- Two-door floormount disconnect enclosure, 60.13 x 50.00 x 12.13 in (1527 x 1270 x 308 mm)
- 56.00 x 44.00 in white powder-coated 10 gauge steel inner panel; 11.38 in usable depth
- 15 in floor stands welded to the enclosure
- UL 508A / CSA Type 12; complies with NEMA Type 12 and IEC 60529 IP54
- Universal flange cutout for multi-vendor operators via one adaptor kit
- Right hand master door with interlock, screw defeater and padlock hasp
- 10 gauge steel, continuously welded, smooth ANSI 61 gray powder coat
The Hammond 2UD605012FFTC is a Type 12 mild steel two-door floormount disconnect enclosure (hinge door with handle, flange with multi-vendor cutout) supplied with an inner panel. Control panel builders, OEM engineers and facilities electricians use it to house flange mounted disconnect switches and circuit breakers at floor level. It is the most compact model in the 2UD F series: 60.13 in tall, 50.00 in wide and 12.13 in deep.
Overall enclosure size is 60.13 in H x 50.00 in W x 12.13 in D (1527 x 1270 x 308 mm), raised on 15 in floor stands that are welded to the enclosure. The formed 10 gauge steel inner panel is 56.00 x 44.00 in (1422 x 1118 mm) in white powder coating on collar studs with panel supports, and the drawing shows 11.38 in of usable depth with a 21.85 in opening at each door. Shipping weight is 599 lbs (271.70 kg), packed on a skid.
The body is 10 gauge steel with smooth, continuously welded seams, phosphatized and finished in recoatable smooth ANSI 61 gray powder coating. A flange trough collar (FTC) around the door opening excludes liquids and contaminants and oil resistant gaskets are permanently secured. Removable doors ride on heavy duty lift-off hinges, a heavy duty three point latch with roller ends eases closing, and the center post removes for panel installation.
The right hand door is the master door, with screw defeater and padlock hasp, and it interlocks mechanically so the auxiliary door cannot be opened first. One operator adaptor kit, ordered separately, adapts the universal flange cutout to ABB, Allen Bradley, C-H Westinghouse / Cutler Hammer, General Electric, Siemens or Square D mechanisms. The series is UL 508A and CSA Type 12 (UL File E65324, CSA LR21001) and complies with NEMA Type 12 and IEC 60529 IP54 with appropriate components.
Ideal For
- Floor-standing housing for flange mounted disconnect switches and circuit breakers
- Machine control panels requiring an interlocked disconnect door
- Indoor industrial areas specifying Type 12 / IP54 protection
- Multi-vendor disconnect installations using operator adaptor kits
Overview
| Doors | 2 (right hand door is the master door) |
| Style | Hinge Door with Handle (Flange w/ multi-vendor cutout) |
| Series | 2UD F Series - Type 12 Mild Steel Two Door Floormount Disconnect Enclosure |
| Mounting | Floormount, 15 in floor stands welded to the enclosure |
| Part Number | 2UD605012FFTC |
| Long Description | N12 Two Door Disconnect encl w/ panel - 60.13 x 50 x 12.13 - Steel/Gray |
| Material / Colour | Steel / Gray |
| Short Description | 2UDFFTC - ASSEMBLY |
Dimensions
| Enclosure Depth | 12.13 in (308 mm) |
| Enclosure Width | 50.00 in (1270 mm) |
| Enclosure Height | 60.13 in (1527 mm) |
| Size (H X W X D) | 60.13 in x 50 in x 12.13 in (1,527 mm x 1,270 mm x 308 mm) |
| Inner Panel Width | 44.00 in (1118 mm) |
| Floor Stand Height | 15 in |
| Inner Panel Height | 56.00 in (1422 mm) |
| Usable Depth (Drawing) | 11.38 in |
| Door Opening Width (Each Door, Drawing) | 21.85 in |
Identifiers
| UPC | 623980461755 |
| UNSPSC | 39121324 |
Packaging & Shipping
| Packaging Type | Skid |
| Shipping Weight | 599 lbs (271.70 kg) |
Construction & Finish
| Hinges | Removable doors on heavy duty lift-off hinges |
| Gaskets | Oil resistant, permanently secured |
| Latching | Heavy duty three point latching mechanism with heavy duty roller ends |
| Center Post | Removable, for easy panel installation |
| Inner Panel | Formed 10 gauge steel on collar studs; panel supports provided |
| Floor Stands | 15 in floor stands welded to the enclosure |
| Not Included | Disconnect switches, circuit breakers and operators (order separately from the manufacturer) |
| Door Interlock | Mechanical interlock activated by the master door prevents the auxiliary door from being opened first |
| Body Stiffeners | Included in the larger enclosures for extra rigidity (per series) |
| Enclosure Finish | Phosphatized, recoatable smooth ANSI 61 gray powder coating |
| Disconnect Cutout | Universal flange cutout; mounts disconnect operators with the appropriate operator adaptor kit |
| Literature Pocket | Provided |
| Slave Door Handle | Padlock hasp |
| Enclosure Material | 10 gauge steel, smooth continuously welded seams |
| Inner Panel Finish | White powder coating |
| Lighting Provision | Provision for mounting fluorescent lighting |
| Master Door Handle | Screw defeater and padlock hasp |
| Door Opening Collar | Flange trough collar (FTC) excludes liquids and contaminants |
| Grounding / Bonding | Bonding stud in the door and grounding stud in the enclosure for each door |
Disconnect Compatibility
| Not Compatible | Square D Class 9422 bracket mounted disconnect devices, Class 9422TG1 or TG2 devices |
| Selection Guide | Refer to the Universal Disconnect Selection Guide |
| Adaptor Kit Contents | Adaptor plate and master door interlocking mechanism, with fully detailed illustrated instructions |
| Operator Adaptor Kit | One adaptor kit required (ordered separately); each brand and type requires a different kit |
| Compatible Mechanism 1 | ABB Controls flange mounted variable depth operating mechanisms for disconnect switches and circuit breakers |
| Compatible Mechanism 2 | Allen Bradley 1494V and 1494U variable depth flange mounted disconnect switches and circuit breaker mechanisms |
| Compatible Mechanism 3 | C-H Westinghouse Type C361 disconnect switches and operator mechanisms; Cutler Hammer Type C371 circuit breaker operating mechanisms; Flex-Shaft handle operators for circuit breakers |
| Compatible Mechanism 4 | General Electric Type STDA flange handles and variable depth operating mechanisms; Spectra-Flex cable operators for circuit breakers |
| Compatible Mechanism 5 | Siemens I-T-E Max-Flex flange mounted variable depth operating handles |
| Compatible Mechanism 6 | Square D disconnect switches and circuit breakers used with Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms |
Environmental & Protection
| IP Rating | IEC 60529, IP54 |
| NEMA Type | 12 |
| Enclosure Type | Type 12 |
Compliance & Certifications
| UL | UL 508A Type 12 |
| CSA | CSA Type 12 |
| UL File # | E65324 |
| CSA Cert. # | LR21001 |
| RoHS Compliant | Yes |
| Standards Note | Appropriate components are required to maintain these standards |
| REACH Compliant | Yes |
| Additional Declarations | RoHS Directive 2011/65/EU; Directive (EU) 2015/863 |
| EU Declaration Of Conformity | Low Voltage Directive 2014/35/EU (Disconnect Enclosures product series) |
| Applicable Standard IP Code) | EN 60529: 1992 + A2: 2013 / IEC 60529: 2001-02 + A2: 2013-08 |
| Applicable Standard (Machinery) | EN 60204-1: 2006 / IEC 60204-1: 2005-10, Safety of Machinery - Electrical Equipment of Machines - Part 1: General Requirements |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
How big is the 2UD605012FFTC?▾
The enclosure is 60.13 in H x 50.00 in W x 12.13 in D (1527 x 1270 x 308 mm). Its inner panel is 56.00 x 44.00 in (1422 x 1118 mm), and the drawing shows 11.38 in of usable depth.
Is an operator adaptor kit required?▾
Yes. One adaptor kit, ordered separately, is required to adapt the universal flange cutout to the disconnect and mechanism used. Each brand and type needs a different kit; each kit holds an adaptor plate and master door interlocking mechanism with illustrated instructions.
Does it stand on the floor by itself?▾
Yes. It has 15 in floor stands welded to the enclosure.
What disconnect mechanisms does it accept?▾
ABB Controls, Allen Bradley 1494V/1494U, C-H Westinghouse C361/C371 and Flex Shaft, General Electric STDA and Spectra-Flex, Siemens I-T-E Max-Flex and Square D Class 9422 flange or cable mechanisms. It will not receive Square D Class 9422 bracket mounted, 9422TG1 or TG2 devices.
Are disconnect switches or breakers supplied?▾
No. Disconnect switches, circuit breakers and operators are not provided and must be ordered separately from the manufacturer.
What is the shipping weight?▾
599 lbs (271.70 kg), shipped on a skid.
Related Products
Save 33%2UD605018FFTC — N12 Two Door Disconnect encl w/ panel - 60.13 x 50 x 18.13 - Steel/Gray
Hammond Manufacturing · 2UD605018FFTC
Save 33%2UD606212FFTC — N12 Two Door Disconnect encl w/ panel - 60.13 x 62 x 12.13 - Steel/Gray
Hammond Manufacturing · 2UD606212FFTC
Save 33%2UD606218FFTC — N12 Two Door Disconnect encl w/ panel - 60.13 x 62 x 18.13 - Steel/Gray
Hammond Manufacturing · 2UD606218FFTC
Save 33%2UD726212FFTC — N12 Two Door Disconnect encl w/ panel - 72.13 x 62 x 12.13 - Steel/Gray
Hammond Manufacturing · 2UD726212FFTC
Save 33%2UD726218FFTC — N12 Two Door Disconnect encl w/ panel - 72.13 x 62 x 18.13 - Steel/Gray
Hammond Manufacturing · 2UD726218FFTC