Hammond 178GT 1500VA Toroidal Isolation Transformer, 120V Plug-In
Ships from and sold by A5 IT
Available on backorder — ships as soon as stock arrives
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 1500VA toroidal isolation transformer, 120VAC primary to 120VAC secondary, 50/60 Hz
- Toroidal core for high isolation, low noise, light weight, cool operation and low profile
- Output: Two standard 3-wire grounded receptacles (NEMA 5-15R)
- Input: North American NEMA 5-15P 3-wire grounded plug and cord
- Rocker lighted on-off switch and 15 amp circuit breaker protected output
- Ventilated black steel case, 12.50 in (318 mm) x 9.00 in (229 mm) x 5.00 in (127 mm)
- C UL & UL listed (File #E211544); RoHS and REACH compliant; indoor use only
The Hammond 178GT is a 1500VA plug-in toroidal isolation transformer with a 120VAC primary and 120VAC secondary, rated for 50 or 60 Hz. It provides circuit isolation for integrators, technicians and engineers who want isolated, low-noise 120V power for connected equipment without hard wiring.
The toroidal design is chosen for high isolation, low noise, light weight, cool operation and a low profile. The unit is built in a ventilated black steel case with perforated holes, and includes a rocker lighted on-off switch and a circuit breaker protected output. The 178GT is the 1500VA model, the largest in the 178 Series, housed in a 12.50 in by 9.00 in by 5.00 in case with a 15 amp circuit breaker on the output.
The input (primary) connects through a standard North American NEMA 5-15P 3-wire grounded plug; the series specification lists a 5 foot cord, while the part drawing calls out a 6 foot cord. The output (secondary) is two standard 3-wire grounded receptacles (NEMA 5-15R). Overall dimensions are 12.50 in (318 mm) long, 9.00 in (229 mm) wide and 5.00 in (127 mm) high, and the shipping weight is 37.5 lbs (17.01 kg).
The 178GT carries the North American Mark of Safety, C UL and UL listed under File #E211544, and is RoHS and REACH compliant. It is for indoor use only and does not convert line frequency. Because toroidal transformers can draw a high magnetizing inrush when first energized, consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line.
Ideal For
- Isolating 120V loads up to 1500VA
- Low-noise isolated power for larger electronics setups
- Circuit isolation for bench and lab equipment
Controls
| On-Off Switch | Rocker lighted on-off switch |
Overview
| Series | 178 Series, TOROIDAL Isolation (120VAC to 120VAC) |
| Description | Isolation transformer, toroidal, plug-in 120VAC to 120VAC, 1500VA , 178 Series |
| Product Type | Isolation transformer, toroidal, plug-in |
| Short Description | 1500VA PLUG IN ISOLATED |
Dimensions
| Overall Width | 9.00 in (229 mm) |
| Drawing Length | 12.500 in (317.50 mm) |
| Overall Height | 5.00 in (127 mm) |
| Overall Length | 12.50 in (318 mm) |
| Drawing Width Dimensions | 9.125 in (231.78 mm); 9.333 in (237.07 mm) |
| Drawing Height (Section A-A) | 5.057 in (128.45 mm) |
Electrical
| Frequency | 50/60 Hz |
| Isolation | Provides circuit isolation |
| Power Rating | 1500 VA |
| Output Protection | 15 amp circuit breaker |
| Inrush Current Note | Toroidal transformers can draw high magnetizing current when first energized, limited only by the low DC resistance of the primary; the overload rarely lasts longer than half a cycle, so a slow-blow fuse, time delayed circuit breaker or other soft start circuitry on the supply line should be considered |
| Frequency Conversion | Does NOT convert line frequency |
| Primary (Input) Voltage | 120VAC |
| Secondary (Output) Voltage | 120VAC |
Connections
| Input Plug | Standard North American 3-wire grounded plug (NEMA 5-15P) |
| Number Of Outlets | 2 |
| Output Receptacle | Two standard 3-wire grounded receptacles (NEMA 5-15R) |
| Input Cord Length (Part Drawing) | 6 foot |
| Input Cord Length (Series Specification) | 5 foot |
Identifiers
| UPC | 623980008400 |
| UNSPSC | 39121301 |
| Part Number | 178GT |
Packaging & Shipping
| Shipping Weight | 37.5 lbs (17.01 kg) |
Construction & Finish
| Case | Ventilated black steel case with perforated holes |
| Core | Toroidal transformer: high isolation, low noise, light weight, cool operation, low profile |
Environmental & Protection
| Location | Indoor use only |
Compliance & Certifications
| RoHS Compliant | Yes |
| Safety Listing | North American Mark of Safety - C UL & UL listed (File #E211544) |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What voltage does the 178GT accept and supply?▾
It is a 120VAC to 120VAC isolation transformer (primary 120VAC, secondary 120VAC) for 50/60 Hz operation. It does not change voltage or convert line frequency.
How is the 178GT connected?▾
The input uses a standard North American NEMA 5-15P 3-wire grounded plug (the series specification lists a 5 foot cord; the drawing shows a 6 foot cord). The output is two standard 3-wire grounded receptacles (NEMA 5-15R).
Why might the upstream breaker trip when I switch it on?▾
Toroidal transformers can draw high magnetizing current when first energized, limited only by the low DC resistance of the primary. The overload rarely lasts longer than half a cycle, so a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line is recommended.
What protection is built into the 178GT?▾
The output is circuit breaker protected; the part drawing shows a 15 amp circuit breaker. It also has a rocker lighted on-off switch.
How big and heavy is the 178GT?▾
Overall dimensions are 12.50 in (318 mm) long, 9.00 in (229 mm) wide and 5.00 in (127 mm) high. Shipping weight is 37.5 lbs (17.01 kg).
Is it certified and can it be used outdoors?▾
It is C UL and UL listed (File #E211544) and RoHS and REACH compliant. It is for indoor use only.
Related Products
Save 52%178FT — Isolation transformer, toroidal, plug-in 120VAC to 120VAC, 1000VA , 178 Series
Hammond Manufacturing · 178FT
Save 52%178ET — Isolation transformer, toroidal, plug-in 120VAC to 120VAC, 750VA , 178 Series
Hammond Manufacturing · 178ET
Save 52%178DT — Isolation transformer, toroidal, plug-in 120VAC to 120VAC, 500VA , 178 Series
Hammond Manufacturing · 178DT
Save 52%178CT — Isolation transformer, toroidal, plug-in 120VAC to 120VAC, 250VA , 178 Series
Hammond Manufacturing · 178CT