Hammond 266J6 6.3VA 6.3V/3.15V 1A Filament Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 6.3 VA: 6.3V @ 1A series (C.T.) or 3.15V @ 2A parallel
- 117/234 VAC, 50/60 Hz dual primary (parallel for 117 V, series for 234 V)
- Secondaries usable center tapped, parallel connected or individually
- Mounting style A; A 2.82 in (72 mm) x B 1.60 in (41 mm) x C 1.69 in (43 mm)
- Open style with minimum 6" long leads
- Dual bobbin design - no electrostatic shield required
- Class B (130 °C) insulation, UL listed as Class A (105 °C); hi-pot tested at 2,000V RMS
- UL listed (# E207860) Type 3AH, CSA certified (209651), RoHS and REACH compliant
The 266J6 is a 6.3 VA filament and low-voltage transformer rated 6.3 V at 1 A in series (center-tapped) or 3.15 V at 2 A in parallel. It is a straightforward 6.3 V, 1 A filament winding for equipment fed from 117 or 234 VAC.
The primary accepts 117 or 234 VAC at 50/60 Hz; the 266 Series connection diagrams show the primaries wired in parallel for 117 VAC and in series for 234 VAC. The secondaries can be used as a center tapped secondary (6.3V @ 1A), parallel connected (3.15V @ 2A) or used individually, and the unit is designed for use with all windings engaged. Every unit is hi-pot tested at 2,000V RMS.
Construction is open style with minimum 6" long leads and a dual bobbin design, so no electrostatic shield is required. Class B insulation (130 °C) is used for extra protection, and the design is UL listed as a Class A (105 °C) design.
It provides a full 1 A at 6.3 V, above the 0.6 A 266GB6 and below the 1.2 A 266JB6. The ordering table gives mounting style A, dimensions A 2.82 in (72 mm), B 1.60 in (41 mm), C 1.69 in (43 mm) and D 2.38 in (60 mm), a mounting hole width of 0.19 in (5 mm) and a weight of 0.7 lb (0.32 kg); shipping weight is 0.7 lbs (0.32 kg).
The series is UL listed (# E207860) Type 3AH and CSA certified (209651), and the 266J6 is listed as RoHS and REACH compliant (UPC 623980024844).
Ideal For
- 6.3 V filament supply at 1 A
- 3.15 VAC parallel-connected supply at 2 A
- Chassis-mounted equipment for 117 VAC or 234 VAC mains
Overview
| Type | Open style, chassis mount |
| Series | 266 Series |
| Description | Power transformer, chassis mount, 6.3VA, 6.3V @ 1A or 3.15V @ 2A, 266 Series |
| Part Number | 266J6 |
| Series Name | Low Voltage/Filament, Dual Primary & Secondary |
| Manufacturer Short Description | POWER TX 6.3@1A |
Dimensions
| Weight | 0.7 lbs (0.32 kg) |
| Dimension A | 2.82 in (72 mm) |
| Dimension B | 1.60 in (41 mm) |
| Dimension C | 1.69 in (43 mm) |
| Dimension D | 2.38 in (60 mm) |
| Mounting Style | A |
| Mounting Hole Width | 0.19 in (5 mm) (drawing: 0.187 in / 5 mm) |
Electrical
| Primary | 117/234 VAC, 50/60 Hz (dual primary) |
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 6.3 VA |
| Winding Note | Designed for use with all windings engaged |
| Secondary Use | Center tapped secondary, parallel connected or used individually |
| Primary Wiring | Parallel connection for 117 VAC; series connection for 234 VAC |
| Secondary (RMS), Parallel | 3.15V @ 2A |
| Secondary (RMS), Series (C.T.) | 6.3V @ 1A |
| Lead Colours (Connection Diagram) | Primary: Blk, Wht, Brn, Orn; Secondary: Red, Blu, Gry, Yel |
Identifiers
| UPC | 623980024844 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 0.7 lbs (0.32 kg) |
Construction & Finish
| Leads | Minimum 6" long leads |
| Style | Open style |
| Insulation | Class B (130 °C) insulation; UL listed as a Class A (105 °C) design |
| Bobbin Design | Dual bobbin - no electrostatic shield required |
Compliance & Certifications
| UL | UL listed (# E207860) Type 3AH |
| CSA | CSA certified (209651) |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output voltages does the 266J6 provide?▾
With the secondaries in series (center tapped) the 266J6 gives 6.3V @ 1A; with them in parallel it gives 3.15V @ 2A. It is rated 6.3 VA.
Can the 266J6 run on 234 VAC as well as 117 VAC?▾
Yes. The primary is 117/234 VAC, 50/60 Hz: the connection diagram shows the primaries wired in parallel for 117 VAC and in series for 234 VAC.
What are the dimensions and weight of the 266J6?▾
The ordering table lists mounting style A, dimension A 2.82 in (72 mm), B 1.60 in (41 mm), C 1.69 in (43 mm) and D 2.38 in (60 mm), a mounting hole width of 0.19 in (5 mm), and a weight of 0.7 lb (0.32 kg). Shipping weight is 0.7 lbs (0.32 kg).
Does the 266J6 need an electrostatic shield?▾
No. It uses a dual bobbin design, so no electrostatic shield is required.
What approvals does the 266J6 have?▾
The 266 Series is UL listed (# E207860) Type 3AH and CSA certified (209651); it uses Class B (130 °C) insulation and is UL listed as a Class A (105 °C) design. The part is listed as RoHS and REACH compliant.
Related Products
Save 52%266J48 — Power transformer, chassis mount, 48VA, 48V @ 1A or 24V @ 2A, 266 Series
Hammond Manufacturing · 266J48
Save 52%266JA12 — Power transformer, chassis mount, 12VA, 12V @ 1A or 6V @ 2A, 266 Series
Hammond Manufacturing · 266JA12
Save 52%266J36 — Power transformer, chassis mount, 36VA, 36V @ 1A or 18V @ 2A, 266 Series
Hammond Manufacturing · 266J36
Save 52%266JB12 — Power transformer, chassis mount, 14.4VA, 12V @ 1.2A or 6V @ 2.4A, 266 Series
Hammond Manufacturing · 266JB12
Save 52%266J26 — Power transformer, chassis mount, 26.5VA, 26.8V @ 1A or 13.4V @ 2A, 266 Series
Hammond Manufacturing · 266J26