(224) 955-1644
Hammond ManufacturingAuthorized partner store
378X 237 VA 300 Series plate and filament transformer, 800V C.T. @ 230ma. secondary, black powder paint finish, vertical mounting

Hammond 378X 237VA 800V C.T. Plate & Filament Power Transformer

Hammond Manufacturing|

MPN: 378X

|

UPC: 623980278995

In Stock
$197.00

Ships from and sold by A5 IT

Ground Shipping · $22.59Arrives by Monday, Oct 26
Order within 50m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 237 VA rating with 800V C.T. @ 230ma. high voltage (plate) secondary
  • Filament windings: 5V C.T. @ 3A and 6.3V C.T. @ 6A
  • 50 VAC bias tap from the high voltage secondary with C.T. grounded
  • Faraday copper primary shield grounded to the end bell; concentric windings for low stray field and noise
  • Highpot tested at 2,000 VAC; CSA certified (209651); RoHS and REACH compliant
  • Vertical ("X") mounting, black powder paint finish, ships at 8.75 lbs (3.97 kg)

The 378X is a 237 VA high voltage (plate) and filament transformer from the 300 Series, rated 800V C.T. @ 230ma. on its A.C. high voltage secondary. It is intended for designers, builders and repair technicians working on vacuum tube equipment who need a plate supply, two filament supplies and a bias source from one universal-primary transformer.

The 378X supplies 800V C.T. at 230 mA from a 237 VA rating, with a 5V C.T. 3A filament and a 6.3V C.T. 6A filament, on the X22 dimension reference.

The universal primary accepts 100, 110, 120, 200, 220, 230 and 240 VAC at 50/60 Hz. Units are designed to operate with BOTH primary windings engaged, so follow the manufacturer's primary wiring information when connecting it. The secondary provides a 50 VAC bias tap taken from the high voltage secondary with the C.T. grounded, and the unit can be run full wave bridge or full wave C.T.

Construction includes a Faraday copper primary shield, an electrostatic shield internally grounded to the end bell that reduces capacitive coupling from the primary, and concentric windings for low stray field and low noise. Each unit is highpot tested at 2,000 VAC and finished in black powder paint to match the 1650 series of output transformers.

  • Mounting: vertical ("X") mounting
  • Shipping weight: 8.75 lbs (3.97 kg)
  • CSA certified (209651); RoHS and REACH compliant
  • UPC 623980278995

It is built on dimension reference X22 in the series specification sheet. The 300 Series is an upgrade from the entire 200 Series range of units.

Ideal For

  • High voltage (plate) supply for vacuum tube equipment
  • Filament supply at 5V C.T. and 6.3V C.T. for tube circuits
  • Bias supply from the 50 VAC tap
  • Full wave bridge or full wave C.T. rectified power supplies
  • Upgrade from Hammond 200 Series power transformers

Overview

Series300 Series - High Voltage (Plate) & Filament - 39 VA to 940 VA
DescriptionTransformer, high voltage & filament, 237VA, 800V C.T. @ 230ma., 300 Series
Part Number378X
Product TypeHigh voltage (plate) & filament transformer
Manufacturer Short DescriptionMULTI TAP PRI, 50/60HZ, 237VA

Dimensions

Dimension ReferenceX22

Electrical

PrimaryUniversal - 100, 110, 120, 200, 220,230, 240 VAC 50/60 Hz
Filament #15V C.T. @ 3A
Filament #26.3V C.T. @ 6A
Highpot Test2,000 VAC
Power Rating237 VA
Primary Wiring NoteUnits are designed to operate with BOTH primary windings engaged
Rectifier ConfigurationFull wave bridge or full wave C.T.
AC High Voltage Secondary (RMS)800V C.T. @ 230ma.
Bias Tap On High Voltage Secondary W/ C.T. Grounded50 VAC

Identifiers

UPC623980278995
UNSPSC39121301

Packaging & Shipping

Shipping Weight8.75 lbs (3.97 kg)

Construction & Finish

FinishBlack powder paint (matches 1650 series output transformers)
WindingsConcentric wound for low stray field and low noise
Mounting StyleVertical ("X")
Primary ShieldFaraday copper electrostatic shield, internally grounded to the end bell

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
CSA CertificationCSA certified (209651)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What voltages and currents does the 378X provide?▾

The 378X is rated 237 VA. Its A.C. high voltage secondary is 800V C.T. @ 230ma., and its filament windings are 5V C.T. @ 3A and 6.3V C.T. @ 6A.

Does the 378X have a bias supply?▾

Yes. It has a 50 VAC bias tap taken from the high voltage secondary with the C.T. grounded.

Can the 378X be used with a bridge rectifier?▾

Yes. Units in this series can be run full wave bridge or full wave C.T. The manufacturer's design guide gives rectifier use suggestions.

How is the 378X mounted and what does it weigh?▾

It uses vertical ("X") mounting with dimensions per reference X22 on the series specification sheet. Shipping weight is 8.75 lbs (3.97 kg).

What certifications does the 378X carry?▾

The 300 Series is CSA certified (209651), and this part is listed as RoHS and REACH compliant. Units are highpot tested at 2,000 VAC.