Hammond 270CAX 65 VA 50/60 Hz Plate Transformer, 500V C.T. 81mA
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 65 VA rating; 500V C.T. @ 81mA RMS high voltage (plate) secondary
- 117 VAC primary, 50/60 Hz
- Filament windings: 5V @ 2A and 6.3V @ 2.5A
- Enclosed, 4 hole, chassis mount in the vertical (X) style, 2.50 in (64 mm) x 3.00 in (76 mm)
- Runs full wave bridge or full wave C.T.
- Class A insulation (105 degrees C), 2,000V RMS hi-pot test, minimum 6 in leads
- CSA certified (209651); RoHS and REACH compliant
- Shipping weight 3.2 lbs (1.45 kg)
The 270CAX is a 65 VA high voltage (plate) and filament transformer with a 117 VAC primary rated for 50/60 Hz, one of the few 200 Series parts listed for both line frequencies. Its 500V center-tapped secondary is rated at 81 mA (listed in the short description as 250-0-250), and it adds a 5V @ 2A winding and a 6.3V @ 2.5A filament winding.
Electrically, the 270CAX is rated 65 VA with a 117 VAC, 50/60 Hz primary, a high voltage secondary rated 500V C.T. @ 81mA (RMS), and filament windings of 5V @ 2A (#1) and 6.3V @ 2.5A (#2). As with every 200 Series unit, it can be run full wave bridge or full wave C.T. The manufacturer's short description identifies the 6.3V winding as center-tapped (6.3VCT@2.5A).
The case is an enclosed, 4 hole, chassis mount design in the vertical (X) mounting style, with minimum 6 in long leads. Listed dimensions are A 2.50 in (64 mm), B 3.00 in (76 mm), C 3.13 in (80 mm), D 2.00 in (51 mm), F 2.06 in (52 mm), with 0.20 in (5 mm) x 0.38 in (10 mm) mounting slots. Shipping weight is 3.2 lbs (1.45 kg).
Its primary is listed at 117 VAC, 50/60 Hz, so it is one of the 200 Series parts suited to both 50 Hz and 60 Hz supplies. Insulation is Class A (105 degrees C), units are hi-pot tested at 2,000V RMS, the design is CSA certified (209651), and the part is RoHS and REACH compliant.
Ideal For
- High voltage (plate) supply using a full wave bridge rectifier
- Full wave center-tapped (C.T.) rectifier plate supply
- 5V filament supply plus 6.3V filament supply
- Chassis-mounted power supplies on 117 VAC, 50/60 Hz lines
Mounting
| Leads | Minimum 6" long leads |
| Mounting Type | Vertical ("X") |
| Mounting Style | Enclosed, 4 hole, chassis mount |
Overview
| Series | 200 Series - High Voltage (Plate) & Filament - 32 VA to 454 VA |
| Description | Transformer, high voltage, 65VA, primary 117VAC, HV secondary 500V C.T. @ 81ma. |
| Part Number | 270CAX |
| Product Type | High voltage (plate) and filament power transformer |
| Short Description | 250-0-250,5V@2A, 6.3VCT@2.5A |
Dimensions
| Dimension A | 2.50 in (64 mm) |
| Dimension B | 3.00 in (76 mm) |
| Dimension C | 3.13 in (80 mm) |
| Dimension D | 2.00 in (51 mm) |
| Dimension F | 2.06 in (52 mm) |
| Mounting Slot (G) | 0.20 in (5 mm) x 0.38 in (10 mm) |
Electrical
| Filament #1 | 5V @ 2A |
| Filament #2 | 6.3V @ 2.5A |
| Power Rating | 65 VA |
| Primary Voltage | 117 VAC |
| Primary Frequency | 50/60 Hz |
| Primary Winding Note | Production "running change" made to the primary winding, effective with August 2009 production |
| Rectifier Configuration | Full wave bridge or full wave C.T. |
| AC High Voltage Secondary (RMS) | 500V C.T. @ 81ma. |
Identifiers
| UPC | 623980241760 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 3.2 lbs (1.45 kg) |
Construction & Finish
| Enclosure | Enclosed |
| Insulation | Class A insulation (105 degrees C) |
Compliance & Certifications
| Hi-Pot Test | 2,000V RMS |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| CSA Certification | CSA certified (209651) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What voltages does the 270CAX provide?▾
The 270CAX provides a high voltage secondary rated 500V C.T. @ 81mA (RMS) plus filament windings of 5V @ 2A (#1) and 6.3V @ 2.5A (#2), from a 117 VAC, 50/60 Hz primary, with a 65 VA rating.
Can the 270CAX be used with a full wave bridge rectifier?▾
Yes. 200 Series units can be run full wave bridge or full wave C.T. (center-tapped).
Will the 270CAX work on 50 Hz power?▾
Yes. The 270CAX primary is listed at 117 VAC, 50/60 Hz.
What certifications and insulation does the 270CAX have?▾
The 200 Series design is CSA certified (209651), uses Class A insulation (105 degrees C) and is hi-pot tested at 2,000V RMS. The part is RoHS and REACH compliant.
How is the 270CAX mounted and how much does it weigh?▾
It is an enclosed, 4 hole, chassis mount transformer in the vertical (X) mounting style, with dimension A 2.50 in (64 mm) and B 3.00 in (76 mm). Shipping weight is 3.2 lbs (1.45 kg).
Related Products
Save 52%270BX — Transformer, high voltage, 53VA, primary 115VAC, HV secondary 550V C.T. @ 57.5ma.
Hammond Manufacturing · 270BX
Save 52%270CX — Transformer, high voltage, 59VA, primary 115VAC, HV secondary 550V C.T. @ 75ma.
Hammond Manufacturing · 270CX
Save 52%270AX — Transformer, high voltage, 42VA, primary 115VAC, HV secondary 480V C.T. @ 58ma.
Hammond Manufacturing · 270AX
Save 52%270DAX — Transformer, high voltage, 76VA, primary 117VAC, HV secondary 520V C.T. @ 104ma.
Hammond Manufacturing · 270DAX
Save 52%269JX — Transformer, high voltage, 50VA, primary 115VAC, HV secondary 500V C.T. @ 69ma.
Hammond Manufacturing · 269JX