Hammond 1589H70D124 70 in 24-Outlet Vertical PDU, 20A L5-20P
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 70.00 in (1778 mm) vertical strip with 24 NEMA 5-20R outlets rated 20 A, 125 VAC
- On/off rocker power switch plus 20 A resettable circuit breaker
- Integral 15 ft 12/3 SJT heavy-duty 12 gauge cord with molded NEMA L5-20P locking plug
- Anodized aluminum extrusion case with ABS plastic ends, natural finish, low-profile slim design
- Mounting bracket kit with hardware included; extra kits available as P/N 1585CLIP
- UL/cUL Listed to UL1363 and CSA C22.2 No. 308-14, UL File # E166039
- Operating temperature -20 °C to +60 °C; RoHS, REACH and TAA compliant
- 1 in square receptacles equally spaced over the length of the strip
The 1589H70D124 is a 70 in (1778 mm) vertical basic PDU from the 1589H-T Series, built for IT, AV and facilities teams that need dense 120 V power distribution alongside rack-mounted equipment. It carries 24 heavy-duty black NEMA 5-20R receptacles rated 20 A at 125 VAC, a 20 A resettable circuit breaker and an on/off rocker power switch, and it is fed by an integral 15 ft 12/3 SJT cord with a molded NEMA L5-20P locking plug.
Construction is a low-profile anodized aluminum extrusion with ABS plastic end caps, giving a rugged but light-weight strip in a natural finish (the series is available in black finish upon request). The 1 in square receptacles are equally spaced over the length of the strip, and the heavy 12 gauge cord is suited to the -20 °C to +60 °C operating temperature range.
Overall assembly length is 1789.86 mm (70.467 in) with the receptacle pattern spanning 1783.08 mm (70.200 in); the strip stands 41.05 mm (1.616 in) tall and 29.18 mm (1.149 in) deep as viewed from the end. Shipping weight is 7.1 lbs (3.22 kg).
A mounting bracket kit with hardware is included, so 1589H70D124 can be installed vertically in server cabinets, wall mount cabinets and open frame racks, or horizontally above a work bench. Additional hardware is available as P/N 1585CLIP. Note that outlet strips cannot be used between the front and rear panel rails of rack cabinets, as the strip and equipment plugs will interfere with mounted equipment and accessories; allow sufficient depth behind the rear panel rails for vertical mounting to the struts.
The series is UL/cUL Listed to UL1363 and CSA C22.2 No. 308-14 (UL File # E166039), RoHS and REACH compliant, USMCA compliant, TAA-compliant for federal GSA schedule purchases within the USA, and manufactured in North America.
Ideal For
- Vertical power distribution in server cabinets
- Wall mount cabinet power feeds
- Open frame and relay rack installations
- Horizontal mounting above a work bench
- Federal GSA schedule / TAA-compliant procurement
Overview
| Series | 1589H-T Series (20A | 120V Single-Phase | 5-15/5-20R Outlets) |
| Description | 20A 24 OUTLET 15' TW LCK 70" L |
| Part Number | 1589H70D124 |
| Outlet Strip Type | Vertical Basic PDU |
| Accessories Included | Mounting Bracket Kit with Hardware |
| Additional Hardware Kit | 1585CLIP (Vertical Outlet Strip Mounting Clip Kit) |
| Pilot Light Equivalent Part No. | 1589T70D124 |
Dimensions
| Height | 41.05 mm [1.616 in] |
| Strip Length | 70.00 in (1778 mm) |
| Depth (View From End) | 29.18 mm [1.149 in] |
| Overall Assembly Length | 1789.86 mm [70.467 in] |
| Receptacle Pattern Length | 1783.08 mm [70.200 in] |
Electrical
| Phase | Single-Phase |
| Metered | No |
| Cord Type | Heavy duty 12 gauge, 12/3 SJT with integral molded plug |
| Plug Type | NEMA L5-20P locking |
| Cord Length | 15 ft |
| Outlet Type | 5-20R (NEMA 5-20R, Single T-Slot), 20A/125V |
| Switch Type | On/Off Rocker Switch |
| Cord Included | Yes |
| Rated Current | 20 A |
| Rated Voltage | 120VAC |
| Shielded Cord | No |
| Drawing Rating | 125 VAC, 60 Hz, 20 Amps |
| Hospital Grade | No |
| Circuit Breaker | 20 Amp resettable circuit breaker |
| Rotated Outlets | No |
| Receptacle Color | Heavy-duty black |
| Surge Protection | No |
| Number Of Outlets | 24 |
| Receptacle Size / Spacing | 1 in square, equally spaced over the length of the strip |
| Outlets (Front) / Outlets (Rear) | 7 / 0 |
| Total Outlets (Manufacturer Attribute) | 7 |
Identifiers
| UPC | 623980304786 |
| UNSPSC | 39121710 |
| GTIN-14 | 00623980304786 |
| UPC W/o Check Digit | 62398030478 |
Packaging & Shipping
| Tariff Code | 8537.10.9170 |
| Manufacturing | Manufactured in North America |
| Shipping Weight | 7.1 lbs (3.22 kg) |
| Country Of Origin | CA |
Construction & Finish
| Color | Natural (black finish available upon request) |
| Design | Low-profile slim design, rugged light weight aluminum |
| End Caps | ABS Plastic |
| Case Material / Finish | Anodized aluminum extrusion |
Environmental & Protection
| Operating Temperature | -20 °C to +60 °C |
Compliance & Certifications
| ECCN | EAR99 |
| Standards | cULus, TAA-compliant |
| UL File # | E166039 |
| RoHS Compliant | Yes |
| UL/cUL Listing | UL1363 and CSA C22.2 No. 308-14 |
| REACH Compliant | Yes |
| USMCA Compliant | Yes |
| Drawing Approvals | CSA Certified Standards C22.2 (No. 21-95, 42-99); UL Listed Standard UL1363 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
How many outlets does the 1589H70D124 have and what type are they?▾
The series ordering table and the part drawing show 24 NEMA 5-20R receptacles rated 20A/125V. The receptacles are 1 in square, black, and equally spaced over the 70 in length.
What plug and cord come with this PDU?▾
It includes an integral 15 ft heavy duty 12 gauge 12/3 SJT cord with a molded NEMA L5-20P locking plug.
Does it have a switch or a pilot light?▾
1589H70D124 is the on/off switch version, with an on/off rocker power switch and a 20 A resettable circuit breaker. The equivalent pilot light model is 1589T70D124.
Is mounting hardware included?▾
Yes, a mounting bracket kit with hardware is included. Additional hardware kits can be ordered as P/N 1585CLIP.
Where should this strip be mounted in a rack cabinet?▾
Per the series notes, outlet strips cannot be used between the front and rear panel rails, because the strip and equipment plugs will interfere with mounted equipment and accessories. Allow sufficient depth behind the rear panel rails for vertical mounting to the struts.
Is it metered or surge protected?▾
No. This is a basic PDU: surge protection is not included and the unit is not metered. It is also not hospital grade and the cord is not shielded.
Related Products
Save 35%1589H70D1 — 20A 10 Outlet 15' Tw Lck 70" L
Hammond Manufacturing · 1589H70D1
Save 35%1589H70F1 — 20 Amp P/B, 70" Long, 10 Recp
Hammond Manufacturing · 1589H70F1
Save 35%1589H70C124 — 20A 24 Outlet 6' Tw Lck 70" L
Hammond Manufacturing · 1589H70C124
Save 35%1589H70F124 — 20A 24 Outlet 6' Straight 70"L
Hammond Manufacturing · 1589H70F124
Save 35%1589H70C1 — 70" 20AMP P-Bar W/Swich Tw Lck
Hammond Manufacturing · 1589H70C1