(224) 955-1644
Hammond ManufacturingAuthorized partner store
182D110 15 VA toroidal power transformer with dual 110 V secondaries

Hammond 182D110 15VA Toroidal Transformer, Dual 110V Secondaries

Hammond Manufacturing|

MPN: 182D110

|

UPC: 623980271934

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing 182D110.

224-955-1644
Ground Shipping · $16.89Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • 15 VA with dual 110 V secondaries
  • Series: 220 V C.T. @ 68 mA; parallel: 110 V @ 136 mA
  • Dual 117/234 VAC, 50/60 Hz primary
  • 2.70 in (69 mm) OD x 1.25 in (32 mm) high toroid
  • 8-32 x 1.50 in centre bolt, rubber pads and centering washer included
  • 4,000 V RMS Hi-Pot; CSA, UL recognized, CE
  • Manufacturer replacement part: 1182D110

The 182D110 is a 15 VA toroidal transformer in the 182 Series with dual secondaries that can be connected in series for 220 V center-tapped at 68 mA, or in parallel for 110 V at 136 mA. Its dual 117/234 VAC primary operates on 50 or 60 Hz, so one part can serve equipment built for either mains voltage.

This part is marked REPLACE WITH 1182D110. The 182 Series is being discontinued as a stocked line and is available while quantities last, with the 1182 Series as its replacement.

Physically, the 182D110 is a 2.70 in (69 mm) diameter toroid, 1.25 in (32 mm) high, with an open centre. It is secured by one centre bolt: 8-32 thread, 1.50 in (38 mm) long, with a top steel washer and top and bottom rubber washers. Units of 160 VA and under ship with two rubber insulating pads, a metal centering washer and all mounting hardware. The series table lists 0.76 lbs; shipping weight is 0.8 lbs (0.36 kg).

Flexible leads are at least 8 in long, and the manufacturer notes that units are designed to have all windings engaged. Primary to secondary Hi-Pot testing is 4,000 V RMS. Approvals are CSA C22.2 #66 (file 209651), UL recognized to UL506 (file E207860) and CE to IEC950; the part is RoHS and REACH compliant. Because toroids can draw a large inrush current at switch-on, use a slow-blow fuse, time-delay breaker or soft start on the supply.

Ideal For

  • Low-current 110 V or 220 V C.T. auxiliary supplies
  • Equipment serving 117 V and 234 V markets
  • Replacement parts for existing 182 Series designs

Mounting

Potted CenterNo
Supplied WithTwo rubber insulating pads, one metal centering washer and all mounting hardware (160VA and under)
Toroid CenterOpen
Mounting StyleCenter single hole mounting
Mounting Hardware Length1.50 in (38 mm)
Mounting Hardware Thread8-32
Top Steel Mounting Washer With Top & Bottom Rubber WasherYes

Overview

Series182 Series - Toroidal L.V., Chassis Mount (15 VA to 1500 VA)
Part Number182D110
Replacement Part1182D110
Availability NoteSeries will soon be discontinued as a stocked series; available while quantities last; replaced with 1182 Series
Short DescriptionREPLACE WITH 1182D110

Dimensions

Height1.25 in (32 mm)
Outside Diameter2.70 in (69 mm)

Electrical

PrimaryDual 117/234 VAC, 50/60 Hz
WindingsDesigned to have all windings engaged
Hi-Pot Test4,000V RMS between primary & secondary
Power Rating15 VA
Primary Wiring117 V: parallel connection; 234 V: series connection
Inrush Current GuidanceConsider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line
Dual Or Single SecondaryDual
Secondary (RMS) - Series220V C.T. @ 68ma
Secondary (RMS) - Parallel110V @ 136ma

Identifiers

UPC623980271934
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.8 lbs (0.36 kg)
Weight (Series Table)0.76 lbs

Construction & Finish

LeadsMinimum 8" long flexible leads
DesignToroidal - low profile, lightweight, cool running

Compliance & Certifications

CECertified to IEC950
ULRecognized to UL506 - UL file #E207860
CSACertified to C22.2 #66 - CSA file #209651
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What outputs can the 182D110 provide?▾

220 V center-tapped at 68 mA with secondaries in series, or 110 V at 136 mA in parallel.

What is the replacement for the 182D110?▾

The manufacturer lists 1182D110.

What size is the 182D110?▾

2.70 in (69 mm) outside diameter and 1.25 in (32 mm) high.

Does it come with mounting hardware?▾

Yes. It uses an 8-32 bolt 1.50 in long; units 160 VA and under include two rubber insulating pads, one metal centering washer and all mounting hardware.

Is the primary 50 Hz compatible?▾

Yes, the dual 117/234 VAC primary is rated for 50/60 Hz operation.