Hammond 260A6 57VA 740V C.T. 117V Plate & Filament Transformer
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 57 VA rating with 740V C.T. @ 60ma high voltage secondary
- Filament winding: 6.3V C.T. @ 2A
- 117V, 50/60 Hz primary
- Faraday (electrostatic) shield between primary and secondary
- Open frame chassis mount; see PDF drawing for mounting
- Minimum 5" long leads
- REACH and RoHS compliant
The 260A6 is a 57 VA plate and filament transformer with a 740V centre-tapped high voltage secondary at 60 mA (listed in its short description as 370-0-370 at 60 mA) and a 6.3V C.T. filament winding at 2A. Unlike the rest of the 260 Series, it does not have a universal primary: it is a 117V, 50/60 Hz unit, suited to preamps, low power amps and general replacement work.
Construction is economical open frame, chassis mount, and the series is offered in two-hole channel bracket (figure #1) or four-hole (figure #2) styles. For the 260A6, the ordering table refers to its PDF drawing for the mounting detail. The ordering table lists dimensions A 2.5, B 2.155 and C 3 (units not stated in the table), with the remaining dimensions referred to the PDF drawing. Leads are a minimum of 5" long, and the shipping weight is 0.21 lbs (0.10 kg).
The 260A6 includes a Faraday shield between the primary and secondary windings. This electrostatic shield reduces capacitive coupling from the primary, greatly attenuating higher frequency current coupling to the secondaries. The shield lead, the gray wire marked SH, should remain grounded to the mounting bracket and in turn to the chassis.
The 260A6 primary is 117V, 50/60 Hz only; it is the one 260 Series exception to the universal 100/120/220/240 VAC primary. The 260A6 is listed as REACH compliant and RoHS compliant.
Ideal For
- Tube preamp power supplies
- Low power tube amplifiers
- Test equipment power supplies
- General replacement plate and filament transformer
Overview
| Series | 260 Series - Plate & Filament |
| Part Number | 260A6 |
| Long Description | Transformer, plate & filament, 117V, 50/60Hz, 57VA, 740V C.T. @ 60ma. |
| Short Description | 117V,50/60, 370-0-370,60MA |
Dimensions
| Dimension A | 2.5 |
| Dimension B | 2.155 |
| Dimension C | 3 |
Electrical
| Primary | 117V |
| Shielding | Faraday (electrostatic) shield between primary and secondary; gray SH lead grounded to bracket/chassis |
| Power Rating | 57 VA |
| Primary Frequency | 50/60 Hz |
| AC Filament Secondary #2 (RMS) | 6.3V C.T. @ 2A |
| AC Filament Secondary #3 (RMS) | - |
| AC High Voltage Secondary #1 (RMS) | 740V C.T. @ 60ma. |
| High Voltage Secondary (Short Description) | 370-0-370, 60MA |
Identifiers
| UPC | 623980241890 |
| UNSPSC | 39121301 |
Rack Mounting
| Mounting Type | Chassis mount |
| Figure # Or PDF File | See PDF |
Packaging & Shipping
| Shipping Weight | 0.21 lbs (0.10 kg) |
Construction & Finish
| Lead Length | Minimum 5 in |
| Construction | Open frame |
Compliance & Certifications
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What are the secondary windings of the 260A6?▾
A 740V C.T. @ 60ma high voltage secondary and filament winding of 6.3V C.T. @ 2A.
What mains voltages can the 260A6 run from?▾
The 260A6 is a 117V, 50/60 Hz unit; it is the exception to the 260 Series universal primary.
Does the 260A6 have an electrostatic shield?▾
Yes. It includes a Faraday shield between primary and secondary; the gray SH lead should stay grounded to the mounting bracket and chassis.
How is the 260A6 mounted?▾
For the 260A6, the ordering table refers to its PDF drawing for the mounting detail. The ordering table lists dimensions A 2.5, B 2.155 and C 3 (units not stated in the table), with the remaining dimensions referred to the PDF drawing.
How much does the 260A6 weigh?▾
The shipping weight is 0.21 lbs (0.10 kg).
Related Products
Save 52%260A — Transformer, plate & filament, universal primary, 22VA, 400V C.T. @ 40ma.
Hammond Manufacturing · 260A
Save 52%260C — Transformer, plate & filament, universal primary, 65VA, 500V C.T @ 85ma..
Hammond Manufacturing · 260C
Save 52%260E — Transformer, plate & filament, universal primary, 80VA, 450V C.T. @ 115ma.
Hammond Manufacturing · 260E
Save 52%260G — Transformer, plate & filament, universal primary, 175VA, 550V C.T. @ 230ma.
Hammond Manufacturing · 260G
Save 52%260J — Transformer, plate & filament, universal primary, 152VA, 650V C.T. @ 173ma.
Hammond Manufacturing · 260J