Hammond 263AX 32VA 200V C.T. Plate Transformer, 5V Filament
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 32 VA high voltage and filament power transformer
- 115 VAC, 60 Hz primary with 125V input option
- 200V C.T. @ 115ma. high voltage secondary
- 5V @ 2A filament winding
- Enclosed, 4 hole vertical (X) chassis mount
- Class A insulation (105 degrees C), hi-pot tested at 2,000V RMS
- CSA certified (209651); RoHS and REACH compliant
The 263AX is a 32 VA high voltage (plate) and filament power transformer from the 200 Series, the smallest VA rating in the vertical "X" mounting table. It is intended for builders and technicians powering small tube amplifiers, preamps and other valve circuits from a North American supply.
The primary is rated 115 VAC at 60 Hz. The A.C. high voltage secondary delivers 200V C.T. at 115ma. R.M.S., and a single filament winding provides 5V at 2A; there is no second filament winding.
As a 200 Series part it is an enclosed, 4 hole, chassis mount design with minimum 6 in leads and Class A insulation (105 degrees C). Units can be run full wave bridge or full wave C.T., are hi-pot tested at 2,000V RMS, and follow a conservative design that is CSA certified (209651).
The primary offers two input choices. For 115 VAC input, use the white and gray wires and tape the black wire. If line voltage runs high (roughly 125V) and the secondary voltage reads too high, use the white and black wires and tape the gray wire. Never connect power to both the gray and black wires, as instantaneous destruction of the transformer will result.
Dimensions are A 1.88 in (48 mm), B 2.44 in (62 mm), C 2.50 in (64 mm), D 1.50 in (38 mm) and F 1.56 in (40 mm), with mounting slots of 0.19 x 0.31 in (5 x 8 mm). Shipping weight is 1.4 lbs (0.64 kg). The 263AX carries UPC 623980274201 and is RoHS and REACH compliant.
Ideal For
- Low-power tube preamp power supplies
- Small tube amplifier builds with a 5V rectifier filament
- Replacement plate transformer for 115V/60Hz equipment
Overview
| Series | 200 Series (High Voltage (Plate) & Filament - 32 VA to 454 VA) |
| Product Type | High voltage (plate) and filament power transformer |
| Manufacturer Description | Transformer, high voltage, 32VA, primary 115VAC, HV secondary 200V C.T. @ 115ma. |
| Manufacturer Short Description | POWER TX |
Dimensions
| Dimension A | 1.88 in (48 mm) |
| Dimension B | 2.44 in (62 mm) |
| Dimension C | 2.50 in (64 mm) |
| Dimension D | 1.50 in (38 mm) |
| Dimension F | 1.56 in (40 mm) |
| Mounting Slot G | 0.19 in x 0.31 in (5 mm x 8 mm) |
Electrical
| Caution | Never connect power to both the Gray & Black wire |
| Filament #1 | 5V @ 2A |
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 32 VA |
| Primary Voltage | 115 VAC |
| Primary Frequency | 60 Hz |
| 115 VAC Input Wiring | Use White & Gray wires, tape the Black wire |
| 125 VAC Input Wiring | Use White & Black wires, tape the Gray wire (for roughly 125V line voltage) |
| Rectifier Configuration | Can be run full wave bridge or full wave C.T. |
| AC High Voltage Secondary (R.M.S.) | 200V C.T. @ 115ma. |
Identifiers
| UPC | 623980274201 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 1.4 lbs (0.64 kg) |
Construction & Finish
| Leads | Minimum 6 in long leads |
| Mounting Type | Vertical ("X" mounting) |
| Production Note | Running change made to the primary winding effective with August 2009 production |
| Enclosure / Mounting | Enclosed, 4 hole, chassis mount |
Environmental & Protection
| Insulation Class | Class A (105 degrees C) |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CSA Certification | CSA certified (209651) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What voltages does the 263AX supply?▾
A 200V C.T. high voltage secondary at 115ma. and a 5V filament at 2A.
Can it run from 125V line voltage?▾
Yes. Use the white and black wires and tape the gray wire for roughly 125V input; for 115V use white and gray and tape black. Never power both gray and black.
Can it be used with a bridge rectifier?▾
200 Series units can be run full wave bridge or full wave C.T.
What are the mounting dimensions?▾
A 1.88 in, B 2.44 in, C 2.50 in, D 1.50 in, F 1.56 in, with 0.19 x 0.31 in slots.
Is it certified?▾
The 200 Series is CSA certified (209651); the 263AX is also RoHS and REACH compliant.
Related Products
Save 52%263CX — Transformer, high voltage, 116VA, primary 115VAC, HV secondary 360V C.T. @ 287ma.
Hammond Manufacturing · 263CX
Save 52%269AAX — 117V, 60 Hz
Hammond Manufacturing · 269AAX
Save 52%269AX — Transformer, high voltage, 40VA, primary 115VAC, HV secondary 250V C.T. @ 115ma.
Hammond Manufacturing · 269AX
Save 52%269BX — Transformer, high voltage, 38VA, primary 115VAC, HV secondary 300V C.T. @ 86ma.
Hammond Manufacturing · 269BX
Save 52%269EX — Transformer, high voltage, 43VA, primary 115VAC, HV secondary 380V C.T. @ 71ma.
Hammond Manufacturing · 269EX