(224) 955-1644
Hammond ManufacturingAuthorized partner store
162E120 low-profile PCB mount power transformer, 2.4VA, 115/230V dual primary, 120V center-tapped secondary

Hammond 162E120 2.4VA 120V Center-Tapped PCB Transformer, 115/230V

Hammond Manufacturing|

MPN: 162E120

|

UPC: 623980261355

In Stock
$6.56

Ships from and sold by A5 IT

Ground Shipping · $16.89Arrives by Tuesday, Oct 27
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 2.4 VA rating with 120V C.T. @ .02A series or 60V @ .04A parallel secondary (RMS)
  • Universal dual primary for 115V or 230V input, 50/60 Hz operation
  • Low profile: 1.375" L x 1.125" W x 1.170" H per drawing
  • No mounting hardware required at the 2.4 VA size; PC board pins use industry standard spacing
  • Class B insulation (130 degrees C) and 2,500V RMS hipot rating
  • Split bobbin with non-concentric dual secondaries; no electrostatic shield required
  • cULus recognized; RoHS and REACH compliant

The 162E120 is a low-profile, PC board mount power transformer from the 162-164 Series, rated at 2.4 VA with a universal dual primary for 115V or 230V operation at 50/60 Hz. It is intended for designers and OEM engineers who need a low-voltage AC source mounted directly on a printed circuit board. The 120V center-tapped series connection delivers .02A, and wiring the two secondaries in parallel gives 60V at .04A.

Construction uses a low profile, split bobbin design with dual winding secondaries that are non-concentrically wound. Primary to secondary coupling is low, so no electrostatic shield is required. Insulation is Class B (130 degrees C) and the unit is hipot rated at 2,500V RMS; the drawing lists a primary-to-secondary hipot test of 2500V, 60Hz for 1 second. Pin numbers are embossed on the bobbin flange. The units are designed so that all windings must be used.

Per the part drawing, the 162E120 measures 1.375" long, 1.125" wide and 1.170" high (inches, ±0.030"), with a series table nominal size of 1.38 x 1.13 x 1.19 in. The series table lists a weight of 0.25 lbs, and the listed shipping weight is 0.25 lbs (0.11 kg). At the 2.4 VA size no mounting hardware is required: the transformer is held by its PC board pins, which use industry standard pin spacing.

Electrically, the drawing shows two 115V primary windings (pins 1-2 and 3-4) and two 60V secondary windings (pins 5-6 and 7-8) marked 20mA each. Test criteria include a maximum excitation current of 26.4mA at 115V, 60Hz, and a secondary no-load voltage of 73.21V ±2% per winding. The part is cULus recognized and is listed as RoHS and REACH compliant. A single-primary 115V version of the same rating is available as the 164E120.

Ideal For

  • Low-voltage 120V center-tapped AC supply on printed circuit boards
  • 60V parallel-connected secondary supply at .04A
  • PCB-mounted power for equipment running on 115V or 230V, 50/60 Hz
  • Designs needing low primary-to-secondary coupling without an electrostatic shield

Mounting

MountingPC board mount; no mounting hardware required (1.1 and 2.4 VA sizes)
Pin SpacingIndustry standard
Pin IdentificationPin numbers embossed on bobbin flange

Overview

Series162-164 Series (162 = dual primary 115/230V)
DescriptionTransformer, low voltage PCB mount, low profile, 115/230V, 2.4VA, 120V C.T. @ .02A
Product TypeTransformer, low voltage PCB mount, low profile
Short DescriptionPOWER TX 2.4VA 115/230
Single-Primary 115V Equivalent164E120

Dimensions

Width (Drawing, W)1.125" ±0.030
Drawing Dimension A0.250" ±0.030
Drawing Dimension B0.250" ±0.030
Drawing Dimension C1.220" ±0.030
Drawing Dimension D0.041" x 0.018" ±0.005
Drawing Dimension E0.735" ±0.030
Drawing Dimension F0.040" ±0.005
Drawing Dimension G0.234" ±0.005
Drawing Dimension J0.290" ±0.030
Drawing Dimension K0.530" ±0.030
Drawing Dimension M0.350" ±0.030
Drawing Dimension N0.970" ±0.030
Height (Drawing, H)1.170" ±0.030
Length (Drawing, L)1.375" ±0.030
Series Table Dimension A0.25 in
Series Table Dimension B0.25 in
Series Table Dimension C1.2 in
Nominal Size (Series Table, L X W X H)1.38 x 1.13 x 1.19 in

Electrical

Frequency50/60 Hz
Hipot TestPrimary - secondary 2500V, 60Hz, 1 sec
Winding UseAll windings must be used
Hipot Rating2,500V RMS
Power Rating2.4 VA
Primary Voltage115/230V (universal dual primary)
Insulation ClassClass B, 130 degrees C
Electrostatic ShieldNot required (low primary to secondary coupling)
Secondary (RMS) Series120V C.T. @ .02A
Excitation Current (Iex)26.4mA max @ 115V, 60Hz, pin 1 - pin 2
Rating Marked On Drawing50/60Hz, 2.5VA
Secondary (RMS) Parallel60V @ .04A
DC Resistance @ 20°C, Pins 1-2509.2 Ω ±20%
DC Resistance @ 20°C, Pins 3-4645.8 Ω ±20%
DC Resistance @ 20°C, Pins 5-6204.8 Ω ±20%
DC Resistance @ 20°C, Pins 7-8266.7 Ω ±20%

Identifiers

UPC623980261355
UNSPSC39121301
Part Number162E120

Packaging & Shipping

Shipping Weight0.25 lbs (0.11 kg)
Weight (Series Table)0.25 lbs

Construction & Finish

DesignLow profile, split bobbin
SecondariesDual winding secondaries, non-concentrically wound

Compliance & Certifications

RoHS CompliantYes
REACH CompliantYes
Safety Recognitionc UL us recognized

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What output voltages does the 162E120 provide?▾

Connected in series the secondaries give 120V C.T. @ .02A (RMS); connected in parallel they give 60V @ .04A. Each of the two secondary windings is marked 60V 20mA on the drawing.

Can the 162E120 run on both 115V and 230V?▾

Yes. The 162 series uses a universal dual primary for 115/230V, with two 115V primary windings on pins 1-2 and 3-4, and operates on 50/60 Hz. The single-primary 115V version is the 164E120.

Does it need mounting hardware?▾

At the 2.4 VA size no mounting hardware is required: the transformer is held by its PC board pins, which use industry standard pin spacing.

How large is the 162E120?▾

The drawing gives 1.375" long x 1.125" wide x 1.170" high (±0.030"). The series table lists a nominal 1.38 x 1.13 x 1.19 in and a weight of 0.25 lbs.

What insulation and safety ratings does it carry?▾

Class B insulation (130 degrees C), a 2,500V RMS hipot rating (tested primary to secondary at 2500V, 60Hz for 1 second), and c UL us recognition. It is listed as RoHS and REACH compliant.

Can I leave one secondary winding unused?▾

No. The series specification states the units are designed so that all windings must be used, so connect both secondaries in series or in parallel.