Key Features

  • 1610 VA (CCS) high voltage plate transformer
  • 3,500V C.T. R.M.S. secondary: 375ma CCS, 565ma ICAS
  • Dual 117/234 VAC, 50/60 Hz primary
  • Runs full wave bridge or full wave C.T.
  • Enclosed 4 hole chassis mount with minimum 6" leads
  • Secondary leads exit through rubber bushings (2,000 VAC and above)
  • Class A insulation (105 degrees C); Hi-Pot tested at minimum twice secondary voltage
  • CSA certified (209651); RoHS and REACH compliant

The 739A is a 700 Series high voltage (plate) transformer rated 1610 VA, with a dual 117/234 VAC, 50/60 Hz primary and a 3,500V C.T. R.M.S. high voltage secondary. It suits builders and service technicians who need a centre-tapped plate winding for a rectified high voltage supply and want the flexibility of either a 117 VAC or 234 VAC mains connection.

The high voltage secondary is rated 375ma under CCS (Continuous Commercial Service) and 565ma under ICAS (Intermittent Commercial or Amateur Service); the 1610 VA figure is a CCS rating. The unit can be run in either a full wave bridge or a full wave C.T. rectifier circuit, and the series design guide gives the voltage and current factors for each rectifier and filter arrangement.

Construction is enclosed with a 4 hole chassis mount and minimum 6" long leads. Insulation is Class A (105 degrees C), each design is Hi-Pot tested at a minimum of twice the secondary voltage, and the series is CSA certified (209651). Because the 3,500V C.T. secondary is at 2,000 VAC or above, its leads are brought out through rubber bushings. The part is listed as RoHS and REACH compliant.

Primary wiring for the 739A: for 117 VAC input, connect Blue to Black and Brown to White; for 234 VAC input, connect Brown to Black and the input is Blue and White. The same 1610 VA, 3,500V C.T. rating is also offered as the 739, which has a 115 VAC primary. Shipping weight is 34.7 lbs (15.74 kg).

Ideal For

  • High voltage plate supplies for vacuum tube equipment
  • Full wave bridge rectified high voltage DC supplies
  • Full wave centre-tapped (C.T.) rectifier supplies
  • Amateur radio (ICAS) intermittent service

Overview

Series700 Series - High Voltage (Plate) - 259 VA to 1610 VA
DescriptionTransformer, high voltage, 1610VA, 117/234 VAC to 3,500V C.T. @ 375ma., 700 series
Part Number739A
Short Description117/234V 50/60Hz 3500VCT
115 VAC Primary Equivalent739

Electrical

Frequency50/60 Hz
Hi-Pot TestMinimum of twice secondary voltage
Primary Voltage117/234 VAC
Power Rating (VA)1610 (CCS rating)
117 VAC Primary WiringConnect Blue to Black and Brown to White
234 VAC Primary WiringConnect Brown to Black; input is Blue & White
Rectifier ConfigurationsFull wave bridge or full wave C.T.
H.V. Secondary Current (CCS)375ma.
H.V. Secondary Current (ICAS)565ma.
AC High Voltage Secondary (R.M.S.)3,500V C.T.

Identifiers

UPC623980036649
UNSPSC39121301

Packaging & Shipping

Shipping Weight34.7 lbs (15.74 kg)
Weight (Series Table)34.7 lbs

Construction & Finish

Lead LengthMinimum 6" long leads
Insulation ClassClass A (105 degrees C)
Secondary Lead ExitThrough rubber bushings (at 2,000 VAC and above)
Enclosure / MountingEnclosed, 4 hole chassis mount

Compliance & Certifications

CSACertified (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What are the ratings of the 739A?▾

The 739A is rated 1610 VA (a CCS rating) with a 117/234 VAC, 50/60 Hz primary and a 3,500V C.T. R.M.S. secondary rated 375ma. CCS and 565ma. ICAS.

What do CCS and ICAS mean?▾

CCS is Continuous Commercial Service and ICAS is Intermittent Commercial or Amateur Service. The VA rating is specified as CCS.

How do I wire the 739A primary for 117 VAC or 234 VAC?▾

For 117 VAC input, connect Blue to Black and Brown to White. For 234 VAC input, connect Brown to Black; the input is then Blue and White.

What rectifier circuits can it be used with?▾

The unit can be run full wave bridge or full wave C.T.

What is the difference between the 739 and 739A?▾

Both are rated 1610 VA with a 3,500V C.T. secondary. The 739 has a 115 VAC primary; the 739A has a dual 117/234 VAC primary.

How are the high voltage leads brought out?▾

At 2,000 VAC and above the secondary leads are through rubber bushings, which applies to the 3,500V C.T. secondary of the 739A.