Key Features

  • 329 VA rating with 1,200V C.T. @ 230mA high voltage (plate) secondary
  • Three filament windings: 5V @ 3A, 6.3V @ 3A and 6.3V @ 3A
  • 50 VAC bias tap on the high voltage secondary with C.T. grounded
  • Faraday copper primary shield and concentric windings for low stray field and low noise
  • Vertical ("X") mounting style, dimension reference X15
  • Highpot tested at 2,000 VAC; CSA certified (209651); RoHS and REACH compliant

The 384X is a 329 VA high voltage (plate) and filament power transformer from the 300 Series, aimed at builders who need a 1,200V C.T. plate supply together with three separate filament windings on one universal-primary, 50/60 Hz transformer. Its high voltage secondary is rated 1,200V C.T. at 230 mA, the highest secondary voltage in the 300 Series table, and it is a vertical ("X") mount unit with dimension reference X15.

The primary is universal: 100, 110, 120, 200, 220, 230 or 240 VAC at 50/60 Hz. The manufacturer notes that units are designed to operate with BOTH primary windings engaged, so follow the primary wiring information for the series when connecting it. A 50 VAC bias tap is taken from the high voltage secondary centre tap (C.T. grounded).

Filament windings are 5V @ 3A, 6.3V @ 3A and a second 6.3V @ 3A. The unit can be run full wave bridge or full wave C.T.

Construction follows the 300 Series design: a Faraday copper primary shield reduces capacitive coupling from the primary, attenuating higher frequency current coupling to the secondaries (the shield is internally grounded to the end bell), and the windings are concentric wound for low stray field and low noise. The finish is black powder paint to match the 1650 series of output transformers. Units are highpot tested at 2,000 VAC and the series is CSA certified (209651). The 384X is RoHS and REACH compliant and has a shipping weight of 12.5 lbs (5.67 kg).

Ideal For

  • 1,200V C.T. high voltage plate supply
  • Multiple filament supplies (5V and two 6.3V windings)
  • Full wave bridge or full wave C.T. rectified supplies
  • Equipment matched to 1650 series output transformers

Mounting

Mounting StyleVertical ("X")

Overview

Series300 Series - High Voltage (Plate) & Filament
DescriptionTransformer, high voltage & filament, 329VA, 1,200V C.T. @ 230mA, 300 Series
Short DescriptionPOWER TX

Dimensions

Dimension ReferenceX15

Electrical

WindingsConcentric wound for low stray field and low noise
Primary VACUniversal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz
Highpot Test2,000 VAC
Primary ShieldFaraday copper electrostatic shield, internally grounded to the end bell
Filament #1 VAC5V @ 3A
Filament #2 VAC6.3V @ 3A
Filament #3 VAC6.3V @ 3A
Power Rating (VA)329
Primary Wiring NoteUnits are designed to operate with BOTH primary windings engaged
Rectifier ConfigurationCan be run full wave bridge or full wave C.T.
AC High Voltage Secondary R.M.S.1,200V C.T. @ 230mA
Bias Tap On High Voltage Secondary W/ C.T. Grounded VAC50

Identifiers

UPC623980142975
UNSPSC39121301
Part Number384X

Packaging & Shipping

Shipping Weight12.5 lbs (5.67 kg)

Construction & Finish

FinishBlack powder paint (matches 1650 series output transformers)

Compliance & Certifications

CSA CertifiedYes (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the high voltage secondary rating of the 384X?▾

1,200V C.T. at 230 mA R.M.S., with a 50 VAC bias tap when the C.T. is grounded.

What filament windings does the 384X have?▾

Three: 5V @ 3A, 6.3V @ 3A and a second 6.3V @ 3A.

How is the 384X mounted?▾

It is a vertical ("X") mounting style unit, dimension reference X15.

What certifications apply?▾

The 300 Series is CSA certified (209651) and highpot tested at 2,000 VAC; the 384X is listed as RoHS and REACH compliant.