Hammond 1182S15 300 VA Toroid Transformer, 30V CT or 15V Output
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Two 15V @ 10A windings: 30V C.T. @ 10A or 15V @ 20A
- 5.00% voltage regulation at 300 VA
- #12 TEW secondary leads for the 20 A parallel rating
- 1/4-20 x 2.50" bolt, lock washer, nut and washers supplied
- Dual 117/234 VAC, 50/60 Hz primary (parallel for 117 V, series for 234 V)
- Class B (130 degree C) materials; 4,000 VAC RMS hi-pot primary to secondary
- UL recognized (file #E207860) and CSA certified (file #209651)
- Toroid core: low profile, lightweight, cool running, low stray flux (low EMI)
The 1182S15 is a 300 VA toroid power transformer with two 15 V secondaries of 10 A each. In series it delivers 30V C.T. @ 10A and in parallel 15V @ 20A. It suits engineers building 15 V or 30 V center-tapped supplies on 117 VAC or 234 VAC mains.
The drawing specifies #20 TEW primary leads and #12 TEW secondary leads, 8"-9" long and stripped 0.5" minimum; secondaries are RED-BLU and GRY-YEL. Listed regulation is 5.00% with dimension reference H. The open-center toroid is supplied with two 0.062" x 3.75" OD rubber washers, one 16GA x 3.56" OD steel mounting washer and a 1/4-20 bolt 2.50" long with lock washer and hex nut. Shipping weight is 5.75 lbs (2.61 kg).
Every transformer in the 1182 series is manufactured using Class B (130 degree C) materials and hi-pot tested at 4,000 VAC RMS between primary and secondary. The series is UL recognized to UL 5085-1 and UL 5085-2 (UL file #E207860), CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (CSA file #209651), and self-declared as evaluated to applicable sections of IEC/EN61558-1 and IEC/EN61558-2-4. This part is listed as RoHS and REACH compliant.
Wiring is straightforward: the primaries go in parallel for 117 VAC operation or in series for 234 VAC, at 50 or 60 Hz, and a connection sheet ships with the unit. All windings should be engaged (series or parallel) or the unit connected as an autotransformer. Because of the toroid's magnetic properties, inrush at switch-on can sometimes blow a fuse or trip a breaker, although the overload rarely lasts longer than half a cycle; the manufacturer advises a slow-blow fuse, time-delay breaker or soft-start circuitry.
Ideal For
- 15 V or 30 V center-tapped supplies at 300 VA
- Equipment built for 117 VAC or 234 VAC mains
- Equipment for both 117 VAC and 234 VAC supplies (global use)
- Designs needing low stray magnetic flux (low EMI) in a low-profile package
Overview
| Series | 1182 Series - Toroid Power Transformers, 15 VA to 1500 VA |
| Replaces | Older 182 Toroid Series |
| Description | Power transformer, toroid, 300 VA, with 15V @ 20A secondary, 1182 Series |
| Part Number | 1182S15 |
| Power Rating | 300 VA |
| Product Type | Power transformer, toroid |
| Toroid Center | Open |
| Secondary Type | Dual |
| Short Description | TOROID, 300VA, 50/60HZ, 15/15V |
| Dimension Reference | H |
Electrical
| Polarity | Additive (BLK, BRN, RED and GRY) |
| Frequency | 50/60 Hz |
| Primary Voltage | Dual 117/234 VAC |
| Primary Connection | 117 VAC: parallel connection; 234 VAC: series connection |
| Voltage Regulation | 5.00% |
| Winding Connection | All windings engaged (series or parallel connected) or connected as an autotransformer |
| Inrush Current Note | Consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line |
| Secondary (RMS) - Series | 30V C.T. @ 10A |
| Primary Windings (Drawing) | 2x 117V BLK-WHT, BRN-ORN |
| Secondary (RMS) - Parallel | 15V @ 20A |
| Secondary Windings (Drawing) | 2x 15V @ 10.0A RED-BLU, GRY-YEL |
| Hi-Pot Test, Primary - Primary | 600V, 60Hz, 1 sec |
| Secondary No-Load Voltage Test | @ 117V, 60Hz: BLK & BRN to WHT & ORN; or @ 234V, 50Hz: BLK to ORN (connect BRN & WHT) |
| Hi-Pot Test, Primary - Secondary | 4000V, 60Hz, 1 sec |
| Hi-Pot Test, Secondary - Secondary | 600V, 60Hz, 1 sec |
| Voltage Regulation (Part Page, Rounded) | 5% |
| Hi-Pot Test, Primary - Secondary (Series Spec) | 4,000 VAC RMS |
Identifiers
| UPC | 623980531748 |
| UNSPSC | 39121301 |
Leads & Wiring
| Lead Length | Minimum 8" long flexible leads |
| Connection Sheet | Included with transformer |
| Primary Lead Wire | #20 TEW |
| Secondary Lead Wire | #12 TEW |
| Primary Lead Colours | BLK-WHT (Primary #1), BRN-ORN (Primary #2) |
| Secondary Lead Colours | RED-BLU (Secondary #1), GRY-YEL (Secondary #2) |
| Lead Length & Strip (Drawing) | All leads out 8"-9" and stripped 0.5" min. |
Mounting Hardware
| Supplied Hardware 1 | Two 0.062" T x 3.75" OD rubber washers |
| Supplied Hardware 2 | One 16GA x 3.56" OD steel mounting washer |
| Supplied Hardware 3 | One 1/4-20 bolt 2.50" long with a lock washer and 1/4-20 hex nut |
Packaging & Shipping
| Shipping Weight | 5.75 lbs (2.61 kg) |
| Weight (Drawing) | 6.02 lbs +/- 4% |
| Country Of Origin | Canada |
Construction & Finish
| Core | Toroidal |
| Toroid Benefits | Low profile, lightweight, cool running / high efficiency, low stray magnetic flux leakage (low EMI) |
| Insulation Class | Class B (130 degree C) materials |
Compliance & Certifications
| UL | UL recognized to UL 5085-1 and UL 5085-2, UL file #E207860 |
| CSA | CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6, CSA file #209651 |
| IEC/EN | Self-declared evaluated to applicable sections of IEC/EN61558-1 (Second Edition 2005-09) and IEC/EN61558-2-4 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CE (2014 Spec Sheet) | CE compliant to IEC 61558-2-4 |
| UL (2014 Spec Sheet) | UL recognized to UL506 (XPTQ.Guide), UL file #E207860 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the 1182S15 output ratings?▾
30V C.T. @ 10A with secondaries in series, or 15V @ 20A in parallel.
What is the 1182S15 weight?▾
Shipping weight is 5.75 lbs (2.61 kg); the drawing lists 6.02 lbs +/- 4%.
Why might the 1182S15 trip a breaker when switched on?▾
Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time-delayed circuit breaker or soft-start circuitry is recommended on the supply line.
Is it UL and CSA approved?▾
The 1182 series is UL recognized to UL 5085-1 and UL 5085-2 (file #E207860) and CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (file #209651).
How do I wire the primary for 117 V or 234 V?▾
Connect the two 117 V primaries (BLK-WHT and BRN-ORN) in parallel for 117 VAC or in series for 234 VAC, 50/60 Hz. A connection sheet is included with the transformer.
Related Products
Save 52%1182S12 — Power transformer, toroid, 225 VA, with 12V @ 18.76A secondary, 1182 Series
Hammond Manufacturing · 1182S12
Save 52%1182S24 — Power transformer, toroid, 500 VA, with 24V @ 20.82A secondary, 1182 Series
Hammond Manufacturing · 1182S24
Save 52%1182S110 — Power transformer, toroid, 1000 VA, with 110V @ 9.1A secondary, 1182 Series
Hammond Manufacturing · 1182S110
Save 52%1182S30 — Power transformer, toroid, 625 VA, with 30V @ 20.84A secondary, 1182 Series
Hammond Manufacturing · 1182S30
Save 52%1182R60 — Power transformer, toroid, 1000 VA, with 60V @ 16.7A secondary, 1182 Series
Hammond Manufacturing · 1182R60