Hammond 1582T6D1 1U 6-Outlet Rack PDU, 15A Locking Plug
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 1U horizontal 19" rackmount basic PDU with six front-facing NEMA 5-15R outlets and no rear outlets
- 15 ft cord with NEMA L5-15P locking plug for a secure source connection
- Rated 15 A, 120/125 VAC single-phase; includes a 15 Amp, 125 VAC resettable circuit breaker
- Red power indicator light (no on/off switch) to confirm the panel is energized
- Heavy-duty 14 gauge 14/3 SJT cord with integral moulded plug for extreme temperature ranges
- ASA 61 grey painted steel front and back, powder coat compliant with Greenguard indoor air quality guidelines
- UL Recognized to UL1363 and CSA Certified to C22.2 No. 21-95 & 42-99, UL file E166039
- TAA-compliant, RoHS, REACH and USMCA compliant; manufactured in North America
The 1582T6D1 is a 1U horizontal 19-inch rack mount basic power distribution unit that feeds six NEMA 5-15R outlets from the front of the panel. It is aimed at IT and AV integrators, electricians, OEM builders and facilities teams who need straightforward 15 A, single-phase power distribution inside a rack, cabinet or open-frame relay rack without metering or network management.
Power reaches the unit through an integral 15 ft cord terminated in a NEMA L5-15P locking plug, so the connection stays seated in vibration-prone or high-traffic installations. The cord is heavy-duty 14 gauge, 14/3 SJT type for extreme temperature ranges with an integral moulded plug, and a 15 Amp, 125 VAC resettable circuit breaker is built in to guard against accidental overload. A red power indicator light shows live status; this version has no on/off rocker switch, so downstream equipment is not switched at the panel.
Overall dimensions are 1.72 in (44 mm) high by 19.00 in (483 mm) wide by 2.66 in (68 mm) deep, with 17.50 in between the mounting slots on the drawing and a shipping weight of 3.5 lbs (1.59 kg). Front and back are ASA 61 grey painted steel, a powder coat finish that complies with the Greenguard guidelines for indoor air quality.
All six outlets face forward with no rear receptacles and no rotated spacing, giving standard 5-15R spacing across the 1U panel. The unit is rated 125 VAC, 60 Hz, 15 Amps on the drawing and listed at 120 VAC / 15 A on the part data. 1582T6D1 is UL Recognized to UL1363 and CSA Certified to C22.2 (No. 21-95, 42-99) under UL file E166039, is RoHS, REACH and USMCA compliant, TAA-compliant for federal GSA schedule purchases within the USA, and is manufactured in North America.
Ideal For
- Front-of-rack power distribution in 19" server and network cabinets
- Powering AV and broadcast gear in open-frame relay racks
- Facility and OEM equipment racks needing a secure L5-15P locking source connection
- TAA-compliant federal GSA schedule rack builds
- Industrial or control racks requiring a 15 A branch with built-in circuit breaker
Overview
| Series | 1582 Series Rack Mount Basic PDU |
| Metered | No |
| Part Number | 1582T6D1 |
| Switch Type | No Switch. Power Indicator Light |
| Hospital Grade | No |
| Surge Protection | No |
| Outlet Strip Type | 1U 19in Rack Mount |
| Short Description | 19" RACK MOUNT, 6 REC ON FRONT |
Dimensions
| Depth | 2.66 in (68 mm) / 67.58 mm [2.661 in] |
| Width | 19.00 in (483 mm) / 482.60 mm |
| Height | 1.72 in (44 mm) / 43.64 mm [1.718 in] |
| Corner Radius | R3.18 mm [0.125 in] |
| Section Detail | 127.00 mm [5.000 in] |
| Bottom Dimension (Drawing) | 461.98 mm [18.188 in] |
| Side Profile Depth (Drawing) | 40.46 mm [1.593 in] |
Electrical
| Indicator | Red power indicator light |
| Cord Length | 15 ft |
| Cord Included | Yes |
| Rated Current | 15 A |
| Rated Voltage | 120 VAC |
| Shielded Cord | No |
| Total Outlets | 6 |
| Outlets (Rear) | 0 |
| Outlets (Front) | 6 |
| Plug Blade Type | Locking |
| Rotated Outlets | No |
| Plug Type (NEMA) | L5-15P |
| Rating (Drawing) | 125 VAC, 60 Hz, 15 Amps |
| Cord Construction | Heavy-duty 14 gauge, 14/3 SJT type for extreme temperature ranges, integral moulded plug |
| Outlet Type (NEMA) | 5-15R |
| Overcurrent Protection | 15 Amp, 125 VAC resettable circuit breaker |
| Phase / Voltage (Series) | Single-Phase 125V |
Identifiers
| UPC | 623980998022 |
| UNSPSC | 39121710 |
| GTIN-14 | 00623980998022 |
| UPC W/o Check Digit | 62398099802 |
Rack Mounting
| Rack Units | 1U horizontal |
| Rack Width | 19" EIA rack |
| Mounting Orientation | Front-facing power distribution |
Packaging & Shipping
| Tariff Code | 8537.10.9170 |
| Manufacturing | Manufactured in North America |
| Shipping Weight | 3.5 lbs (1.59 kg) |
| Country Of Origin | CA |
Construction & Finish
| Color | Gray |
| Material | Painted steel |
| Finish Type | ASA61 gray powder coat |
| Finish - Back | ASA 61 Grey Painted Steel |
| Finish - Front | ASA 61 Grey Painted Steel |
Environmental & Protection
| Indoor Air Quality | Complies with Greenguard guidelines for indoor air quality |
Compliance & Certifications
| UL | UL Recognized Standard UL1363 |
| CSA | CSA Certified Standards C22.2 (No. 21-95, 42-99) |
| ECCN | EAR99 |
| Standards | cRUus, TAA-compliant |
| UL File # | E166039 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| USMCA Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Does the 1582T6D1 have an on/off switch?▾
No. This version has no switch; it uses an illuminated red power indicator light. The equivalent model with an illuminated on/off rocker switch in the same configuration is 1582H6D1.
What plug is on the cord and how long is it?▾
The 1582T6D1 ships with a 15 ft heavy-duty 14 gauge 14/3 SJT cord with an integral moulded NEMA L5-15P locking plug.
How many outlets are there and where do they face?▾
Six NEMA 5-15R outlets, all on the front of the unit, with no rear outlets. The outlets are not rotated on this model.
Is the unit surge protected or metered?▾
No. The 1582T6D1 has no surge protection and no local amp meter. It does include a 15 Amp, 125 VAC resettable circuit breaker to prevent accidental overload.
How much rack space does it take and what are the dimensions?▾
It is a 1U horizontal 19" rackmount panel measuring 1.72 in (44 mm) high x 19.00 in (483 mm) wide x 2.66 in (68 mm) deep, weighing 3.5 lbs (1.59 kg) shipping weight.
What approvals does this PDU carry?▾
It is UL Recognized to Standard UL1363 and CSA Certified to Standards C22.2 No. 21-95 and No. 42-99 under UL file E166039, and it is RoHS, REACH and USMCA compliant plus TAA-compliant for federal GSA schedule purchases within the USA.
Related Products
Save 35%1582T6C1BKRA — 90 Deg 6 Outlet Light 6' Tw
Hammond Manufacturing · 1582T6C1BKRA
Save 35%1582T6D1BKRA — 90 Deg 6 Outlet Light 15' Tw
Hammond Manufacturing · 1582T6D1BKRA
Save 35%1582T6C1BK — 15A 6 Outlet Strip, 6 ft. cord - T Lock - Outlets Front - Black
Hammond Manufacturing · 1582T6C1BK
Save 35%1582T6D1SBK — 19" Rm Surge, 6 Recep Front BK
Hammond Manufacturing · 1582T6D1SBK
Save 35%1582T6C1 — 19" Rack Mount, 6 Rec On Front
Hammond Manufacturing · 1582T6C1