Hammond PWDP13121 Henry 2KD-5 Replacement Power Transformer, 2250 VAC
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing PWDP13121.
224-955-1644Key Features
- Direct replacement for Henry 2KD-5 T1 power transformer, Henry P/N FDN-7497
- S1 high-voltage secondary: 0-1780-2250 VAC @ 400 mA CCS
- S2 secondary: 10.0 VCT @ 15 A CCS
- Primary: 115/230 VAC, 60 Hz, single phase
- EI-212 x 3 in. core, 29G M6X laminations, style 4
- Approx. weight 29 lb; REACH and RoHS compliant
The PWDP13121 is a power transformer from the Peter W. Dahl design files, listed as the T1 power transformer for the Henry 2KD-5 linear amplifier and described as a direct replacement for Henry P/N FDN-7497. It is aimed at amateur radio operators, restorers and service technicians who need a correct-spec replacement for a worn or failed original.
The single-phase primary is rated 115/230 VAC at 60 Hz. Two secondaries are provided: S1 is a tapped high-voltage winding at 0-1780-2250 VAC rated 400 mA CCS, and S2 is a 10.0 VCT winding rated 15 A CCS. The dual high-voltage taps (1780 and 2250 VAC) are part of the listed design.
Construction is on an EI-212 x 3 in. lamination stack of 29G M6X steel, built in mounting style 4 of the series style sheet. Approximate weight is 29 lb. The part is listed as REACH and RoHS compliant.
Note that the primary is listed for 60 Hz only; the series notes advise buyers outside North America to select a 50/60 Hz part if they need 50 Hz operation. PWDAHL Series transformers are usually built to order one at a time, so confirm availability by phone or e-mail before planning a restoration around the PWDP13121.
Ideal For
- Henry 2KD-5 linear amplifier restoration
- Replacement of Henry P/N FDN-7497 T1 power transformer
- Vintage amateur radio amplifier repair
Overview
| Series | PWDAHL Series (Peter W Dahl Transformers) |
| Replaces | Henry 2KD-5 T1, P/N FDN-7497 |
| Part Number | PWDP13121 |
| Series Tagline | Magnetics for Amateur Radio Products |
| Short Description | HENRY 2KD-5 POWER TRANS |
| Ordering Table Description | HENRY 2KD-5 POWER XFMR T1, P/N FDN-7497, DIRECT REPLACEMENT |
Dimensions
| Approx. Weight | 29 lbs |
Electrical
| Primary | 115/230 VAC 60 HZ 1PH |
| Secondary S1 | 0-1780-2250 VAC @ 400 MA CCS |
| Secondary S2 | 10.0 VCT @ 15A CCS |
Identifiers
| UPC | 623980999081 |
| UNSPSC | 39121301 |
Construction & Finish
| Core | EI-212 X 3" 29G M6X |
| Style (Per Series Style Sheet) | 4 |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What equipment does the PWDP13121 replace?▾
It is listed as the T1 power transformer for the Henry 2KD-5 and as a direct replacement for Henry P/N FDN-7497.
What are the secondary ratings?▾
S1 is 0-1780-2250 VAC at 400 mA CCS and S2 is 10.0 VCT at 15 A CCS.
Can it run on 50 Hz mains?▾
The primary is listed as 115/230 VAC 60 Hz single phase. The series notes advise choosing a part marked 50/60 Hz if you need 50 Hz operation.
How heavy is it?▾
The approximate weight is 29 lb.
Is this transformer kept in stock?▾
Transformers in the PWDAHL Series are usually built to order one at a time, and many of the designs are decades old, so the series notes recommend confirming availability by phone or e-mail before ordering.
Related Products

PWDP13115 — Peter Dahl
Hammond Manufacturing · PWDP13115

PWDP13123 — Dentron-Clipperon-L Power Transformer
Hammond Manufacturing · PWDP13123

PWDP13114 — Peter Dahl
Hammond Manufacturing · PWDP13114

PWDP13124 — Collins 30S-1 Peter Dahl Trans
Hammond Manufacturing · PWDP13124

PWDP13109 — Heath DX-20 Power Tx.
Hammond Manufacturing · PWDP13109