(224) 955-1644
Hammond ManufacturingAuthorized partner store
DTS3441CA230LG 230 V 20,840 BTU/h side-mount indoor enclosure air conditioner in light gray

Hammond DTS3441CA230LG 20,840 BTU/h 230V Indoor Enclosure Air Conditioner

Hammond Manufacturing|

MPN: DTS3441CA230LG

|

UPC: 623980111247

Available on Backorder
$5,545.06

Ships from and sold by A5 IT

Available on backorder — ships as soon as stock arrives

Freight Delivery · $409.99Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 20840 BTU/h (6103 W) at +95/+95 °F (+35/+35 °C)
  • 230V 50/60 Hz, 207-253V, 2674W, 11.82A running, 23A starting
  • Maintains NEMA 12 / IP 54; UL, cUL and CE
  • 57.20 x 15.80 x 16.10 in (1453 x 401 x 409 mm), 201.5 lbs
  • 1244 CFM internal and 565 CFM external airflow
  • Hot gas bypass valve and 3 mm condenser fin spacing
  • Filterless with built-in condensate evaporator
  • Gasket, mounting kit and drilling template included

The DTS3441CA230LG is a 230 V, 50/60 Hz indoor air conditioner from the DTS 20,000-25,000 BTU/H series, designed for side mounting on any enclosure surface where high capacity system cooling is required. It is suited to large control and automation enclosures in plants and facilities that run a 230 V supply.

This model is rated 20840 BTU/h (6103 W) at +95/+95 °F (+35/+35 °C). Closed loop cooling recirculates clean enclosure air without mixing it with contaminated ambient air, and the layout maximizes clearance between the warm inlet and cold outlet to reduce hot spots. High capacity fans move 1244 CFM internally and 565 CFM externally (unrestricted). The condenser has 3 mm fin spacing for protection against strongly contaminated and aggressive ambient air, and a hot gas bypass valve prevents evaporator freeze up while minimizing heavy inrush currents.

On 230 V it works across 207-253 V, consumes 2674 W, draws 11.82 A running with a 23 A starting current, and connects by terminal block. The R-134a system has a thermostat adjustable from +77 to +113 °F (+25 to +45 °C), factory set to +95 °F (+35 °C), accessible from inside the enclosure. Ambient limits are +46 °F (+8 °C) to +131 °F (+55 °C), and noise is 81 dB(A).

The unit measures 57.20 in (1453 mm) high, 15.80 in (401 mm) wide and 16.10 in (409 mm) deep and weighs 201.5 lbs (91.4 kg). The galvanized sheet steel case is finished in RAL7035 light gray. The DTS3441CA230LG maintains the enclosure's NEMA 12 / IP 54 rating with UL, cUL and CE approvals, and it is filterless with a built-in condensate evaporator. Gasket, mounting kit, drilling template and condensate drain hose and clamp are included.

Ideal For

  • High capacity cooling for large indoor control enclosures
  • Side-mounted cooling for NEMA 12 cabinets on 230 V
  • Reducing hot spots in densely packed enclosures
  • Cooling enclosures exposed to contaminated ambient air

Cooling

Filter MatFilterless
RefrigerantR-134a
Cooling MethodClosed loop - clean enclosure air recirculated without mixing with ambient air
Air CirculationContinuous, from high capacity fans; maximum clearance between warm inlet and cold outlet
Condensate DischargeCondensate evaporator (built in)
Hot Gas Bypass ValvePrevents evaporator freeze up while minimizing heavy inrush currents
Condenser Fin Spacing3 mm, for protection against strongly contaminated and aggressive ambient air
Air Capacity (Unrestricted)Internal circulation 1244 CFM; external circulation 565 CFM
Cooling Capacity (+95/+95 F, +35/+35 C)20840 BTU/h (6103 Watts)

Controls

ThermostatAccessible from inside enclosure
DiagnosticsSelf-diagnostics on startup; fault indication via LED light
Door ContactProvision for door contact allowing power down when enclosure door is opened
Factory Setting+95 °F / +35 °C
Adjustable Control Range+77 to +113 °F / +25 to +45 °C

Overview

SeriesDTS Series - 20,000-25,000 BTU/H Indoor Air Conditioner, Type 12, Side Mounting
Part NumberDTS3441CA230LG
Long DescriptionAir Conditioner 12-20000 BTU 230V LG
Short DescriptionAC UNIT 12-20000BTU230V-N12 LG
Optional AccessoriesRemote door switches, filter kits, gasket kits, water condensate evaporator, condensate bottle

Dimensions

Depth16.10 in (409 mm)
Width15.80 in (401 mm)
Height57.20 in (1453 mm)
Unit Weight201.5 lbs (91.4 kg)
Size H X W X D57.2 in x 15.8 in x 16.1 in (1,453 mm x 401 mm x 409 mm)

Electrical

Line CordTerminal Block
Running Amps11.82A
Rated Voltage230V 50/60 Hz
Starting Current23A
Power Consumption2674W
Range Of Operation207-253V
EMI/RFI SuppressionMeets CE

Identifiers

UPC623980111247
UNSPSC39121301

Installation

MountingSide mounting on any enclosure surface
Drilling TemplateDrilling Template DTS 34/36x1, part number 885407019 (spare-part no. 18380000032), 1:1 printable format
Drilling Template Overall Dimensions1440 mm (56.69 in) x 350 mm (13.78 in)

Packaging & Shipping

IncludedGasket, mounting kit and template for enclosure cutout and drilling; condensate drain hose and clamp
Shipping Weight201.5 lbs (91.40 kg)

Construction & Finish

FinishRAL7035 Light Gray (LG)
Exterior CaseGalvanized sheet steel
Alternate Finish (GY)ANSI 61 Gray

Environmental & Protection

IP RatingIP 54
Noise Level81 dB(A)
Max Ambient Air Temp+131 °F (+55 °C)
Min Ambient Air Temp+46 °F (+8 °C)

Compliance & Certifications

ApprovalsUL, cUL and CE
NEMA RatingMaintains enclosure's NEMA 12 rating (Enclosures IP 54 / Nema 12)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the cooling capacity of the DTS3441CA230LG?▾

20840 BTU/h (6103 Watts) at +95/+95 °F (+35/+35 °C).

What electrical supply does it need?▾

230V 50/60 Hz, with an operating range of 207-253V. Running current is 11.82A and starting current is 23A; connection is by terminal block.

What are its dimensions?▾

57.20 in (1453 mm) high, 15.80 in (401 mm) wide and 16.10 in (409 mm) deep.

Does it keep the enclosure NEMA 12?▾

Yes. It maintains the enclosure's NEMA 12 rating and is IP 54, with UL, cUL and CE approvals.

What airflow does it provide?▾

Unrestricted air capacity is 1244 CFM internal circulation and 565 CFM external circulation.

What is included for installation?▾

A gasket, mounting kit and template for the enclosure cutout and drilling are included, plus a condensate drain hose and clamp.