(224) 955-1644
Hammond ManufacturingAuthorized partner store
266JA12 open-style chassis-mount power transformer, 12 VA, with dual bobbin and colour-coded leads

Hammond 266JA12 12VA Transformer, 12V C.T. or 6V Parallel, Style V

Hammond Manufacturing|

MPN: 266JA12

|

UPC: 623980024851

In Stock
$14.44

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Tuesday, Oct 27
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 12 VA rating: 12V @ 1A series (C.T.) or 6V @ 2A parallel
  • Dual primary for 117 VAC (parallel) or 234 VAC (series), 50/60 Hz
  • Dual secondaries: center-tapped, parallel connected or used individually
  • Class B (130 °C) insulation; UL listed as a Class A (105 °C) design
  • Dual bobbin design - no electrostatic shield required; hi-pot tested at 2,000V RMS
  • Open-style chassis mount, mounting style V, minimum 6" leads
  • UL listed (# E207860) Type 3AH, CSA certified (209651), RoHS and REACH compliant

The 266JA12 is a compact 12 VA power transformer with mounting style V, rated 12 V center tapped at 1 A or 6 V at 2 A in parallel, for small chassis-mounted low-voltage circuits fed from 117 V or 234 V. It belongs to the Hammond 266 Series of low voltage/filament transformers and is aimed at OEM engineers, repair technicians and panel builders who mount the transformer directly to a chassis.

The primary is a dual 117/234 VAC, 50/60 Hz winding: connect the two primary halves in parallel for 117 V or in series for 234 V. The dual secondaries can be used as a center-tapped secondary (12V @ 1A), connected in parallel (6V @ 2A) or used individually, and the unit is designed for use with all windings engaged.

Construction is open style with a dual bobbin design, so no electrostatic shield is required. Hammond uses Class B (130 °C) insulation for extra protection, while the design is UL listed as Class A (105 °C). Every unit is hi-pot tested at 2,000V RMS, and all leads are a minimum of 6 in long. The transformer is UL listed (# E207860) Type 3AH, CSA certified (209651), and RoHS and REACH compliant.

The 266JA12 uses mounting style V with 0.19 in (5 mm) mounting holes. Its listed dimensions are A 2.88 in (73 mm), B 1.73 in (44 mm), C 2.37 in (60 mm) and D 2.38 in (60 mm). It weighs 1 lbs (0.45 kg) and ships at 1 lbs (0.45 kg).

Ideal For

  • 6 V or 12 V centre-tapped low-voltage supply
  • Chassis-mount low voltage/filament power supply
  • Equipment built for either 117 VAC or 234 VAC, 50/60 Hz mains
  • Center-tapped, parallel or dual independent secondary outputs

Mounting

Mounting StyleV
Mounting Hole Width0.19 in (5 mm)
Mounting Hole Size, Width-wise (Drawing)0.187 in / 5 mm

Overview

Series266 Series
Product TypePower transformer, low voltage/filament, dual primary & secondary
Long DescriptionPower transformer, chassis mount, 12VA, 12V @ 1A or 6V @ 2A, 266 Series
Short DescriptionPOWER TX 24V@0.5A, 12V @1A
Construction StyleOpen style, chassis mount

Dimensions

Dimension A2.88 in (73 mm)
Dimension B1.73 in (44 mm)
Dimension C2.37 in (60 mm)
Dimension D2.38 in (60 mm)

Electrical

Primary117/234 VAC, 50/60 Hz (dual primary)
Hi-Pot Test2,000V RMS
Winding UseDesigned for use with all windings engaged
Power Rating (VA)12
Secondary ConfigurationDual secondaries; usable as a center-tapped secondary, parallel connected or individually
Primary Wiring For 117 VParallel connection of primaries
Primary Wiring For 234 VSeries connection of primaries
Secondary VAC (RMS), Parallel6V @ 2A
Secondary VAC (RMS), Series (C.T.)12V @ 1A

Identifiers

UPC623980024851
UNSPSC39121301
Part Number266JA12

Packaging & Shipping

Unit Weight1 lbs (0.45 kg)
Shipping Weight1 lbs (0.45 kg)

Construction & Finish

LeadsMinimum 6" (6.00 in) long leads
BobbinDual bobbin design - no electrostatic shield required
InsulationClass B (130 °C); UL listed as a Class A (105 °C) design

Compliance & Certifications

ULUL listed (# E207860) Type 3AH
CSACSA certified (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the output of the 266JA12?▾

The series ordering table and part page list 12V @ 1A series (C.T.) and 6V @ 2A parallel, for a 12 VA rating. Note that the manufacturer's short description reads "POWER TX 24V@0.5A, 12V @1A"; the long description and ordering table give 12V @ 1A or 6V @ 2A.

Can the 266JA12 run on 234 V as well as 117 V?▾

Yes. The primary is rated 117/234 VAC, 50/60 Hz. Wire the two primary windings in parallel for 117 V or in series for 234 V.

What are the dimensions and weight of the 266JA12?▾

Mounting style V; dimensions A 2.88 in (73 mm), B 1.73 in (44 mm), C 2.37 in (60 mm), D 2.38 in (60 mm). Unit weight is 1 lbs (0.45 kg); shipping weight is 1 lbs (0.45 kg).

What certifications does the 266JA12 carry?▾

The 266 Series is UL listed (# E207860) Type 3AH and CSA certified (209651). This part is listed as RoHS compliant and REACH compliant.

Does it need an electrostatic shield?▾

No. The dual bobbin design means no electrostatic shield is required.