(224) 955-1644
Hammond ManufacturingAuthorized partner store
266J24B 24 VA open-style chassis-mount power transformer with dual primary leads

Hammond 266J24B 24VA 24V Center-Tapped 1A Power Transformer

Hammond Manufacturing|

MPN: 266J24B

|

UPC: 623980036687

In Stock
$14.97

Ships from and sold by A5 IT

Ground Shipping · $18.67Arrives by Monday, Oct 26
Order within 46m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 24 VA rating with a 24V C.T. @ 1A secondary
  • 117/234 VAC, 50/60 Hz dual primary (parallel for 117 V, series for 234 V)
  • Mounting style A; A 3.25 in (83 mm) x B 2.00 in (51 mm) x C 2.00 in (51 mm)
  • Open style with minimum 6" long leads
  • Dual bobbin design - no electrostatic shield required
  • Class B (130 °C) insulation, UL listed as Class A (105 °C); hi-pot tested at 2,000V RMS
  • UL listed (# E207860) Type 3AH, CSA certified (209651), RoHS and REACH compliant

The 266J24B is a 24 VA power transformer with a 117/234 VAC, 50/60 Hz dual primary and a 24 V center-tapped secondary rated 1 A. Unlike most 266 Series models, the ordering table lists no parallel-connection rating for it (shown as "-"), so it is specified purely by its 24 V C.T. output.

The primary accepts 117 or 234 VAC at 50/60 Hz; the 266 Series connection diagrams show the primaries wired in parallel for 117 VAC and in series for 234 VAC. The secondary is rated 24V C.T. @ 1A, and the 266J24B is designed for use with all windings engaged. Every unit is hi-pot tested at 2,000V RMS.

Construction is open style with minimum 6" long leads and a dual bobbin design, so no electrostatic shield is required. Class B insulation (130 °C) is used for extra protection, and the design is UL listed as a Class A (105 °C) design.

It uses mounting style A, while the similarly rated 266J24 uses style V and also offers a 12 V @ 2 A parallel rating. The ordering table gives mounting style A, dimensions A 3.25 in (83 mm), B 2.00 in (51 mm), C 2.00 in (51 mm) and D 2.81 in (71 mm), a mounting hole width of 0.19 in (5 mm) and a weight of 1.6 lb; shipping weight is 1.6 lbs (0.73 kg).

The series is UL listed (# E207860) Type 3AH and CSA certified (209651), and the 266J24B is listed as RoHS and REACH compliant (UPC 623980036687).

Ideal For

  • 24 V center-tapped AC supply at 1 A
  • Chassis-mounted equipment for 117 VAC or 234 VAC mains
  • Designs laid out for mounting style A

Overview

TypeOpen style, chassis mount
Series266 Series
DescriptionPower transformer, chassis mount, 24VA, 24V C.T. @ 1A or -, 266 Series
Part Number266J24B
Series NameLow Voltage/Filament, Dual Primary & Secondary
Manufacturer Short DescriptionPOWER TX 24VCT@1A

Dimensions

Weight1.6 lbs
Dimension A3.25 in (83 mm)
Dimension B2.00 in (51 mm)
Dimension C2.00 in (51 mm)
Dimension D2.81 in (71 mm)
Mounting StyleA
Mounting Hole Width0.19 in (5 mm)

Electrical

Primary117/234 VAC, 50/60 Hz (dual primary)
Hi-Pot Test2,000V RMS
Power Rating24 VA
Winding NoteDesigned for use with all windings engaged
Primary WiringParallel connection for 117 VAC; series connection for 234 VAC
Secondary (RMS), Parallel-
Secondary (RMS), Series (C.T.)24V C.T. @ 1A
Lead Colours (Connection Diagram)Primary: Blk, Wht, Brn, Orn; Secondary: Red, Blu, Gry, Yel

Identifiers

UPC623980036687
UNSPSC39121301

Packaging & Shipping

Shipping Weight1.6 lbs (0.73 kg)

Construction & Finish

LeadsMinimum 6" long leads
StyleOpen style
InsulationClass B (130 °C) insulation; UL listed as a Class A (105 °C) design
Bobbin DesignDual bobbin - no electrostatic shield required

Compliance & Certifications

ULUL listed (# E207860) Type 3AH
CSACSA certified (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output voltages does the 266J24B provide?▾

The 266J24B is rated 24 VA with a 24V C.T. @ 1A secondary. No parallel rating is listed for this part.

Can the 266J24B run on 234 VAC as well as 117 VAC?▾

Yes. The primary is 117/234 VAC, 50/60 Hz: the connection diagram shows the primaries wired in parallel for 117 VAC and in series for 234 VAC.

What are the dimensions and weight of the 266J24B?▾

The ordering table lists mounting style A, dimension A 3.25 in (83 mm), B 2.00 in (51 mm), C 2.00 in (51 mm) and D 2.81 in (71 mm), a mounting hole width of 0.19 in (5 mm), and a weight of 1.6 lb. Shipping weight is 1.6 lbs (0.73 kg).

Does the 266J24B need an electrostatic shield?▾

No. It uses a dual bobbin design, so no electrostatic shield is required.

What approvals does the 266J24B have?▾

The 266 Series is UL listed (# E207860) Type 3AH and CSA certified (209651); it uses Class B (130 °C) insulation and is UL listed as a Class A (105 °C) design. The part is listed as RoHS and REACH compliant.