Hammond 182B240 15VA Toroidal Transformer, 240V Single Secondary
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 15 VA toroidal transformer with single 240 V secondary at 63 mA
- Dual 117/234 VAC primary for 50/60 Hz operation
- Compact 2.70 in (69 mm) diameter, 1.25 in (32 mm) height
- Single centre-bolt mounting with 8-32 x 1.50 in hardware included
- 4,000 V RMS primary-to-secondary Hi-Pot test
- CSA C22.2 #66, UL506 recognized, CE to IEC950
- Manufacturer replacement: 1182B240
The 182B240 is a 15 VA toroidal power transformer from the 182 Series of low voltage, chassis-mount toroids. It pairs a dual 117/234 VAC, 50/60 Hz primary with a single 240 V secondary rated at 63 mA, giving designers a small, low-profile source of 240 V for bias, sensing or low-current auxiliary circuits.
The manufacturer lists this part as REPLACE WITH 1182B240, and the 182 Series is being discontinued as a stocked series, available while quantities last and superseded by the 1182 Series. Buyers maintaining existing equipment built around the 182B240 can use this listing to confirm the original specifications.
The toroid measures 2.70 in (69 mm) in outside diameter and 1.25 in (32 mm) high, with an open (non-potted) centre. It mounts with a single centre bolt; this size uses 8-32 hardware 1.50 in (38 mm) long, supplied with a top steel mounting washer plus top and bottom rubber washers. As a 160 VA-and-under unit it ships with two rubber insulating pads, one metal centering washer and all mounting hardware. Weight is 0.76 lbs in the series table and shipping weight is 0.8 lbs (0.36 kg).
Leads are flexible and at least 8 in long. The primary is wired in parallel for 117 V or in series for 234 V. Each 182 Series unit is Hi-Pot tested at 4,000 V RMS between primary and secondary, CSA certified to C22.2 #66 (file 209651), UL recognized to UL506 (file E207860) and CE certified to IEC950. The part is also RoHS and REACH compliant.
Ideal For
- Low-current 240 V auxiliary supplies
- Maintenance of equipment built with the 182 Series
- Compact chassis-mounted power in 117 V or 234 V equipment
Mounting
| Potted Center | No |
| Supplied With | Two rubber insulating pads, one metal centering washer and all mounting hardware (160VA and under) |
| Toroid Center | Open |
| Mounting Style | Center single hole mounting |
| Mounting Hardware Length | 1.50 in (38 mm) |
| Mounting Hardware Thread | 8-32 |
| Top Steel Mounting Washer With Top & Bottom Rubber Washer | Yes |
Overview
| Series | 182 Series - Toroidal L.V., Chassis Mount (15 VA to 1500 VA) |
| Part Number | 182B240 |
| Replacement Part | 1182B240 |
| Availability Note | Series will soon be discontinued as a stocked series; available while quantities last; replaced with 1182 Series |
| Short Description | REPLACE WITH 1182B240 |
Dimensions
| Height | 1.25 in (32 mm) |
| Outside Diameter | 2.70 in (69 mm) |
Electrical
| Primary | Dual 117/234 VAC, 50/60 Hz |
| Windings | Designed to have all windings engaged |
| Hi-Pot Test | 4,000V RMS between primary & secondary |
| Power Rating | 15 VA |
| Primary Wiring | 117 V: parallel connection; 234 V: series connection |
| Inrush Current Guidance | Consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line |
| Dual Or Single Secondary | Single |
| Secondary (RMS) - Series | - |
| Secondary (RMS) - Parallel | 240V @ 63ma |
Identifiers
| UPC | 623980271958 |
| UNSPSC | 39121301 |
Packaging & Shipping
| Shipping Weight | 0.8 lbs (0.36 kg) |
| Weight (Series Table) | 0.76 lbs |
Construction & Finish
| Leads | Minimum 8" long flexible leads |
| Design | Toroidal - low profile, lightweight, cool running |
Compliance & Certifications
| CE | Certified to IEC950 |
| UL | Recognized to UL506 - UL file #E207860 |
| CSA | Certified to C22.2 #66 - CSA file #209651 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What replaces the 182B240?▾
The manufacturer lists the replacement as 1182B240; the 182 Series is being replaced by the 1182 Series.
What is the secondary rating of the 182B240?▾
A single 240 V secondary rated at 63 mA, for 15 VA.
Can the 182B240 run on 234 V mains?▾
Yes. The dual primary is wired in parallel for 117 V or in series for 234 V, 50/60 Hz.
What mounting hardware comes with it?▾
An 8-32 center bolt 1.50 in long, with two rubber insulating pads and one metal centering washer, as supplied with 182 Series units of 160 VA and under.
What fuse should I use with a toroidal transformer?▾
The manufacturer notes toroids can draw high inrush current and recommends a slow-blow fuse, time delayed circuit breaker or soft start circuitry.
Related Products

182D110 — Replace With 1182D110
Hammond Manufacturing · 182D110
Save 52%182D117 — Replace With 1182D117
Hammond Manufacturing · 182D117
Save 52%182D240 — Replace With 1182D240
Hammond Manufacturing · 182D240
Save 52%182E110 — Replace With 1182E110
Hammond Manufacturing · 182E110

182E117 — Replace With 1182E117
Hammond Manufacturing · 182E117