Hammond 266J24 24VA 24V/12V 1A Dual Secondary Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 24 VA: 24V @ 1A series (C.T.) or 12V @ 2A parallel
- 117/234 VAC, 50/60 Hz dual primary (parallel for 117 V, series for 234 V)
- Secondaries usable center tapped, parallel connected or individually
- Mounting style V; A 3.13 in (80 mm) x B 2.00 in (51 mm) x C 2.75 in (70 mm)
- Open style with minimum 6" long leads
- Dual bobbin design - no electrostatic shield required
- Class B (130 °C) insulation, UL listed as Class A (105 °C); hi-pot tested at 2,000V RMS
- UL listed (# E207860) Type 3AH, CSA certified (209651), RoHS and REACH compliant
The 266J24 is a 24 VA open-style transformer providing 24 V at 1 A in series (center-tapped) or 12 V at 2 A in parallel, from a dual 117/234 VAC primary. It fits equipment builders who need 24 V or 12 V AC at 1 A or 2 A respectively.
The primary accepts 117 or 234 VAC at 50/60 Hz; the 266 Series connection diagrams show the primaries wired in parallel for 117 VAC and in series for 234 VAC. The secondaries can be used as a center tapped secondary (24V @ 1A), parallel connected (12V @ 2A) or used individually, and the unit is designed for use with all windings engaged. Every unit is hi-pot tested at 2,000V RMS.
Construction is open style with minimum 6" long leads and a dual bobbin design, so no electrostatic shield is required. Class B insulation (130 °C) is used for extra protection, and the design is UL listed as a Class A (105 °C) design.
It uses mounting style V; the 266J24B is the style A alternative listed with a 24 V C.T. secondary only. The ordering table gives mounting style V, dimensions A 3.13 in (80 mm), B 2.00 in (51 mm), C 2.75 in (70 mm) and D 2.81 in (71 mm), a mounting hole width of 0.19 in (5 mm) and a weight of 1.6 lb (0.73 kg); shipping weight is 1.6 lbs (0.73 kg).
The series is UL listed (# E207860) Type 3AH and CSA certified (209651), and the 266J24 is listed as RoHS and REACH compliant (UPC 623980223971).
Ideal For
- 24 VAC center-tapped or 12 VAC supply
- Low-voltage AC supply at up to 2 A
- Chassis-mounted equipment for 117 VAC or 234 VAC mains
Overview
| Type | Open style, chassis mount |
| Series | 266 Series |
| Description | Power transformer, chassis mount, 24VA, 24V @ 1A or 12V @ 2A, 266 Series |
| Part Number | 266J24 |
| Series Name | Low Voltage/Filament, Dual Primary & Secondary |
| Manufacturer Short Description | POWER TX 24V@1A 12V@2A |
Dimensions
| Weight | 1.6 lbs (0.73 kg) |
| Dimension A | 3.13 in (80 mm) |
| Dimension B | 2.00 in (51 mm) |
| Dimension C | 2.75 in (70 mm) |
| Dimension D | 2.81 in (71 mm) |
| Mounting Style | V |
| Mounting Hole Width | 0.19 in (5 mm) (drawing: 0.187 in / 5 mm) |
Electrical
| Primary | 117/234 VAC, 50/60 Hz (dual primary) |
| Hi-Pot Test | 2,000V RMS |
| Power Rating | 24 VA |
| Winding Note | Designed for use with all windings engaged |
| Secondary Use | Center tapped secondary, parallel connected or used individually |
| Primary Wiring | Parallel connection for 117 VAC; series connection for 234 VAC |
| Secondary (RMS), Parallel | 12V @ 2A |
| Secondary (RMS), Series (C.T.) | 24V @ 1A |
| Lead Colours (Connection Diagram) | Primary: Blk, Wht, Brn, Orn; Secondary: Red, Blu, Gry, Yel |
Identifiers
| UPC | 623980223971 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 1.6 lbs (0.73 kg) |
Construction & Finish
| Leads | Minimum 6" long leads |
| Style | Open style |
| Insulation | Class B (130 °C) insulation; UL listed as a Class A (105 °C) design |
| Bobbin Design | Dual bobbin - no electrostatic shield required |
Compliance & Certifications
| UL | UL listed (# E207860) Type 3AH |
| CSA | CSA certified (209651) |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What output voltages does the 266J24 provide?▾
With the secondaries in series (center tapped) the 266J24 gives 24V @ 1A; with them in parallel it gives 12V @ 2A. It is rated 24 VA.
Can the 266J24 run on 234 VAC as well as 117 VAC?▾
Yes. The primary is 117/234 VAC, 50/60 Hz: the connection diagram shows the primaries wired in parallel for 117 VAC and in series for 234 VAC.
What are the dimensions and weight of the 266J24?▾
The ordering table lists mounting style V, dimension A 3.13 in (80 mm), B 2.00 in (51 mm), C 2.75 in (70 mm) and D 2.81 in (71 mm), a mounting hole width of 0.19 in (5 mm), and a weight of 1.6 lb (0.73 kg). Shipping weight is 1.6 lbs (0.73 kg).
Does the 266J24 need an electrostatic shield?▾
No. It uses a dual bobbin design, so no electrostatic shield is required.
What approvals does the 266J24 have?▾
The 266 Series is UL listed (# E207860) Type 3AH and CSA certified (209651); it uses Class B (130 °C) insulation and is UL listed as a Class A (105 °C) design. The part is listed as RoHS and REACH compliant.
Related Products
Save 52%266J16 — Power transformer, chassis mount, 16VA, 16V @ 1A or 8V @ 2A, 266 Series
Hammond Manufacturing · 266J16
Save 52%266J24B — Power transformer, chassis mount, 24VA, 24V C.T. @ 1A or -, 266 Series
Hammond Manufacturing · 266J24B
Save 52%266J14 — Power transformer, chassis mount, 14VA, 14V @ 1A or 7V @ 2A, 266 Series
Hammond Manufacturing · 266J14
Save 52%266J25 — Power transformer, chassis mount, 25.2VA, 25.2V @ 1A or 12.6V @ 2A, 266 Series
Hammond Manufacturing · 266J25
Save 52%266J12 — Power transformer, chassis mount, 12.6VA, 12.6V @ 1A or 6.3V @ 2A, 266 Series
Hammond Manufacturing · 266J12