Hammond UHDM844118MFTC 84x40.75x18 Main Single-Door Type 12 Enclosure
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Main enclosure, left side open, single door: 84.13 x 40.75 x 18.13 in (2137 x 1035 x 461 mm)
- Includes 72.00 x 33.75 in formed 10 gauge steel inner panel, white powder coated
- UL 508A Type 12, CSA Type 12; complies with NEMA Type 12 and IEC 60529 IP54
- 10 gauge steel with continuously welded seams, ANSI 61 gray powder coat
- Flange trough collar around the door excludes liquids and contaminants
- Universal flange cutout for ABB, Allen Bradley, C-H, GE, I-T-E and Square D operators
- Three point latching, padlock hasp and main-door interlock on the auxiliary door
- Drawing: 17.28 in usable depth, door opening 34.75 x 73.38 in
The UHDM844118MFTC is the main enclosure of a Type 12 mild steel modular freestanding disconnect system: the section that houses the flange-mounted disconnect switch or circuit breaker operator, with its left side open so secondary enclosures can be bolted on. It measures 84.13 x 40.75 x 18.13 in (2137 x 1035 x 461 mm), has a single-door front and ships with a 72.00 x 33.75 in inner panel. It is aimed at panel builders, OEM engineers and electrical contractors assembling multi-section disconnect line-ups.
The 84.13 in height raises the inner panel to 72.00 in while keeping the 18.13 in depth, giving more vertical mounting space than the 72 in main enclosures. The drawing shows a door opening of 34.75 x 73.38 in and 17.28 in of usable depth.
The body is formed from 10 gauge steel with smooth continuously welded seams, heavy duty lifting eyes in reinforced top corners and removable doors on heavy duty lift off hinges. A flange trough collar (FTC) around the door excludes liquids and contaminants, the reinforced side openings give smooth edges and preset gasket compression, and oil resistant gaskets are permanently secured. The formed 10 gauge inner panel sits on collar studs with panel supports and a removable center post. The enclosure is phosphatized and finished in recoatable smooth ANSI 61 gray powder coat; the inner panel is white.
A heavy duty three point latching mechanism secures the door. The main door handle has a screw defeater and padlock hasp, and a mechanical interlock activated by the main door prevents the auxiliary door from being opened first. The universal flange cutout accepts ABB, Allen Bradley 1494V/1494U, C-H Westinghouse C361, Cutler Hammer C371, GE STDA, I-T-E Max-Flex and Square D Class 9422 flange mechanisms using the appropriate operator adaptor kit. Disconnects and operators are not included.
The UHDM system is listed to UL 508A Type 12 and CSA Type 12 and complies with NEMA Type 12 and IEC 60529 IP54; appropriate components are required to maintain these standards.
Ideal For
- Multi-section freestanding disconnect line-ups
- Industrial control panels in Type 12 (NEMA 12) indoor environments
- Housing flange mounted disconnect switches and circuit breaker operators
- Control panel line-ups requiring IP54 protection
Overview
| Series | UHD M Series (UHDM) |
| Door Type | Single |
| Door Style | Hinge door with handle (flange with multi-vendor cutout) |
| Not Included | Disconnect switches, circuit breakers and operators (order separately) |
| Product Type | Type 12 mild steel modular freestanding disconnect enclosure with inner panel |
| Side Openings | Left side open |
| Enclosure Role | Main enclosure |
| Material / Color | Steel / Gray |
| Available Accessories (Sold Separately) | Flange disconnect operator adaptor kits, door stop kit, floor stand kit, window kits, climate control, lighting, general accessories |
Dimensions
| Door Width | 36.50 in (drawing) |
| Door Height | 75.13 in (drawing) |
| Door Opening | 34.75 in W x 73.38 in H (drawing) |
| Usable Depth | 17.28 in (drawing) |
| Enclosure Depth | 18.13 in (461 mm) |
| Enclosure Width | 40.75 in (1035 mm) |
| Enclosure Height | 84.13 in (2137 mm) |
| Size (H X W X D) | 84.13 in x 40.75 in x 18.13 in (2,137 mm x 1,035 mm x 461 mm) |
| Inner Panel Width | 33.75 in (857 mm) |
| Inner Panel Height | 72.00 in (1829 mm) |
| Side Opening Cutout | 13.13 in x 78.88 in (drawing) |
| Clear Space Available On Door | 30.71 in (drawing) |
Identifiers
| UPC | 623980199429 |
| UNSPSC | 39121324 |
| Part Number | UHDM844118MFTC |
| Drawing Date | Sep. 27, 2024 |
| Long Description | N12 Modular Disconnect Enc w/panel - 84.13 x 40.75 x 18.13 - Steel/Gray |
| Short Description | SINGLE DOOR MODULAR DISCONNECT |
Packaging & Shipping
| Packaging Type | Skid |
| Shipping Weight | 600 lbs (272.16 kg) |
Construction & Finish
| Hinges | Removable doors on heavy duty lift off hinges |
| Gaskets | Oil resistant, permanently secured on doors and side openings; no gasket kit provided |
| Lifting | Heavy duty lifting eyes anchored into reinforced top corners |
| Latching | Heavy duty three point latching door mechanism |
| Stiffeners | Body stiffeners provided in the larger enclosures for extra rigidity |
| Center Post | Removable, for easy panel installation |
| Door Collar | Flange trough collar (FTC) around door excludes liquids and contaminants |
| Inner Panel | Formed 10 gauge steel, mounted on collar studs; panel supports provided |
| Body Material | 10 gauge steel, smooth continuously welded seams |
| Flange Cutout | Universal flange cutout; mounts disconnect operators with the appropriate operator adaptor kit |
| Side Openings | Reinforced for structural strength, smooth edges and preset gasket compression |
| Door Interlock | Mechanical interlock activated by the main door prevents the auxiliary door from being opened first |
| Enclosure Finish | Phosphatized, recoatable smooth ANSI 61 gray powder coating |
| Main Door Handle | Screw defeater and padlock hasp |
| Literature Pocket | Provided |
| Inner Panel Finish | White powder coating |
| Bonding / Grounding | Bonding stud in the door and grounding stud in the enclosure for each door |
| Secondary Door Handle | Padlock hasp |
Disconnect Compatibility
| I-T-E | Max-Flex flange mounted variable depth operating handles |
| Square D | Class 9422 flange mounted variable depth operating mechanisms or cable mechanisms |
| ABB Controls | Flange mounted variable depth operating mechanism for disconnect switches and circuit breakers |
| Not Accepted | Square D Class 9422 bracket mounted disconnect devices; Class 9422TG1 or TG2 devices |
| Allen Bradley | 1494V and 1494U variable depth flange mounted disconnect switches and circuit breaker mechanisms |
| General Electric | Type STDA flange handles and variable depth operating mechanisms; Spectra-Flex cable operators for circuit breakers |
| C-H Westinghouse / Cutler Hammer | Type C361 disconnect switches and operator mechanism; Type C371 circuit breaker operating mechanisms; Flex Shaft handle operators for circuit breakers |
Compliance & Certifications
| UL | UL 508A Type 12 |
| CSA | CSA Type 12 |
| IEC | Complies with IEC 60529, IP54 |
| NEMA | Complies with NEMA Type 12 |
| RoHS Compliant | Yes |
| Standards Note | Appropriate components are required to maintain these standards |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Is the UHDM844118MFTC a main or secondary enclosure?▾
It is a main enclosure with the left side open. It houses the flange mounted disconnect switch or circuit breaker operator, and secondary enclosures can be added beside it.
What are its dimensions?▾
The enclosure is 84.13 in high, 40.75 in wide and 18.13 in deep (2137 x 1035 x 461 mm). The inner panel is 72.00 x 33.75 in, and the drawing shows 17.28 in of usable depth.
Does it include a disconnect switch or breaker?▾
No. Disconnect switches, circuit breakers and operators are not provided with the enclosure and must be ordered separately from the manufacturer.
What ratings does it carry?▾
The UHDM series is UL 508A Type 12 and CSA Type 12 and complies with NEMA Type 12 and IEC 60529 IP54. Appropriate components are required to maintain these standards.
Is a gasket kit needed?▾
Oil resistant gaskets on the doors and side openings are permanently secured, and no gasket kit is provided.
How much does it weigh to ship?▾
The shipping weight is 600 lbs (272.16 kg), and it ships on a skid.
Related Products
Save 33%UHDM8424EPA — Flat End Plate - 84 x 24 - Steel/Gray
Hammond Manufacturing · UHDM8424EPA
Save 33%UHDM844118SFTC — N12 Modular Disconnect Enc w/panel - 84.13 x 40.75 x 18.13 - Steel/Gray
Hammond Manufacturing · UHDM844118SFTC
Save 33%UHDM8424ECA — Formed End Cap - 84 x 24 - Steel/Gray
Hammond Manufacturing · UHDM8424ECA
Save 33%UHDM844124MFTC — N12 Modular Disconnect Enc w/panel - 84.13 x 40.75 x 24.13 - Steel/Gray
Hammond Manufacturing · UHDM844124MFTC
Save 33%UHDM8424BPA — Flat Barrier Plate - 84 x 24 - Steel/Gray
Hammond Manufacturing · UHDM8424BPA