Create Free Business AccountKey Features
- 159 VA rating; 650V C.T. @ 172mA RMS high voltage (plate) secondary
- 117 VAC primary, 50/60 Hz
- Filament windings: 5V @ 3A and 6.3V C.T. @ 5A
- Enclosed, 4 hole, chassis mount in the horizontal (Z) style
- Runs full wave bridge or full wave C.T.
- Class A insulation (105 degrees C), 2,000V RMS hi-pot test, minimum 6 in leads
- CSA certified (209651); RoHS and REACH compliant
- Shipping weight 5.9 lbs (2.68 kg)
The 273CZ is a 159 VA high voltage (plate) and filament transformer in the horizontal (Z) mounting style, with a 117 VAC primary rated for 50/60 Hz. It provides a 650V center-tapped secondary (325-0-325) at 172 mA, a 5V @ 3A winding and a center-tapped 6.3V filament winding at 5A.
Electrically, the 273CZ is rated 159 VA with a 117 VAC, 50/60 Hz primary, a high voltage secondary rated 650V C.T. @ 172mA (RMS), and filament windings of 5V @ 3A (#1) and 6.3V C.T. @ 5A (#2). As with every 200 Series unit, it can be run full wave bridge or full wave C.T. It is the higher-power 650V C.T. horizontal option; the 273AZ offers the same 650V C.T. rating at 49 VA and 46 mA.
The case is an enclosed, 4 hole, chassis mount design in the horizontal (Z) mounting style, with minimum 6 in long leads. Listed dimensions are A 2.50 in (64 mm), B 3.13 in (80 mm), C 3.81 in (97 mm), D 2.00 in (51 mm), F 2.69 in (68 mm), G 1.33 in (34 mm), H 3.75 in (95 mm), J 3.13 in (80 mm). Shipping weight is 5.9 lbs (2.68 kg).
The 273CZ is a Z-mount part, and the series notes state that most Z mounts do not use the 115V/125V primary choices offered on other 200 Series units, so check the part drawing for its available primary voltages; the listed primary is 117 VAC at 50/60 Hz. Insulation is Class A (105 degrees C), units are hi-pot tested at 2,000V RMS, the design is CSA certified (209651), and the part is RoHS and REACH compliant.
Ideal For
- High voltage (plate) supply using a full wave bridge rectifier
- Full wave center-tapped (C.T.) rectifier plate supply
- 5V filament supply plus 6.3V C.T. filament supply
- Chassis-mounted power supplies on 117 VAC, 50/60 Hz lines
- Chassis layouts needing a horizontal (Z) mount transformer
Mounting
| Leads | Minimum 6" long leads |
| Mounting Type | Horizontal ("Z") |
| Mounting Style | Enclosed, 4 hole, chassis mount |
Overview
| Series | 200 Series - High Voltage (Plate) & Filament - 32 VA to 454 VA |
| Description | Transformer, high voltage, 159VA, primary 117VAC, HV secondary 650V C.T. @ 172ma. |
| Part Number | 273CZ |
| Product Type | High voltage (plate) and filament power transformer |
| Short Description | 325-0-325,5V@3A, 6.3VCT@5A |
Dimensions
| Dimension A | 2.50 in (64 mm) |
| Dimension B | 3.13 in (80 mm) |
| Dimension C | 3.81 in (97 mm) |
| Dimension D | 2.00 in (51 mm) |
| Dimension F | 2.69 in (68 mm) |
| Dimension G | 1.33 in (34 mm) |
| Dimension H | 3.75 in (95 mm) |
| Dimension J | 3.13 in (80 mm) |
Electrical
| Filament #1 | 5V @ 3A |
| Filament #2 | 6.3V C.T. @ 5A |
| Power Rating | 159 VA |
| Primary Voltage | 117 VAC |
| Primary Frequency | 50/60 Hz |
| Primary Voltage Note | Most "Z" mounts do not apply to the 115V/125V primary choices; see the part drawing for available primary voltages |
| Primary Winding Note | Production "running change" made to the primary winding, effective with August 2009 production |
| Rectifier Configuration | Full wave bridge or full wave C.T. |
| AC High Voltage Secondary (RMS) | 650V C.T. @ 172ma. |
Identifiers
| UPC | 623980241807 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 5.9 lbs (2.68 kg) |
Construction & Finish
| Enclosure | Enclosed |
| Insulation | Class A insulation (105 degrees C) |
Compliance & Certifications
| Hi-Pot Test | 2,000V RMS |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CSA Certification | CSA certified (209651) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What voltages does the 273CZ provide?▾
The 273CZ provides a high voltage secondary rated 650V C.T. @ 172mA (RMS) plus filament windings of 5V @ 3A (#1) and 6.3V C.T. @ 5A (#2), from a 117 VAC, 50/60 Hz primary, with a 159 VA rating.
Can the 273CZ be used with a full wave bridge rectifier?▾
Yes. 200 Series units can be run full wave bridge or full wave C.T. (center-tapped).
Does the 273CZ have the 115V/125V primary choice?▾
The series notes say most Z mounts do not apply to the 115V/125V primary choices and to check each part's drawing for available primary voltages. The 273CZ primary is listed at 117 VAC, 50/60 Hz.
Will the 273CZ work on 50 Hz power?▾
Yes. The 273CZ primary is listed at 117 VAC, 50/60 Hz.
What certifications and insulation does the 273CZ have?▾
The 200 Series design is CSA certified (209651), uses Class A insulation (105 degrees C) and is hi-pot tested at 2,000V RMS. The part is RoHS and REACH compliant.
How is the 273CZ mounted and how much does it weigh?▾
It is an enclosed, 4 hole, chassis mount transformer in the horizontal (Z) mounting style, with dimension A 2.50 in (64 mm) and B 3.13 in (80 mm). Shipping weight is 5.9 lbs (2.68 kg).
Related Products
Save 52%273BX — Transformer, high voltage, 182VA, primary 115VAC, HV secondary 700V C.T. @ 201ma.
Hammond Manufacturing · 273BX
Save 52%273DX — Transformer, high voltage, 101VA, primary 117VAC, HV secondary 700V C.T. @ 103ma.
Hammond Manufacturing · 273DX
Save 52%273AZ — Transformer, high voltage, 49VA, primary 117VAC, HV secondary 650V C.T. @ 46ma.
Hammond Manufacturing · 273AZ
Save 52%273DZ — Transformer, high voltage, 101VA, primary 117VAC, HV secondary 700V C.T. @ 103ma.
Hammond Manufacturing · 273DZ
Save 52%272X — Transformer, high voltage, 74VA, primary 115VAC, HV secondary 620V C.T. @ 80ma.
Hammond Manufacturing · 272X