenance teams who need to keep enclosure temperatures in check without compromising a NEMA Type 12 rating.
This version is wired for 115V AC and is rated at 40 W in the series ordering table. The installation manual lists 41 W / 38 W and 0.56 A / 0.47 A at 50/60 Hz for the 115V PF 43000. Power connection is by cage clamp terminals, and the manual states the connection may only be carried out by a qualified electrician.
The housing and guard are sprayed thermoplastic made from heat resistant ABS-FR that is UL 94 V0 fire approved and self-extinguishing. The fan runs on ball bearings and uses a NEMA Type 12 Filtermat of filter grade G 4 (DIN EN 779) with a filtration efficiency of 0.91. Outside dimensions are 252 x 252 x 113 mm (height x width x installation depth), with a unit weight of 1.67 kg and a noise level of 46 dB (A).
Unimpeded airflow is 169 CFM with a free-flow capacity of 188 W/K and a maximum static pressure of 112 Pa. Paired with a PFA 40000 exhaust filter (PFA40000LG in light gray), airflow in combination is 142 CFM and capacity is 69 W/K.
The patented “Click & Fit” design gives a hardware-free installation into a 223 mm cutout (+1/-0) for material up to 2 mm, or 224 mm for material over 2 mm and under 3 mm. Airflow direction can be reversed by removing four screws on the back, flipping the fan and refitting the screws. The PF43000T12LG is UL Recognized to UL 508 (category NITW2/8, File #E175229), its fan motor is CSA Approved, and it maintains a UL Tested NEMA Type 12 seal and IP 55 protection when installed as specified.
Ideal For
- Cooling NEMA Type 12 electrical and control enclosures
- Removing heat from enclosures housing heat-generating equipment
- Filtered forced-air ventilation of switch cabinets and housings
- 115V AC powered enclosure ventilation
Mounting
| Fitting Position | Any, horizontal airflow preferred |
| Installation Cutout | 223 mm +1/-0 (material up to 2 mm); 224 mm +1/-0 (material over 2 mm and under 3 mm) |
Overview
| Model | PF 43000 |
| Series | PF GEN4 Series, 94-169 CFM Filterfans |
| Description | 169 CFM Filter Fan, 115V N12 - Lt. Gray |
| Product Type | Filter fan (filterfan), NEMA Type 12 |
| Color Variant | Light Gray (RAL 7035); matching black version is PF43000T12BK |
| Short Description | 169 CFM FILTER FAN T12 |
Dimensions
| Weight | 1.67 kg |
| Outside Dimensions (H X W X Installation Depth) | 252 x 252 x 113 mm |
Electrical
| Power | 40 W |
| Wiring | Connection may only be carried out by a qualified electrician |
| Voltage | 115V AC |
| Connections | Cage clamp |
| Bearing Type | Ball bearings |
| Rated Power 50/60 Hz (Installation Manual) | 41 W / 38 W |
Accessories
| Optional Accessories | Exhaust filters, replacement filters, filterfan rainhoods (4/4X and 3R), thermostats; radiant heater, fan heater, thermostat, hygrostat |
| Matching Exhaust Filter | PFA40000LG (RAL7035 Light Gray) / PFA40000BK (RAL9011 Black) |
| Basic Accessories Parts Kit | Filter mat, user manual |
Identifiers
| UPC | 623980016139 |
| UNSPSC | 39121302 |
| Part Number | PF43000T12LG |
Packaging & Shipping
| Shipping Weight | 4.35 lbs (1.97 kg) |
Airflow & Performance
| Duty Cycle | 1 |
| Filter Material | NEMA Type 12 Filtermat |
| Airflow Direction | Reversible: remove 4 screws on back, flip fan over, replace screws to hand tightness |
| Unimpeded Airflow | 169 CFM |
| Filter Material Grade | G 4 (DIN EN 779) |
| Filtration Efficiency | 0.91 |
| Noise Level (EN ISO 3741) | 46 dB (A) |
| Max. Static Pressure (Airflow = 0 M3/h) | 112 Pa |
| Airflow In Combination (PF 43000 + PFA 40000) | 142 CFM |
| Capacity In Combination (PF 43000 + PFA 40000) | 69 W/K |
Construction & Finish
| Color | Light Gray (RAL 7035) |
| Construction | Housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 V0 |
| Installation | Patented “Click & Fit” hardware-free installation |
| Housing Material | ABS-FR plastic, UL 94 V0 fire approved, heat resistant |
Environmental & Protection
| Storage Temperature | -20 °C (-4 °F) to +70 °C (+158 °F) |
| Protection Condition | IP54 / IP55 / Type 12 protection is only guaranteed with vertical installation position and a non-destroyed foam gasket |
| System Of Protection | NEMA Type 12, IP 55 (EN 60 529), when installed as specified |
| Operating Temperature | -15 °C (-5 °F) to +55 °C (+131 °F) |
Compliance & Certifications
| UL | UL Recognized to UL 508, category NITW2/8, UL File #E175229 |
| Fan Motor | CSA Approved |
| NEMA Seal | Maintains a UL Tested NEMA Type 12 seal against enclosure |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Safety Protection | In accordance with DIN 31 001 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What airflow does the PF43000T12LG deliver?▾
Unimpeded airflow is 169 CFM. Used together with a PFA 40000 exhaust filter, airflow in combination is 142 CFM with a capacity of 69 W/K. Maximum static pressure is 112 Pa.
What power supply does it need?▾
This part number is the 115V AC version, rated at 40 W in the series ordering table. It connects through cage clamp terminals and should be wired by a qualified electrician.
Which exhaust filter should I pair with it?▾
The series ordering table lists PFA40000LG (light gray, RAL7035) and PFA40000BK (black, RAL9011) as the exhaust filters for this fan. The light gray one matches this unit's finish.
What size cutout does it need?▾
The installation cutout is 223 mm (+1/-0) for enclosure material up to 2 mm thick and 224 mm (+1/-0) for material over 2 mm and under 3 mm. Outside dimensions are 252 x 252 x 113 mm.
Can the airflow direction be reversed?▾
Yes. Per the application note for PF 11000 - PF 43000 fans, remove the four screws on the back surface, physically flip the fan over and replace the screws to hand tightness.
Does it keep my enclosure's Type 12 rating?▾
It maintains a UL Tested NEMA Type 12 seal against the enclosure and provides NEMA Type 12, IP 55 protection when installed as specified. The manual notes protection is only guaranteed in the vertical installation position with an undamaged foam gasket.
Related Products
Save 31%PF43000T12BK24 — 169 CFM Filter Fan, 24VDC N12 - Black
Hammond Manufacturing · PF43000T12BK24
Save 31%PF43000T12LG230 — 169CFM Filter Fan, 230V N12 - Lt. Gray
Hammond Manufacturing · PF43000T12LG230
Save 31%PF43000T12BK230 — 169 CFM Filter Fan, 230V N12 - Black
Hammond Manufacturing · PF43000T12BK230

PF43000T12LG24 — 169 CFM Filter Fan, 24VDC N12 - Lt. Gray
Hammond Manufacturing · PF43000T12LG24
Save 31%PF43000T12BK — 169 CFM Filter Fan, 115V N12 - Black
Hammond Manufacturing · PF43000T12BK