Hammond 739A 1610 VA 3,500V C.T. Plate Transformer, 117/234V Primary
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 1610 VA (CCS) high voltage plate transformer
- 3,500V C.T. R.M.S. secondary: 375ma CCS, 565ma ICAS
- Dual 117/234 VAC, 50/60 Hz primary
- Runs full wave bridge or full wave C.T.
- Enclosed 4 hole chassis mount with minimum 6" leads
- Secondary leads exit through rubber bushings (2,000 VAC and above)
- Class A insulation (105 degrees C); Hi-Pot tested at minimum twice secondary voltage
- CSA certified (209651); RoHS and REACH compliant
The 739A is a 700 Series high voltage (plate) transformer rated 1610 VA, with a dual 117/234 VAC, 50/60 Hz primary and a 3,500V C.T. R.M.S. high voltage secondary. It suits builders and service technicians who need a centre-tapped plate winding for a rectified high voltage supply and want the flexibility of either a 117 VAC or 234 VAC mains connection.
The high voltage secondary is rated 375ma under CCS (Continuous Commercial Service) and 565ma under ICAS (Intermittent Commercial or Amateur Service); the 1610 VA figure is a CCS rating. The unit can be run in either a full wave bridge or a full wave C.T. rectifier circuit, and the series design guide gives the voltage and current factors for each rectifier and filter arrangement.
Construction is enclosed with a 4 hole chassis mount and minimum 6" long leads. Insulation is Class A (105 degrees C), each design is Hi-Pot tested at a minimum of twice the secondary voltage, and the series is CSA certified (209651). Because the 3,500V C.T. secondary is at 2,000 VAC or above, its leads are brought out through rubber bushings. The part is listed as RoHS and REACH compliant.
Primary wiring for the 739A: for 117 VAC input, connect Blue to Black and Brown to White; for 234 VAC input, connect Brown to Black and the input is Blue and White. The same 1610 VA, 3,500V C.T. rating is also offered as the 739, which has a 115 VAC primary. Shipping weight is 34.7 lbs (15.74 kg).
Ideal For
- High voltage plate supplies for vacuum tube equipment
- Full wave bridge rectified high voltage DC supplies
- Full wave centre-tapped (C.T.) rectifier supplies
- Amateur radio (ICAS) intermittent service
Overview
| Series | 700 Series - High Voltage (Plate) - 259 VA to 1610 VA |
| Description | Transformer, high voltage, 1610VA, 117/234 VAC to 3,500V C.T. @ 375ma., 700 series |
| Part Number | 739A |
| Short Description | 117/234V 50/60Hz 3500VCT |
| 115 VAC Primary Equivalent | 739 |
Electrical
| Frequency | 50/60 Hz |
| Hi-Pot Test | Minimum of twice secondary voltage |
| Primary Voltage | 117/234 VAC |
| Power Rating (VA) | 1610 (CCS rating) |
| 117 VAC Primary Wiring | Connect Blue to Black and Brown to White |
| 234 VAC Primary Wiring | Connect Brown to Black; input is Blue & White |
| Rectifier Configurations | Full wave bridge or full wave C.T. |
| H.V. Secondary Current (CCS) | 375ma. |
| H.V. Secondary Current (ICAS) | 565ma. |
| AC High Voltage Secondary (R.M.S.) | 3,500V C.T. |
Identifiers
| UPC | 623980036649 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 34.7 lbs (15.74 kg) |
| Weight (Series Table) | 34.7 lbs |
Construction & Finish
| Lead Length | Minimum 6" long leads |
| Insulation Class | Class A (105 degrees C) |
| Secondary Lead Exit | Through rubber bushings (at 2,000 VAC and above) |
| Enclosure / Mounting | Enclosed, 4 hole chassis mount |
Compliance & Certifications
| CSA | Certified (209651) |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the ratings of the 739A?▾
The 739A is rated 1610 VA (a CCS rating) with a 117/234 VAC, 50/60 Hz primary and a 3,500V C.T. R.M.S. secondary rated 375ma. CCS and 565ma. ICAS.
What do CCS and ICAS mean?▾
CCS is Continuous Commercial Service and ICAS is Intermittent Commercial or Amateur Service. The VA rating is specified as CCS.
How do I wire the 739A primary for 117 VAC or 234 VAC?▾
For 117 VAC input, connect Blue to Black and Brown to White. For 234 VAC input, connect Brown to Black; the input is then Blue and White.
What rectifier circuits can it be used with?▾
The unit can be run full wave bridge or full wave C.T.
What is the difference between the 739 and 739A?▾
Both are rated 1610 VA with a 3,500V C.T. secondary. The 739 has a 115 VAC primary; the 739A has a dual 117/234 VAC primary.
How are the high voltage leads brought out?▾
At 2,000 VAC and above the secondary leads are through rubber bushings, which applies to the 3,500V C.T. secondary of the 739A.
Related Products
Save 52%739 — Transformer, high voltage, 1610VA, 115 VAC to 3,500V C.T. @ 375ma., 700 series
Hammond Manufacturing · 739
Save 52%742A — 117/234V 50/60Hz 5000VCT
Hammond Manufacturing · 742A
Save 52%737A — Transformer, high voltage, 1200VA, 117/234 VAC to 3,000V C.T. @ 400ma., 700 series
Hammond Manufacturing · 737A
Save 52%737 — Transformer, high voltage, 1200VA, 115 VAC to 3,000V C.T. @ 400ma., 700 series
Hammond Manufacturing · 737
Save 52%735A — Transformer, high voltage, 735VA, 117/234 VAC to 3,000V C.T. @ 250ma., 700 series
Hammond Manufacturing · 735A