PWDP13123 Dentron Clipperton-L power transformer

Hammond PWDP13123 Dentron Clipperton-L Power Transformer, 1010 VAC

Hammond Manufacturing|

MPN: PWDP13123

|

UPC: 623980960647

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing PWDP13123.

224-955-1644
Ground Shipping · $34.99Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Power transformer for Dentron Clipperton-L (late production), modified with center-tapped filament
  • Manufacturer believes it was also used in the later Clipperton QRO
  • S1 high voltage: 0-640-1010 VAC @ 600 mA CCS
  • S3 filament: 6.3 VAC C.T. @ 16 A CCS; S2: 12 VAC @ 2 A CCS
  • Primary: 117/234 VAC, 60 Hz, single phase
  • EI-162 x 3.5 core, style 2; approx. 24 lb

The PWDP13123 is a Peter W. Dahl design power transformer for the Dentron Clipperton-L linear amplifier, late production. It is a modified version in which the filament winding includes a center tap (C.T.), and the manufacturer notes it is believed this power transformer was also used in the later Clipperton QRO. It suits amateur radio operators and technicians restoring or repairing these amplifiers.

The primary is 117/234 VAC, 60 Hz, single phase. Three secondaries are listed:

  • S1: 0-640-1010 VAC @ 600 mA CCS
  • S2: 12 VAC @ 2 A CCS
  • S3: 6.3 VAC C.T. @ 16 A CCS

The transformer is wound on an EI-162 x 3.5 core and built in style 2 of the series style sheet. Approximate weight is 24 lb, with a shipping weight of 24 lbs (10.89 kg). It is listed as REACH and RoHS compliant.

Because the PWDP13123 primary is specified for 60 Hz only, buyers outside North America should heed the series note about 50 Hz supplies. Units in this series are usually built to order one at a time, so confirm availability before ordering.

Ideal For

  • Dentron Clipperton-L amplifier repair
  • Dentron Clipperton QRO power transformer replacement
  • Vintage amateur linear amplifier restoration

Overview

SeriesPWDAHL Series (Peter W Dahl Transformers)
Part NumberPWDP13123
ModificationFilament winding includes C.T.
Series TaglineMagnetics for Amateur Radio Products
Short DescriptionDENTRON-CLIPPERON-L POWER XFMR
Ordering Table DescriptionDENTRON CLIPPERTON-L (Late Production) POWER TRANSFORMER MODIFIED (Filament winding includes C.T.) We believe this power transformer was also used in the later CLIPPERTON QRO

Dimensions

Approx. Weight24 lbs

Electrical

Primary117/234 VAC 60 HZ 1PH
Secondary S10-640-1010 VAC @ 600 MA CCS
Secondary S212 VAC @ 2A CCS
Secondary S36.3 VAC C.T. @ 16A CCS

Identifiers

UPC623980960647
UNSPSC39121301

Packaging & Shipping

Shipping Weight24 lbs (10.89 kg)

Construction & Finish

CoreEI-162 X 3.5
Style (Per Series Style Sheet)2

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

Which amplifier is the PWDP13123 for?▾

It is listed for the Dentron Clipperton-L (late production); the manufacturer believes it was also used in the later Clipperton QRO.

How does it differ from the original?▾

It is listed as modified: the filament winding includes a center tap (C.T.).

What are the secondary ratings?▾

S1 0-640-1010 VAC @ 600 mA CCS, S2 12 VAC @ 2 A CCS, and S3 6.3 VAC C.T. @ 16 A CCS.

What primary voltage does it need?▾

117/234 VAC, 60 Hz, single phase.

What does it weigh?▾

Approximately 24 lb; shipping weight is 24 lbs (10.89 kg).