(224) 955-1644
Hammond ManufacturingAuthorized partner store
273DX 101 VA high voltage plate and filament transformer, vertical (X) enclosed chassis mount, 700V C.T. @ 103mA secondary

Hammond 273DX 101 VA 50/60 Hz Plate Transformer, 700V C.T. Vertical

Hammond Manufacturing|

MPN: 273DX

|

UPC: 623980241821

In Stock
$108.43

Ships from and sold by A5 IT

Ground Shipping · $21.08Arrives by Monday, Oct 26
Order within 51m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 101 VA rating; 700V C.T. @ 103mA RMS high voltage (plate) secondary
  • 117 VAC primary, 50/60 Hz
  • Filament windings: 5V @ 2A and 6.3V C.T. @ 3A
  • Enclosed, 4 hole, chassis mount in the vertical (X) style, 2.88 in (73 mm) x 3.50 in (89 mm)
  • Runs full wave bridge or full wave C.T.
  • Class A insulation (105 degrees C), 2,000V RMS hi-pot test, minimum 6 in leads
  • CSA certified (209651); RoHS and REACH compliant
  • Shipping weight 4.6 lbs (2.09 kg)

The 273DX is a 101 VA high voltage (plate) and filament transformer with a 117 VAC primary rated for 50/60 Hz. It supplies a 700V center-tapped high voltage secondary (350-0-350) at 103 mA, a 5V @ 2A winding and a center-tapped 6.3V filament winding at 3A, in the vertical (X) mounting style.

Electrically, the 273DX is rated 101 VA with a 117 VAC, 50/60 Hz primary, a high voltage secondary rated 700V C.T. @ 103mA (RMS), and filament windings of 5V @ 2A (#1) and 6.3V C.T. @ 3A (#2). As with every 200 Series unit, it can be run full wave bridge or full wave C.T. The 273DZ carries the same winding ratings in a horizontal (Z) mount; the 273DX case is 2.88 in by 3.50 in, a size listed for no other part in this group.

The case is an enclosed, 4 hole, chassis mount design in the vertical (X) mounting style, with minimum 6 in long leads. Listed dimensions are A 2.88 in (73 mm), B 3.50 in (89 mm), C 3.50 in (89 mm), D 2.25 in (57 mm), F 2.44 in (62 mm), with 0.20 in (5 mm) x 0.38 in (10 mm) mounting slots. Shipping weight is 4.6 lbs (2.09 kg).

Its primary is listed at 117 VAC, 50/60 Hz, so it is one of the 200 Series parts suited to both 50 Hz and 60 Hz supplies. Insulation is Class A (105 degrees C), units are hi-pot tested at 2,000V RMS, the design is CSA certified (209651), and the part is RoHS and REACH compliant.

Ideal For

  • High voltage (plate) supply using a full wave bridge rectifier
  • Full wave center-tapped (C.T.) rectifier plate supply
  • 5V filament supply plus 6.3V C.T. filament supply
  • Chassis-mounted power supplies on 117 VAC, 50/60 Hz lines

Mounting

LeadsMinimum 6" long leads
Mounting TypeVertical ("X")
Mounting StyleEnclosed, 4 hole, chassis mount

Overview

Series200 Series - High Voltage (Plate) & Filament - 32 VA to 454 VA
DescriptionTransformer, high voltage, 101VA, primary 117VAC, HV secondary 700V C.T. @ 103ma.
Part Number273DX
Product TypeHigh voltage (plate) and filament power transformer
Short Description350-0-350, 5V@2A, 6.3VCT@3A

Dimensions

Dimension A2.88 in (73 mm)
Dimension B3.50 in (89 mm)
Dimension C3.50 in (89 mm)
Dimension D2.25 in (57 mm)
Dimension F2.44 in (62 mm)
Mounting Slot (G)0.20 in (5 mm) x 0.38 in (10 mm)

Electrical

Filament #15V @ 2A
Filament #26.3V C.T. @ 3A
Power Rating101 VA
Primary Voltage117 VAC
Primary Frequency50/60 Hz
Primary Winding NoteProduction "running change" made to the primary winding, effective with August 2009 production
Rectifier ConfigurationFull wave bridge or full wave C.T.
AC High Voltage Secondary (RMS)700V C.T. @ 103ma.

Identifiers

UPC623980241821
UNSPSC39121301

Packaging & Shipping

Shipping Weight4.6 lbs (2.09 kg)

Construction & Finish

EnclosureEnclosed
InsulationClass A insulation (105 degrees C)

Compliance & Certifications

Hi-Pot Test2,000V RMS
RoHS CompliantYes
REACH CompliantYes
CSA CertificationCSA certified (209651)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What voltages does the 273DX provide?▾

The 273DX provides a high voltage secondary rated 700V C.T. @ 103mA (RMS) plus filament windings of 5V @ 2A (#1) and 6.3V C.T. @ 3A (#2), from a 117 VAC, 50/60 Hz primary, with a 101 VA rating.

Can the 273DX be used with a full wave bridge rectifier?▾

Yes. 200 Series units can be run full wave bridge or full wave C.T. (center-tapped).

Will the 273DX work on 50 Hz power?▾

Yes. The 273DX primary is listed at 117 VAC, 50/60 Hz.

What certifications and insulation does the 273DX have?▾

The 200 Series design is CSA certified (209651), uses Class A insulation (105 degrees C) and is hi-pot tested at 2,000V RMS. The part is RoHS and REACH compliant.

How is the 273DX mounted and how much does it weigh?▾

It is an enclosed, 4 hole, chassis mount transformer in the vertical (X) mounting style, with dimension A 2.88 in (73 mm) and B 3.50 in (89 mm). Shipping weight is 4.6 lbs (2.09 kg).