Hammond NWC18U2436SNBK 18U Sealed Wall-Mount Cabinet, Type 12 IP56
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- UL2416 Type 12 rated enclosure with 350 lb (158 kg) load rating in 14-gauge welded steel construction
- "N" version: no climate control and no cutouts of any kind - a fully solid, sealed enclosure
- Independently tested to IEC 60529 IP56 for dust ingress and powerful water jets
- 18U of 19" rack space: 32.00 in usable mounting height, 30.00 in usable depth with swing-out function
- Double-hinged design with concealed hinges gives dual front and rear access to equipment
- Two pairs of adjustable EIA-compliant tapped 10-32 rails, plus SCREW1032-50 starter hardware pack
- Seismic rated to 200 lb (90.72 kg) dynamic load, Ip = 1.5, per IBC 2018, CBC 2019, NBC 2018, ASCE 7-16/7-10
- RAL9005 Black powder coat (GREENGUARD Gold, TSCA, RoHS compliant); TAA compliant, made in Canada
The NWC18U2436SNBK is an 18U enclosed wall-mount rack cabinet built for network and industrial equipment that has to survive dust, dirt and washdown-adjacent conditions. It is the "N" configuration of the NWC Series: no climate control and no cutouts of any kind, so the enclosure ships as a fully solid, sealed box with a solid (non-window) door in RAL9005 Black. Integrators, plant electricians, automation engineers and facilities teams use it for IDF and edge computing drops where a standard indoor wall cabinet would not hold up.
Construction is 14-gauge welded steel (mild steel) with a powder coat finish that is GREENGUARD Gold, TSCA and RoHS compliant. Gasketed doors seal the enclosure against dust, dirt and dripping liquids, and the double-hinged cabinet design lets the centre section swing out so equipment can be reached from both front and rear. Concealed hinges, external mounting feet and a rear pan design support secure wall installation and cable entry, and dedicated bonding and grounding points are provided for proper bonding of all cabinet components.
Overall dimensions are 42.27 in high x 24.50 in wide x 36.22 in deep (1074 x 622 x 920 mm), with 18U of 19-inch rack space: 32.00 in usable mounting height and 30.00 in usable depth with the swing-out function (26.55 in rail-to-rail). Two pairs of adjustable, EIA-compliant tapped 10-32 mounting rails are included along with a starter hardware pack of SCREW1032-50 screws. The cabinet also allows power bar mounting without using rack U space.
NWC18U2436SNBK is UL2416 Type 12 rated with a 350 lb (158 kg) load rating, independently tested to IEC 60529 IP56, and seismic rated to 200 lb (90.72 kg) dynamic load (Ip = 1.5) per IBC 2018, CBC 2019, NBC 2018, ASCE 7-16 and ASCE 7-10. It meets PCI DSS requirements, is TAA compliant and is manufactured in Canada.
Ideal For
- Industrial environments with dust, dirt or water exposure
- Manufacturing, automation and processing facilities
- Edge computing and IDF deployments in harsh environments
- Critical infrastructure requiring UL2416 load rating with Type 12 protection
- Seismic-rated enclosure installations in regulated environments
Overview
| Series | NWC Series Environmental Wall-Mount Cabinet, Type 12, IP56 (350 lb) |
| Rack Type | Enclosed Wall Rack |
| Door Style | Solid door (included) |
| Rack Units | 18U |
| Load Rating | 350 lb (158 kg) per UL2416 |
| Part Number | NWC18U2436SNBK |
| Configuration | "N" Version - no climate control, no cutouts of any kind (solid enclosure) |
| Seismic Rating | 200 lb (90.72 kg) dynamic load (Ip = 1.5) |
| Short Description | 18U 24W 36D NWC SOLID |
Dimensions
| Overall Depth | 36.22 in (920 mm) |
| Overall Width | 24.50 in (622 mm) |
| Overall Height | 42.27 in (1074 mm) |
| Rail-to-Rail Depth | 26.55 in (674 mm) |
| Usable Mounting Depth | 30.00 in (762 mm) |
| Usable Mounting Height | 32.00 in (813 mm) |
| Nominal Size (H X W X D) | 36 in x 24 in x 36 in (914 mm x 610 mm x 914 mm) |
| Rack Mounting Height (18U) | 31.00 in (787 mm) |
| Maximum Equipment Depth (With Swing-out Function) | 30.00 in (762 mm) |
Electrical
| Bonding & Grounding | Dedicated bonding and grounding points for all cabinet components |
Identifiers
| UPC | 623980013589 |
| ECCN | EAR99 |
| UNSPSC | 43223306 |
| GTIN-14 | 00623980013589 |
| Tariff Code | 9403.10.0040 |
| Country Of Origin | CA |
| UPC W/o Check Digit | 62398001358 |
Rack Mounting
| Rail Type | Tapped 10-32 |
| Rack Standard | 19" rack compatible, EIA compliant |
| Cabinet Access | Double-hinged design with concealed hinges for front and rear access |
| Included Hardware | Starter hardware pack with SCREW1032-50 screws |
| 19" Mounting Width | 18.35 in (466 mm) |
| Power Bar Mounting | Power bar mounting without using 'U' space |
| Assembly Components | 24W 18U NWC Rear Assembly (1), Centre (1), Solid Door (1), 18U panel rails (4) |
| Mounting Rails Supplied | Two (2) pairs of adjustable 10-32 threaded rails (H1 Panel Rail 18U LH x2, RH x2) |
Packaging & Shipping
| Shipping Weight | 176 lbs (79.83 kg) |
Construction & Finish
| Finish | Black textured powder coat (GREENGUARD Gold, TSCA, RoHS compliant) |
| Material | Mild Steel |
| Paint Color | RAL9005 Black |
| Construction | 14-gauge welded steel |
| Wall Installation | External mounting feet and rear pan design for wall mounting and cable entry |
Environmental & Protection
| Sealing | Sealed enclosure with gasketed doors; protects against dust, dirt and dripping liquids |
| Enclosure Rating | UL2416 Type 12 |
| Ingress Protection | IP56, independently tested to IEC 60529 (dust ingress and powerful water jets) |
Compliance & Certifications
| PCI DSS | Meets PCI DSS compliance requirements |
| Standards | cULus, PCI, Zone 4, TAA-compliant |
| UL File # | E474597 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| USMCA Compliant | Yes |
| Seismic Standards | IBC 2018, CBC 2019, NBC 2018, ASCE 7-16, ASCE 7-10 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Does NWC18U2436SNBK include a fan, filter or air conditioner?▾
No. This is the "N" version, which comes without climate control and without cutouts of any kind - it is a solid, sealed enclosure. The "F" version adds rear and door filters compatible with fan kits, and the "A" version ships with a 900-1300 BTU DTS3021A115LG air conditioner inside the cabinet with cord.
How much equipment depth is available?▾
Usable mounting depth is 30.00 in (762 mm) as maximum equipment depth with the swing-out function, and rail-to-rail depth is 26.55 in (674 mm). Overall cabinet depth is 36.22 in (920 mm).
What door does this part number come with?▾
NWC18U2436SNBK has a solid door in RAL9005 Black. The window-door equivalent is NWC18U2436WNBK, and the light gray (RAL 7035) solid-door version is NWC18U2436SNLG.
How much weight can the cabinet support?▾
It is UL2416 Type 12 rated to a 350 lb (158 kg) load rating, and seismic rated to 200 lb (90.72 kg) dynamic load at Ip = 1.5 per IBC 2018, CBC 2019, NBC 2018, ASCE 7-16 and ASCE 7-10.
What rails and mounting hardware are supplied?▾
Two pairs of adjustable, EIA-compliant tapped 10-32 mounting rails are included, along with a starter hardware pack containing SCREW1032-50 screws for equipment installation.
Is this cabinet suitable for government and TAA-sensitive projects?▾
Yes. It is TAA compliant and manufactured in North America (country of origin CA), is USMCA, RoHS and REACH compliant, and carries ECCN EAR99.
Related Products
Save 35%NWC18U2436SFLG — 18U 24W 36D Nwc Solid Filters
Hammond Manufacturing · NWC18U2436SFLG
Save 35%NWC18U2436SNLG — 18U 24W 36D Nwc Solid
Hammond Manufacturing · NWC18U2436SNLG
Save 35%NWC18U2436SFBK — 18U 24W 36D Nwc Solid Filters
Hammond Manufacturing · NWC18U2436SFBK
Save 35%NWC18U2436WABK — 18U 24W 36D Nwc Window AC Unit
Hammond Manufacturing · NWC18U2436WABK
Save 35%NWC18U2436SALG — 18U 24W 36D Nwc Solid AC Unit
Hammond Manufacturing · NWC18U2436SALG