Hammond 1182Q12 160 VA Toroid Transformer, 24V CT or 12V Output
Ships from and sold by A5 IT
Available on backorder — ships as soon as stock arrives
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Two 12V @ 6.67A windings for 24V C.T. @ 6.67A or 12V @ 13.34A
- 7.70% voltage regulation at 160 VA
- #14 TEW secondary leads sized for parallel current
- 1/4-20 x 2.50" bolt kit with 3.75" OD rubber washers and 3.56" OD steel washer
- Dual 117/234 VAC, 50/60 Hz primary (parallel for 117 V, series for 234 V)
- Class B (130 degree C) materials; 4,000 VAC RMS hi-pot primary to secondary
- UL recognized (file #E207860) and CSA certified (file #209651)
- Toroid core: low profile, lightweight, cool running, low stray flux (low EMI)
The 1182Q12 is a 160 VA toroid transformer with two 12 V secondaries of 6.67 A each. Series connection yields 24V C.T. @ 6.67A and parallel connection yields 12V @ 13.34A, so one part covers both 12 V high-current and 24 V center-tapped designs on 117 VAC or 234 VAC mains.
Leads are #20 TEW on the primary and #14 TEW on the secondary, 8"-9" long and stripped 0.5" minimum, with secondaries coded RED-BLU and GRY-YEL. The series table lists 7.70% regulation and dimension reference F. This open-center toroid comes with two 0.062" x 3.75" OD rubber washers, one 16GA x 3.56" OD steel mounting washer and a 1/4-20 bolt 2.50" long with lock washer and hex nut. Shipping weight is 3.6 lbs (1.63 kg).
Every transformer in the 1182 series is manufactured using Class B (130 degree C) materials and hi-pot tested at 4,000 VAC RMS between primary and secondary. The series is UL recognized to UL 5085-1 and UL 5085-2 (UL file #E207860), CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (CSA file #209651), and self-declared as evaluated to applicable sections of IEC/EN61558-1 and IEC/EN61558-2-4. This part is listed as RoHS and REACH compliant.
Wiring is straightforward: the primaries go in parallel for 117 VAC operation or in series for 234 VAC, at 50 or 60 Hz, and a connection sheet ships with the unit. All windings should be engaged (series or parallel) or the unit connected as an autotransformer. Because of the toroid's magnetic properties, inrush at switch-on can sometimes blow a fuse or trip a breaker, although the overload rarely lasts longer than half a cycle; the manufacturer advises a slow-blow fuse, time-delay breaker or soft-start circuitry.
Ideal For
- 12 V high-current or 24 V center-tapped supplies
- 160 VA equipment built for dual 117/234 VAC input
- Equipment for both 117 VAC and 234 VAC supplies (global use)
- Designs needing low stray magnetic flux (low EMI) in a low-profile package
Overview
| Series | 1182 Series - Toroid Power Transformers, 15 VA to 1500 VA |
| Replaces | Older 182 Toroid Series |
| Description | Power transformer, toroid, 160 VA, with 12V @ 13.34A secondary, 1182 Series |
| Part Number | 1182Q12 |
| Power Rating | 160 VA |
| Product Type | Power transformer, toroid |
| Toroid Center | Open |
| Secondary Type | Dual |
| Short Description | TOROID, 160VA, 50/60HZ, 12/12V |
| Dimension Reference | F |
Electrical
| Polarity | Additive (BLK, BRN, RED and GRY) |
| Frequency | 50/60 Hz |
| Primary Voltage | Dual 117/234 VAC |
| Primary Connection | 117 VAC: parallel connection; 234 VAC: series connection |
| Voltage Regulation | 7.70% |
| Winding Connection | All windings engaged (series or parallel connected) or connected as an autotransformer |
| Inrush Current Note | Consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line |
| Secondary (RMS) - Series | 24V C.T. @ 6.67A |
| Primary Windings (Drawing) | 2x 117V BLK-WHT, BRN-ORN |
| Secondary (RMS) - Parallel | 12V @ 13.34A |
| Secondary Windings (Drawing) | 2x 12V @ 6.67A RED-BLU, GRY-YEL |
| Hi-Pot Test, Primary - Primary | 600V, 60Hz, 1 sec |
| Secondary No-Load Voltage Test | @ 117V, 60Hz: BLK & BRN to WHT & ORN; or @ 234V, 50Hz: BLK to ORN (connect BRN & WHT) |
| Hi-Pot Test, Primary - Secondary | 4000V, 60Hz, 1 sec |
| Hi-Pot Test, Secondary - Secondary | 600V, 60Hz, 1 sec |
| Voltage Regulation (Part Page, Rounded) | 8% |
| Hi-Pot Test, Primary - Secondary (Series Spec) | 4,000 VAC RMS |
Identifiers
| UPC | 623980531571 |
| UNSPSC | 39121301 |
Leads & Wiring
| Lead Length | Minimum 8" long flexible leads |
| Connection Sheet | Included with transformer |
| Primary Lead Wire | #20 TEW |
| Secondary Lead Wire | #14 TEW |
| Primary Lead Colours | BLK-WHT (Primary #1), BRN-ORN (Primary #2) |
| Secondary Lead Colours | RED-BLU (Secondary #1), GRY-YEL (Secondary #2) |
| Lead Length & Strip (Drawing) | All leads out 8"-9" and stripped 0.5" min. |
Mounting Hardware
| Supplied Hardware 1 | Two 0.062" T x 3.75" OD rubber washers |
| Supplied Hardware 2 | One 16GA x 3.56" OD steel mounting washer |
| Supplied Hardware 3 | One 1/4-20 bolt 2.50" long with a lock washer and 1/4-20 hex nut |
Packaging & Shipping
| Shipping Weight | 3.6 lbs (1.63 kg) |
| Weight (Drawing) | 3.75 lbs +/- 4% |
| Country Of Origin | Canada |
Construction & Finish
| Core | Toroidal |
| Toroid Benefits | Low profile, lightweight, cool running / high efficiency, low stray magnetic flux leakage (low EMI) |
| Insulation Class | Class B (130 degree C) materials |
Compliance & Certifications
| UL | UL recognized to UL 5085-1 and UL 5085-2, UL file #E207860 |
| CSA | CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6, CSA file #209651 |
| IEC/EN | Self-declared evaluated to applicable sections of IEC/EN61558-1 (Second Edition 2005-09) and IEC/EN61558-2-4 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CE (2014 Spec Sheet) | CE compliant to IEC 61558-2-4 |
| UL (2014 Spec Sheet) | UL recognized to UL506 (XPTQ.Guide), UL file #E207860 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Can the 1182Q12 supply 12 V at more than 6.67 A?▾
Yes. With the two 12 V secondaries in parallel it is rated 12V @ 13.34A.
Which bolt is supplied with the 1182Q12?▾
One 1/4-20 bolt 2.50" long with a lock washer and 1/4-20 hex nut, plus a 16GA x 3.56" OD steel mounting washer and two rubber washers.
Why might the 1182Q12 trip a breaker when switched on?▾
Toroidal transformers can draw high magnetizing current when first energized, limited only by the primary's low DC resistance; the overload rarely lasts longer than half a cycle. A slow-blow fuse, time-delayed circuit breaker or soft-start circuitry is recommended on the supply line.
Is it UL and CSA approved?▾
The 1182 series is UL recognized to UL 5085-1 and UL 5085-2 (file #E207860) and CSA certified to C22.2 #66.1-6 and C22.2 #66.2-6 (file #209651).
How do I wire the primary for 117 V or 234 V?▾
Connect the two 117 V primaries (BLK-WHT and BRN-ORN) in parallel for 117 VAC or in series for 234 VAC, 50/60 Hz. A connection sheet is included with the transformer.
Related Products
Save 52%1182Q117 — Power transformer, toroid, 750 VA, with 117V @ 6.42A secondary, 1182 Series
Hammond Manufacturing · 1182Q117

1182Q240 — Power transformer, toroid, 1500 VA, with 240V @ 6.3A secondary, 1182 Series
Hammond Manufacturing · 1182Q240
Save 52%1182Q110 — Power transformer, toroid, 625 VA, with 110V @ 5.68A secondary, 1182 Series
Hammond Manufacturing · 1182Q110
Save 52%1182Q240P — Power transformer, toroid, 1500 VA, with 240V @ 6.3A secondary, 1182 Series
Hammond Manufacturing · 1182Q240P
Save 52%1182P60 — Power transformer, toroid, 625 VA, with 60V @ 10.42A secondary, 1182 Series
Hammond Manufacturing · 1182P60