224-955-1644Key Features
- 225 VA toroid with dual 30 V secondaries
- 60 V C.T. @ 3.75 A in series; 30 V @ 7.5 A in parallel
- Dual 117/234 VAC primary, 50/60 Hz
- Potted centre, 4.97 in (126 mm) OD x 1.90 in (48 mm) high
- 1/4-20 x 2.50 in centre bolt with bottom rubber pad
- 4,000 V RMS Hi-Pot; CSA, UL recognized, CE
- Minimum 8 in flexible leads
The 182F30 is a 225 VA toroidal power transformer, listed as TOROID, 225VA, 50HZ, 30/30V. Its dual 30 V secondaries deliver 60 V center-tapped at 3.75 A in series or 30 V at 7.5 A in parallel, fed from a dual 117/234 VAC, 50/60 Hz primary. It is a strong fit for amplifier and DC power supply builders who want a low profile, cool-running toroid.
According to the specification sheet, the 182 Series will soon be discontinued as a stocked series, available while quantities last, and has been replaced with the 1182 Series.
The 182F30 has a potted centre for added mounting strength. It measures 4.97 in (126 mm) in outside diameter and 1.90 in (48 mm) high and mounts with a 1/4-20 centre bolt 2.50 in (64 mm) long. Units of 225 VA and larger are supplied with one bottom rubber insulating pad and mounting hardware (the table lists bottom rubber washer only). Weight is 4.96 lbs in the series table; shipping weight is 5 lbs (2.27 kg).
Flexible leads are at least 8 in long. Each unit is Hi-Pot tested at 4,000 V RMS between primary and secondary and is CSA certified to C22.2 #66 (file 209651), UL recognized to UL506 (file E207860) and CE certified to IEC950; the part is RoHS and REACH compliant. Because toroids can draw heavy inrush current, fit a slow-blow fuse, time delayed breaker or soft start on the supply line.
Ideal For
- Audio amplifier power supplies
- 30 V or 60 V C.T. rectified DC supplies
- Dual-mains equipment power
Mounting
| Potted Center | Yes |
| Supplied With | One bottom rubber insulating pad and mounting hardware (225VA and larger) |
| Toroid Center | Potted |
| Mounting Style | Center single hole mounting |
| Mounting Hardware Length | 2.50 in (64 mm) |
| Mounting Hardware Thread | 1/4-20 |
| Top Steel Mounting Washer With Top & Bottom Rubber Washer | Bottom Rubber Washer Only |
Overview
| Series | 182 Series - Toroidal L.V., Chassis Mount (15 VA to 1500 VA) |
| Part Number | 182F30 |
| Availability Note | Series will soon be discontinued as a stocked series; available while quantities last; replaced with 1182 Series |
| Short Description | TOROID, 225VA, 50HZ, 30/30V |
Dimensions
| Height | 1.90 in (48 mm) |
| Outside Diameter | 4.97 in (126 mm) |
Electrical
| Primary | Dual 117/234 VAC, 50/60 Hz |
| Windings | Designed to have all windings engaged |
| Hi-Pot Test | 4,000V RMS between primary & secondary |
| Power Rating | 225 VA |
| Primary Wiring | 117 V: parallel connection; 234 V: series connection |
| Inrush Current Guidance | Consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line |
| Dual Or Single Secondary | Dual |
| Secondary (RMS) - Series | 60V C.T. @ 3.75A |
| Secondary (RMS) - Parallel | 30V @ 7.5A |
Identifiers
| UPC | 623980272368 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 5 lbs (2.27 kg) |
| Weight (Series Table) | 4.96 lbs |
Construction & Finish
| Leads | Minimum 8" long flexible leads |
| Design | Toroidal - low profile, lightweight, cool running |
Compliance & Certifications
| CE | Certified to IEC950 |
| UL | Recognized to UL506 - UL file #E207860 |
| CSA | Certified to C22.2 #66 - CSA file #209651 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What outputs does the 182F30 provide?▾
60 V C.T. at 3.75 A with secondaries in series, or 30 V at 7.5 A in parallel.
Does the 182F30 have a potted center?▾
Yes, the series table lists a potted center for this 225 VA part.
What mounting hardware is included?▾
A 1/4-20 bolt 2.50 in long and one bottom rubber insulating pad, as supplied with 225 VA and larger units.
What are the dimensions?▾
4.97 in (126 mm) outside diameter and 1.90 in (48 mm) high.
What does it weigh?▾
4.96 lbs per the series table; 5 lbs (2.27 kg) shipping.
Related Products

182F240 — Toroid, 80VA, 50HZ, 240V
Hammond Manufacturing · 182F240
Save 52%182G110 — Toroid, 50VA, 50HZ, 110/110V
Hammond Manufacturing · 182G110
Save 52%182F22 — Replace With 1182F22
Hammond Manufacturing · 182F22
Save 52%182G117 — Toroid, 50VA, 50HZ, 117/117V
Hammond Manufacturing · 182G117
Save 52%182F18 — Replace With 1182F18
Hammond Manufacturing · 182F18