1182R60 1000 VA toroid power transformer with open center and flexible leads, 60V @ 16.7A secondary

Hammond 1182R60 1000 VA Toroid Transformer, 120V CT or 60V Output

Hammond Manufacturing|

MPN: 1182R60

|

UPC: 623980532004

In Stock
$157.54

Ships from and sold by A5 IT

Ground Shipping · $28.05Arrives by Tuesday, Oct 27
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • Two 60V windings: 120V C.T. @ 8.3A or 60V @ 16.7A
  • 2.80% voltage regulation at 1000 VA
  • #12 TEW secondary leads, #16 TEW primary leads
  • 3/8-16 x 3.50" mounting bolt with washers and nut
  • Dual 117/234 VAC, 50/60 Hz primary (parallel for 117 V, series for 234 V)
  • Class B (130 degree C) materials; 4,000 VAC RMS hi-pot primary to secondary
  • UL recognized (file #E207860) and CSA certified (file #209651)
  • Toroid core: low profile, lightweight, cool running, low stray flux (low EMI)

The 1182R60 is a 1000 VA toroid power transformer with two 60 V secondaries. Connected in series it is rated 120V C.T. @ 8.3A; in parallel it is rated 60V @ 16.7A. Engineers building 60 V or 120 V center-tapped supplies at the 1 kVA level can run it from 117 VAC or 234 VAC.

The drawing shows each secondary as 60V @ 8.30 A, with #16 TEW primary leads and #12 TEW secondary leads brought out 8"-9" and stripped 0.5" minimum. Regulation is 2.80% (dimension reference L). The open-center toroid is supplied with two 0.093" x 4.75" OD rubber washers, a 16GA x 4.30" OD steel mounting washer and a 3/8-16 bolt 3.50" long with lock washer and hex nut. Shipping weight is 16.5 lbs (7.48 kg).

On compliance, the 1182 family carries UL recognition to UL 5085-1 and UL 5085-2 under file #E207860 and CSA certification to C22.2 #66.1-6 and #66.2-6 under file #209651, and is self-declared as evaluated to applicable sections of IEC/EN61558-1 and IEC/EN61558-2-4. Windings use Class B (130 degree C) materials, primary-to-secondary insulation is hi-pot tested at 4,000 VAC RMS, and the part is listed as RoHS and REACH compliant.

The dual primary accepts 117 VAC (parallel connection) or 234 VAC (series connection) at 50/60 Hz, with a connection sheet included. Units are designed to run with every winding engaged, in series or parallel, or as an autotransformer. Plan the supply protection for toroidal inrush: the magnetizing current at energization is limited only by the primary's low DC resistance, so a slow-blow fuse, time-delayed breaker or soft-start is recommended.

Ideal For

  • 60 V or 120 V center-tapped supplies at 1000 VA
  • Equipment designed for 117 VAC or 234 VAC mains
  • Equipment for both 117 VAC and 234 VAC supplies (global use)
  • Designs needing low stray magnetic flux (low EMI) in a low-profile package

Overview

Series1182 Series - Toroid Power Transformers, 15 VA to 1500 VA
ReplacesOlder 182 Toroid Series
DescriptionPower transformer, toroid, 1000 VA, with 60V @ 16.7A secondary, 1182 Series
Part Number1182R60
Power Rating1000 VA
Product TypePower transformer, toroid
Toroid CenterOpen
Secondary TypeDual
Short DescriptionTOROID,1000VA, 50/60HZ, 60/60V
Dimension ReferenceL

Electrical

PolarityAdditive (BLK, BRN, RED and GRY)
Frequency50/60 Hz
Primary VoltageDual 117/234 VAC
Primary Connection117 VAC: parallel connection; 234 VAC: series connection
Voltage Regulation2.80%
Winding ConnectionAll windings engaged (series or parallel connected) or connected as an autotransformer
Inrush Current NoteConsider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line
Secondary (RMS) - Series120V C.T. @ 8.3A
Primary Windings (Drawing)2x 117V BLK-WHT, BRN-ORN
Secondary (RMS) - Parallel60V @ 16.7A
Secondary Windings (Drawing)2x 60V @ 8.30A RED-BLU, GRY-YEL
Hi-Pot Test, Primary - Primary600V, 60Hz, 1 sec
Secondary No-Load Voltage Test@ 117V, 60Hz: BLK & BRN to WHT & ORN; or @ 234V, 50Hz: BLK to ORN (connect BRN & WHT)
Hi-Pot Test, Primary - Secondary4000V, 60Hz, 1 sec
Hi-Pot Test, Secondary - Secondary600V, 60Hz, 1 sec
Voltage Regulation (Part Page, Rounded)3%
Hi-Pot Test, Primary - Secondary (Series Spec)4,000 VAC RMS

Identifiers

UPC623980532004
UNSPSC39121301

Leads & Wiring

Lead LengthMinimum 8" long flexible leads
Connection SheetIncluded with transformer
Primary Lead Wire#16 TEW
Secondary Lead Wire#12 TEW
Primary Lead ColoursBLK-WHT (Primary #1), BRN-ORN (Primary #2)
Secondary Lead ColoursRED-BLU (Secondary #1), GRY-YEL (Secondary #2)
Lead Length & Strip (Drawing)All leads out 8"-9" and stripped 0.5" min.

Mounting Hardware

Supplied Hardware 1Two 0.093" T x 4.75" OD rubber washers
Supplied Hardware 2One 16GA x 4.30" OD steel mounting washer
Supplied Hardware 3One 3/8-16 bolt 3.50" long with a lock washer and 3/8-16 hex nut

Packaging & Shipping

Shipping Weight16.5 lbs (7.48 kg)
Weight (Drawing)16.29 lbs +/- 4%
Country Of OriginCanada

Construction & Finish

CoreToroidal
Toroid BenefitsLow profile, lightweight, cool running / high efficiency, low stray magnetic flux leakage (low EMI)
Insulation ClassClass B (130 degree C) materials

Compliance & Certifications

ULUL recognized to UL 5085-1 and UL 5085-2, UL file #E207860
CSACSA certified to C22.2 #66.1-6 and C22.2 #66.2-6, CSA file #209651
IEC/ENSelf-declared evaluated to applicable sections of IEC/EN61558-1 (Second Edition 2005-09) and IEC/EN61558-2-4
RoHS CompliantYes
REACH CompliantYes
CE (2014 Spec Sheet)CE compliant to IEC 61558-2-4
UL (2014 Spec Sheet)UL recognized to UL506 (XPTQ.Guide), UL file #E207860

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What are the 1182R60 output ratings?▾

120V C.T. @ 8.3A in series or 60V @ 16.7A in parallel, at 1000 VA.

What regulation does the 1182R60 offer?▾

2.80% per the series table; the part page rounds it to 3%.

Why might the 1182R60 trip a breaker when switched on?▾

Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time-delayed circuit breaker or soft-start circuitry is recommended on the supply line.

Is it UL and CSA approved?▾

The 1182 series is UL recognized to UL 5085-1 and UL 5085-2 (file #E207860) and CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (file #209651).

How do I wire the primary for 117 V or 234 V?▾

Connect the two 117 V primaries (BLK-WHT and BRN-ORN) in parallel for 117 VAC or in series for 234 VAC, 50/60 Hz. A connection sheet is included with the transformer.