Hammond 178DT 500VA toroidal plug-in isolation transformer, 120VAC to 120VAC, in ventilated black steel case with lighted switch and NEMA 5-15R outlets

Hammond 178DT 500VA Toroidal Isolation Transformer, 120V Plug-In

Hammond Manufacturing|

MPN: 178DT

|

UPC: 623980093949

In Stock
$253.75

Ships from and sold by A5 IT

Ground Shipping · $26.11Arrives by Monday, Oct 26
Order within 47m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 500VA toroidal isolation transformer, 120VAC primary to 120VAC secondary, 50/60 Hz
  • Toroidal core for high isolation, low noise, light weight, cool operation and low profile
  • Output: Two standard 3-wire grounded receptacles (NEMA 5-15R)
  • Input: North American NEMA 5-15P 3-wire grounded plug and cord
  • Rocker lighted on-off switch and 5 amp circuit breaker protected output
  • Ventilated black steel case, 9.00 in (229 mm) x 6.00 in (152 mm) x 4.00 in (102 mm)
  • C UL & UL listed (File #E211544); RoHS and REACH compliant; indoor use only

The Hammond 178DT is a 500VA plug-in toroidal isolation transformer with a 120VAC primary and 120VAC secondary, rated for 50 or 60 Hz. It provides circuit isolation for integrators, technicians and engineers who want isolated, low-noise 120V power for connected equipment without hard wiring.

The toroidal design is chosen for high isolation, low noise, light weight, cool operation and a low profile. The unit is built in a ventilated black steel case with perforated holes, and includes a rocker lighted on-off switch and a circuit breaker protected output. The 178DT doubles capacity to 500VA with only a longer 9.00 in case, keeping the 6.00 in width and 4.00 in height; the output uses a 5 amp circuit breaker.

The input (primary) connects through a standard North American NEMA 5-15P 3-wire grounded plug; the series specification lists a 5 foot cord, while the part drawing calls out a 6 foot cord. The output (secondary) is two standard 3-wire grounded receptacles (NEMA 5-15R). Overall dimensions are 9.00 in (229 mm) long, 6.00 in (152 mm) wide and 4.00 in (102 mm) high, and the shipping weight is 14 lbs (6.35 kg).

The 178DT carries the North American Mark of Safety, C UL and UL listed under File #E211544, and is RoHS and REACH compliant. It is for indoor use only and does not convert line frequency. Because toroidal transformers can draw a high magnetizing inrush when first energized, consider a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line.

Ideal For

  • Isolating 120V equipment up to 500VA
  • Low-noise 120V power for audio or computer gear
  • Circuit isolation for test benches

Controls

On-Off SwitchRocker lighted on-off switch

Overview

Series178 Series, TOROIDAL Isolation (120VAC to 120VAC)
DescriptionIsolation transformer, toroidal, plug-in 120VAC to 120VAC, 500VA , 178 Series
Product TypeIsolation transformer, toroidal, plug-in
Short Description500VA PLUG IN ISOLATED

Dimensions

Overall Width6.00 in (152 mm)
Drawing Length9.000 in (228.60 mm)
Overall Height4.00 in (102 mm)
Overall Length9.00 in (229 mm)
Drawing Width Dimensions6.125 in (155.58 mm); 6.333 in (160.87 mm)
Drawing Height (Section A-A)4.057 in (103.05 mm)

Electrical

Frequency50/60 Hz
IsolationProvides circuit isolation
Power Rating500 VA
Output Protection5 amp circuit breaker
Inrush Current NoteToroidal transformers can draw high magnetizing current when first energized, limited only by the low DC resistance of the primary; the overload rarely lasts longer than half a cycle, so a slow-blow fuse, time delayed circuit breaker or other soft start circuitry on the supply line should be considered
Frequency ConversionDoes NOT convert line frequency
Primary (Input) Voltage120VAC
Secondary (Output) Voltage120VAC

Connections

Input PlugStandard North American 3-wire grounded plug (NEMA 5-15P)
Number Of Outlets2
Output ReceptacleTwo standard 3-wire grounded receptacles (NEMA 5-15R)
Input Cord Length (Part Drawing)6 foot
Input Cord Length (Series Specification)5 foot

Identifiers

UPC623980093949
UNSPSC39121301
Part Number178DT

Packaging & Shipping

Shipping Weight14 lbs (6.35 kg)

Construction & Finish

CaseVentilated black steel case with perforated holes
CoreToroidal transformer: high isolation, low noise, light weight, cool operation, low profile

Environmental & Protection

LocationIndoor use only

Compliance & Certifications

RoHS CompliantYes
Safety ListingNorth American Mark of Safety - C UL & UL listed (File #E211544)
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What voltage does the 178DT accept and supply?▾

It is a 120VAC to 120VAC isolation transformer (primary 120VAC, secondary 120VAC) for 50/60 Hz operation. It does not change voltage or convert line frequency.

How is the 178DT connected?▾

The input uses a standard North American NEMA 5-15P 3-wire grounded plug (the series specification lists a 5 foot cord; the drawing shows a 6 foot cord). The output is two standard 3-wire grounded receptacles (NEMA 5-15R).

Why might the upstream breaker trip when I switch it on?▾

Toroidal transformers can draw high magnetizing current when first energized, limited only by the low DC resistance of the primary. The overload rarely lasts longer than half a cycle, so a slow-blow fuse, time delayed circuit breaker or soft start circuitry on the supply line is recommended.

What protection is built into the 178DT?▾

The output is circuit breaker protected; the part drawing shows a 5 amp circuit breaker. It also has a rocker lighted on-off switch.

How big and heavy is the 178DT?▾

Overall dimensions are 9.00 in (229 mm) long, 6.00 in (152 mm) wide and 4.00 in (102 mm) high. Shipping weight is 14 lbs (6.35 kg).

Is it certified and can it be used outdoors?▾

It is C UL and UL listed (File #E211544) and RoHS and REACH compliant. It is for indoor use only.