(224) 955-1644
Hammond ManufacturingAuthorized partner store
269AAX 66 VA enclosed vertical-mount plate and heater power transformer

Hammond 269AAX 66VA 200V C.T. Plate Transformer, 6.3V Heater

Hammond Manufacturing|

MPN: 269AAX

|

UPC: 623980397863

In Stock
$74.05

Ships from and sold by A5 IT

Ground Shipping · $19.62Arrives by Monday, Oct 26
Order within 1h 54m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 66 VA plate and heater power transformer
  • 200V C.T. @ 250ma. high voltage secondary
  • 6.3V C.T. @ 2.5A heater winding
  • 117 VAC 60 Hz primary, with 115V (white-gray) and 125V (white-black) taps
  • 22AWG leads, 6 in out, stripped 0.5 in
  • Hipot 2000V primary-secondaries, 1500V primary-core
  • Enclosed, 4 hole vertical (X) chassis mount; CSA certified (209651)
  • RoHS and REACH compliant

The 269AAX is a 66 VA high voltage (plate) and filament power transformer from the 200 Series, listed with a 117 VAC, 60 Hz primary, for builders who need a 200V center-tapped plate supply at 250ma. plus a 6.3V heater winding.

The high voltage secondary provides 200V C.T. at 250ma., and the heater winding provides 6.3V C.T. at 2.5A. The drawing labels the primary taps white-gray for 115V 60Hz and white-black for 125V. Electrical test data at 125V, 60Hz (white-black) lists 186mA excitation current and no-load voltages of 114.6V (white-gray), 213.3V (red-red), 106.7V (each half of the HV winding), 6.757V (green-green) and 3.378V (each half of the heater), all ±20%. DC resistances are 5.557 ohms (white-gray), 6.134 ohms (white-black), 24.90 ohms (red-red) and 95 mOhms (green-green), ±20%.

Hipot ratings are 1500V primary-core and 2000V between all other windings and core (60Hz, 1 sec). All leads are 22AWG, 6 in out and stripped 0.5 in minimum. It weighs 2.25 lbs ±4% per the drawing (3 lbs shipping) and is marked made in Canada.

As a 200 Series part it is an enclosed, 4 hole, chassis mount design with minimum 6 in leads and Class A insulation (105 degrees C). Units can be run full wave bridge or full wave C.T., are hi-pot tested at 2,000V RMS, and follow a conservative design that is CSA certified (209651).

The primary offers two input choices. For 115 VAC input, use the white and gray wires and tape the black wire. If line voltage runs high (roughly 125V) and the secondary voltage reads too high, use the white and black wires and tape the gray wire. Never connect power to both the gray and black wires, as instantaneous destruction of the transformer will result.

Table dimensions are A 2.50 in (64 mm), B 2.75 in (70 mm), C 3.06 in (78 mm), D 2.00 in (51 mm) and F 1.69 in (43 mm) with 0.20 x 0.38 in (5 x 10 mm) slots; the drawing shows 1.72 in for F and Ø0.203 x 0.375 in slots. The part is RoHS and REACH compliant.

Ideal For

  • Low-voltage, higher-current B+ supplies for tube circuits
  • Tube preamp and small amplifier builds with 6.3V heaters
  • Full wave bridge or C.T. rectified plate supplies

Overview

Series200 Series (High Voltage (Plate) & Filament - 32 VA to 454 VA)
Product TypeHigh voltage (plate) and filament power transformer
Manufacturer Short Description117V, 60 Hz

Dimensions

Dimension A2.50 in (64 mm)
Dimension B2.75 in (70 mm)
Dimension C3.06 in (78 mm)
Dimension D2.00 in (51 mm)
Dimension F (Drawing)1.72 in ±0.063
Mounting Slot (Drawing)Ø0.203 in x 0.375 in ±0.015
Dimension F (Series Table)1.69 in (43 mm)
Mounting Slot G (Series Table)0.20 in x 0.38 in (5 mm x 10 mm)

Electrical

CautionNever connect power to both the Gray & Black wire
Filament #26.3V C.T. @ 2.5A (GRN - GRN/YEL - GRN)
Hi-Pot Test2,000V RMS
Power Rating66 VA
DCR GRN - GRN95 mOhms ±20%
DCR RED - RED24.90 ohms ±20%
DCR WHT - BLK6.134 ohms ±20%
DCR WHT - GRY5.557 ohms ±20%
Primary Frequency60 Hz
115 VAC Input WiringUse White & Gray wires, tape the Black wire
125 VAC Input WiringUse White & Black wires, tape the Gray wire (for roughly 125V line voltage)
Hipot Primary - Core1500V, 60Hz, 1 SEC
Primary Taps (Drawing)WHT - GRY: 115V 60Hz; WHT - BLK: 125V
Rectifier ConfigurationCan be run full wave bridge or full wave C.T.
Excitation Current (Iex)186mA @ 125V, 60Hz, WHT - BLK
Hipot Secondaries - Core2000V, 60Hz, 1 SEC
No-Load Voltage GRN - GRN6.757V ±20%
No-Load Voltage RED - RED213.3V ±20%
No-Load Voltage WHT - GRY114.6V ±20% (@ 125V, 60Hz, WHT - BLK)
Hipot Primary - Secondaries2000V, 60Hz, 1 SEC
Hipot Secondary - Secondary2000V, 60Hz, 1 SEC
Primary Voltage (Series Table)117 VAC
AC High Voltage Secondary (R.M.S.)200V C.T. @ 250ma. (RED - RED/YEL - RED)
No-Load Voltage GRN - GRN/YEL = GRN/YEL - GRN3.378V ±20%
No-Load Voltage RED - RED/YEL = RED/YEL - RED106.7V ±20%

Identifiers

UPC623980397863
UNSPSC39121301
Country Of OriginCanada (marked MADE IN CANADA)

Packaging & Shipping

Shipping Weight3 lbs (1.36 kg)
Weight (Drawing)2.25 lbs ±4%

Construction & Finish

Lead DetailsAll leads 22AWG, 6 in out and stripped 0.5 in minimum
Mounting TypeVertical ("X" mounting)
Production NoteRunning change made to the primary winding effective with August 2009 production
Enclosure / MountingEnclosed, 4 hole, chassis mount

Environmental & Protection

Insulation ClassClass A (105 degrees C)

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
CSA CertificationCSA certified (209651)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What primary voltage does the 269AAX use?▾

The series table lists 117 VAC, 60 Hz; the drawing labels white-gray as 115V 60Hz and white-black as 125V. Never power both gray and black.

What are the secondary ratings?▾

200V C.T. at 250ma. on the high voltage winding and 6.3V C.T. at 2.5A on the heater winding.

What lead gauge and length are used?▾

All leads are 22AWG, 6 in out and stripped 0.5 in minimum.

What hipot ratings apply?▾

1500V primary to core and 2000V primary to secondaries, secondary to secondary and secondaries to core, each 60Hz for 1 second.

How much does it weigh?▾

The drawing lists 2.25 lbs ±4%; the shipping weight is 3 lbs (1.36 kg).