164E12 low-profile 2.4VA PCB mount power transformer, 115V primary, 12.6V C.T. @ .2A secondary

Hammond 164E12 2.4VA 12.6V Center-Tapped PCB Transformer, 115V Primary

Hammond Manufacturing|

MPN: 164E12

|

UPC: 623980260082

In Stock
$6.46

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Monday, Oct 26
Order within 1h 4m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 2.4VA rating: 12.6V C.T. @ .2A with secondaries in series, 6.3V @ .4A in parallel
  • Single 115V primary for 50/60 Hz operation
  • No mounting hardware required at 2.4VA; industry-standard P.C. board pin spacing
  • Low-profile split bobbin, 1.38 x 1.13 x 1.19 in (L x W x H)
  • Dual non-concentric secondaries; low coupling, no electrostatic shield required
  • Class B 130 degrees C insulation, 2,500V RMS hipot
  • c UL us recognized; RoHS and REACH compliant

Designed for printed circuit boards, the 164E12 is a low-profile 2.4VA power transformer with an economical single 115V primary that operates on 50 or 60 Hz. Engineers specifying low-voltage AC for board-level circuits get a 12.6V centre-tapped secondary from a split bobbin design. The secondaries produce 12.6V centre-tapped at 0.2A in series, or 6.3V at 0.4A when the two windings are paralleled.

The secondary is made up of two windings that are wound non-concentrically on the split bobbin. That arrangement keeps primary-to-secondary coupling low, so no electrostatic shield is required. Insulation is Class B (130 degrees C) and the unit is hipot rated at 2,500V RMS. Note that the design requires all windings to be used, so connect both secondaries in series or in parallel.

The E-size body measures 1.38 in long by 1.13 in wide by 1.19 in high and weighs 0.25 lb per the series specification sheet. At 2.4VA it needs no mounting hardware: the unit is held by its P.C. board pins, which use industry-standard pin spacing.

The transformer is c UL us recognized and listed as RoHS and REACH compliant. Where a design must run from 115V or 230V, the dual-primary equivalent in the same series is 162E12.

Ideal For

  • Low-voltage AC supply on printed circuit boards
  • Board-level designs needing 12.6V centre-tapped or 6.3V secondary
  • OEM equipment powered from 115V, 50/60 Hz mains
  • Low-profile PCB layouts with limited height

Mounting

Mounting TypeP.C. board mount, industry standard pin spacing
Mounting HardwareNone required (2.4 VA size)

Overview

Series162-164 Series (164 = single primary 115V)
Part Number164E12
Product TypeTransformer, low voltage PCB mount, low profile
Short DescriptionPOWER TX 2.4VA 115V 50/60HZ
Dual Primary (115/230V) Equivalent162E12

Dimensions

Size LetterE
Width (W) - Spec Sheet1.13"
Height (H) - Spec Sheet1.19"
Length (L) - Spec Sheet1.38"
Dimension A - Spec Sheet0.25"
Dimension B - Spec Sheet0.25"
Dimension C - Spec Sheet1.2"

Electrical

Hipot2,500V RMS
Frequency50/60 Hz
Primary Voltage115V (single primary)
Insulation ClassClass B, 130 degrees C
Power Rating (VA)2.4
Electrostatic ShieldNot required (low primary to secondary coupling)
Secondary (RMS) Series12.6V C.T. @ .2A
Secondary ConfigurationDual winding secondaries, non-concentrically wound; all windings must be used
Secondary (RMS) Parallel6.3V @ .4A

Identifiers

UPC623980260082
UNSPSC39121301

Packaging & Shipping

Shipping Weight0.31 lbs (0.14 kg)

Construction & Finish

DesignLow profile, split bobbin
Unit Weight - Spec Sheet0.25 lbs

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
Agency Recognitionc UL us recognized

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output voltage and current does the 164E12 provide?▾

With the two secondaries connected in series it provides 12.6V C.T. @ .2A; connected in parallel it provides 6.3V @ .4A. The transformer is rated 2.4VA.

Can I use only one of the secondary windings?▾

The series is designed so that all windings must be used, so connect both secondary windings, either in series for the centre-tapped output or in parallel for the lower-voltage, higher-current output.

What input voltage does the 164E12 accept?▾

It has a single 115V primary and operates on 50/60 Hz. For universal 115/230V dual-primary operation, the matching part in the series is 162E12.

How is it mounted?▾

It is a P.C. board mount transformer with industry-standard pin spacing. At 2.4VA no mounting hardware is required.

What are the dimensions of the 164E12?▾

The series specification sheet lists the E size at 1.38 in L x 1.13 in W x 1.19 in H, with a weight of 0.25 lb. Shipping weight is 0.31 lbs (0.14 kg).

What insulation and safety ratings does it carry?▾

Class B insulation rated 130 degrees C, a 2,500V RMS hipot, and c UL us recognition. It is also listed as RoHS and REACH compliant.