Hammond 2UD606212FTC 60x62x12in Type 12 Two-Door Wallmount Disconnect
Ships from and sold by A5 IT
Available on backorder — ships as soon as stock arrives
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Two-door wallmount disconnect enclosure, 60.13 x 62.00 x 12.13 in (1527 x 1575 x 308 mm)
- 56.00 x 56.00 in white powder-coated 10 gauge steel inner panel included
- UL 508A / CSA Type 12; complies with NEMA Type 12 and 13 and IEC 60529 IP54
- Universal flange cutout for multi-vendor disconnect operators via adaptor kit
- Master door interlock, screw defeater and padlock hasps on both handles
- 10 gauge steel, continuously welded, ANSI 61 gray powder coat inside and out
- Removable center post and lift-off doors for easier panel installation
The Hammond 2UD606212FTC is a Type 12 mild steel two-door wallmount disconnect enclosure with a hinged door, handle and flange with multi-vendor cutout, supplied with an inner panel. It is intended for control panel builders, OEM machine builders and plant electricians who need a wall-mounted housing for flange mounted disconnect switches and circuit breakers. It shares the 60.13 in height of the smallest 2UD model but widens the body to 62.00 in, giving a square 56.00 x 56.00 in inner panel.
Size is 60.13 in H x 62.00 in W x 12.13 in D (1527 x 1575 x 308 mm). The formed 10 gauge steel inner panel measures 56.00 x 56.00 in (1422 x 1422 mm), is finished in white powder coating and mounts on collar studs with panel supports. Each door opening is 27.85 in wide on the drawing, and the center post is removable for easy panel installation. Shipping weight is 656 lbs (297.56 kg) on a skid.
The body is formed from 10 gauge steel with smooth, continuously welded seams, phosphatized and finished in ANSI 61 gray recoatable powder coating inside and out. A flange trough collar (FTC) around the door opening excludes liquids and contaminants, oil resistant gaskets are permanently secured, and heavy duty lifting eyes are anchored into reinforced top corners. Doors hang on heavy duty lift-off hinges and close with a heavy duty three point latching mechanism with roller ends.
The right hand door is the master door, with a screw defeater and padlock hasp, and a mechanical interlock stops the auxiliary door from being opened first. The universal flange cutout accepts ABB, Allen Bradley, C-H Westinghouse / Cutler Hammer, General Electric, Siemens and Square D operators through one operator adaptor kit, ordered separately. The series is UL 508A and CSA Type 12 and complies with NEMA Type 12 and 13 and IEC 60529 IP54 when appropriate components are used.
Ideal For
- Wall-mounted housing for flange mounted disconnect switches and circuit breakers
- Machine control panels needing a door-interlocked disconnect
- Indoor industrial areas where a Type 12 / IP54 enclosure is specified
- Multi-vendor disconnect installations using operator adaptor kits
Overview
| Doors | 2 (right hand door is the master door) |
| Style | Hinge Door with Handle (Flange w/ multi-vendor cutout) |
| Series | 2UD Series - Type 12 Mild Steel Two Door Wallmount Disconnect Enclosure |
| Mounting | Wallmount |
| Part Number | 2UD606212FTC |
| Long Description | N12 Two Door Disconnect encl w/ panel - 60.13 x 62 x 12.13 - Steel/Gray |
| Material / Colour | Steel / Gray |
| Short Description | 2UDFTC - ASSEMBLY |
Dimensions
| Enclosure Depth | 12.13 in (308 mm) |
| Enclosure Width | 62.00 in (1575 mm) |
| Enclosure Height | 60.13 in (1527 mm) |
| Size (H X W X D) | 60.13 in x 62 in x 12.13 in (1,527 mm x 1,575 mm x 308 mm) |
| Inner Panel Width | 56.00 in (1422 mm) |
| Inner Panel Height | 56.00 in (1422 mm) |
| Door Opening Width (Each Door, Drawing) | 27.85 in |
Identifiers
| UPC | 623980461724 |
| UNSPSC | 39121324 |
Packaging & Shipping
| Packaging Type | Skid |
| Shipping Weight | 656 lbs (297.56 kg) |
Construction & Finish
| Hinges | Removable doors on heavy duty lift-off hinges |
| Gaskets | Oil resistant, permanently secured |
| Lifting | Heavy duty lifting eyes anchored into reinforced top corners |
| Latching | Heavy duty three point latching mechanism with heavy duty roller ends |
| Center Post | Removable, for easy panel installation |
| Inner Panel | Formed 10 gauge steel on collar studs; panel supports provided |
| Not Included | Disconnect switches, circuit breakers and operators (order separately from the manufacturer) |
| Door Interlock | Mechanical interlock activated by the master door prevents the auxiliary door from being opened first |
| Body Stiffeners | Included in the larger enclosures for extra rigidity (per series) |
| Enclosure Finish | Phosphatized, ANSI 61 gray recoatable powder coating inside and outside |
| Disconnect Cutout | Universal flange cutout; mounts disconnect operators with the appropriate operator adaptor kit |
| Literature Pocket | Inside of the door |
| Slave Door Handle | Padlock hasp |
| Enclosure Material | 10 gauge steel, smooth continuously welded seams |
| Inner Panel Finish | White powder coating |
| Lighting Provision | Provision for mounting fluorescent lighting |
| Master Door Handle | Screw defeater and padlock hasp |
| Door Opening Collar | Flange trough collar (FTC) excludes liquids and contaminants |
| Grounding / Bonding | Bonding stud in the door and grounding stud in the enclosure for each door |
Disconnect Compatibility
| Not Compatible | Square D Class 9422 bracket mounted disconnect devices, Class 9422TG1 or TG2 devices |
| Selection Guide | Refer to the Universal Disconnect Selection Guide |
| Adaptor Kit Contents | Adaptor plate and master door interlocking mechanism, with fully detailed illustrated instructions |
| Operator Adaptor Kit | One adaptor kit required (ordered separately); each brand and type requires a different kit |
| Compatible Mechanism 1 | ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers |
| Compatible Mechanism 2 | Allen Bradley 1494V and 1494U variable depth flange mounted disconnect switches and circuit breaker mechanisms |
| Compatible Mechanism 3 | C-H Westinghouse Type C361 disconnect switches and operator mechanisms; Cutler Hammer Type C371 circuit breaker operating mechanisms; Flex-Shaft handle operators for circuit breakers |
| Compatible Mechanism 4 | General Electric Type STDA flange handles and variable depth operating mechanisms; Spectra-Flex cable operators for circuit breakers |
| Compatible Mechanism 5 | Siemens I-T-E Max-Flex flange mounted variable depth operating handles |
| Compatible Mechanism 6 | Square D disconnect switches and circuit breakers used with Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms |
Environmental & Protection
| IP Rating | IEC 60529, IP54 |
| NEMA Type | 12 and 13 |
| Enclosure Type | Type 12 |
Compliance & Certifications
| UL | UL 508A Type 12 |
| CSA | CSA Type 12 |
| RoHS Compliant | Yes |
| Standards Note | Appropriate components are required to maintain these standards |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What size is the 2UD606212FTC?▾
The enclosure is 60.13 in H x 62.00 in W x 12.13 in D (1527 x 1575 x 308 mm), and the included inner panel is 56.00 x 56.00 in (1422 x 1422 mm).
Do I need an adaptor kit to mount my disconnect?▾
Yes. All universal series enclosures require one operator adaptor kit, ordered separately, to suit the type of disconnect and mechanism. Each brand and type requires a different kit, and each kit contains an adaptor plate and master door interlocking mechanism with illustrated instructions.
Which disconnect brands are supported?▾
ABB Controls, Allen Bradley 1494V/1494U, C-H Westinghouse C361/C371 and Flex Shaft, General Electric STDA and Spectra-Flex, Siemens I-T-E Max-Flex, and Square D Class 9422 flange or cable mechanisms. Square D Class 9422 bracket mounted, 9422TG1 and TG2 devices are not accepted.
Is it suitable for outdoor or wash-down use?▾
The data rates this series UL 508A and CSA Type 12 and compliant with NEMA Type 12 and 13 and IEC 60529 IP54; it does not list an outdoor or wash-down rating.
Are the disconnect switch and circuit breaker included?▾
No. Disconnect switches, circuit breakers and operators are not provided and must be ordered separately from the manufacturer.
What does the 2UD606212FTC weigh?▾
Shipping weight is 656 lbs (297.56 kg), and it ships on a skid.
Related Products
Save 33%2UD605012FTC — N12 Two Door Disconnect encl w/ panel - 60.13 x 50 x 12.13 - Steel/Gray
Hammond Manufacturing · 2UD605012FTC
Save 33%2UD726212FTC — N12 Two Door Disconnect encl w/ panel - 72.13 x 62 x 12.13 - Steel/Gray
Hammond Manufacturing · 2UD726212FTC
Save 33%2UD727412FTC — N12 Two Door Disconnect encl w/ panel - 72.13 x 74 x 12.13 - Steel/Gray
Hammond Manufacturing · 2UD727412FTC