Hammond PWS3302A230N4LG 12283 BTU/h Air/Water Heat Exchanger, 230V Light Gray
Ships from and sold by A5 IT
Available on backorder — ships as soon as stock arrives
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Cooling capacity 12283 BTU/h (3600 W) at +95 F enclosure / +50 F water
- 230 V, 50/60 Hz; 59.0 W power consumption, 0.31 A running current
- Air volume 315 CFM (535 m3/h); coolant flow 2 GPM (450 L/h) at rated capacity
- Adjustable control range +46 to +122 F (+8 to +50 C), factory set at +95 F (+35 C)
- Galvanized steel case in RAL7035 Light Gray; NEMA/Type 3R/4 per part description
- Rugged (10 bar) copper tube / aluminum fin core with 1/2 in barb connection
- Integrated thermostat and solenoid valve with alarm contact
- Unit size 51.89 in H x 15.76 in W x 9.07 in D; side, door or internal mounting
The PWS3302A230N4LG is a full-height air/water heat exchanger from the PWS 3000 Series: the highest-capacity model of the 7000-12000 BTU/H PWS 3000 range, sharing the 51.89 in housing of the PWS 3202 while delivering 12283 BTU/h. Panel builders and OEM designers use it to cool enclosures with chilled water/glycol, tower water or other circulated coolants where ambient conditions are hot, harsh or subject to frequent wash-down.
The PWS 3302 is rated at 12283 BTU/h (3600 W) at +95 F (+35 C) enclosure and +50 F (+10 C) water; it moves 315 CFM (535 m3/h) of enclosure air on 2 GPM (450 L/h) of coolant at rated capacity. This is the 230 V version, specified for 50/60 Hz supply; it consumes 59.0 W and draws 0.31 A running current, with a terminal block power connection. An integrated thermostat and solenoid valve with alarm contact provide automatic temperature control.
The exterior case is galvanized steel finished in RAL7035 Light Gray, and the part description rates this variant NEMA/Type 3R/4. Inside, a rugged (10 bar) copper tube / aluminum fin heat exchanger connects through a 1/2 in barb. The series ordering table gives the unit as 51.89 in (1318 mm) high, 15.76 in (400 mm) wide and 9.07 in (230 mm) deep, while the part page lists a size of 53.89 in x 16.76 in x 10.07 in (1,369 mm x 426 mm x 256 mm). Shipping weight is 70 lbs (31.75 kg). The series is rated UL, cUL and CE.
Its control range adjusts from +46 to +122 F (+8 to +50 C), factory set at +95 F (+35 C), and the unit is specified for ambient air from +36 to +158 F (+2 to +65 C). Side, door or internal mounting gives installation flexibility, and the low noise design is maintenance-free. The manual requires coolant at least 10 C colder than the inlet air.
Ideal For
- High heat-load enclosures on a chilled water/glycol loop
- Tower-water cooling of panels in very hot ambient air
- Harsh-condition installations
- Frequent wash-down areas
Quality
| Leak Testing | All devices are checked for leaks before leaving the factory |
Overview
| Model | PWS 3302 |
| Series | PWS 3000 Series (7000-12000 BTU/H) |
| Product Type | Air/Water Heat Exchanger |
| Long Description | Air/Water Heat Exch. 3600W 230V 3R/4 LG |
| Short Description | AW HX 3600W-3R/4-LT.GRAY |
Dimensions
| Depth (Series Table) | 9.07 in (230 mm) |
| Width (Series Table) | 15.76 in (400 mm) |
| Height (Series Table) | 51.89 in (1318 mm) |
| Listed Size H X W X D (Part Page) | 53.89 in x 16.76 in x 10.07 in (1,369 mm x 426 mm x 256 mm) |
Electrical
| Frequency | 50/60 Hz |
| Running Amps | 0.31 A |
| Rated Voltage | 230 V |
| Power Connection | Terminal Block (hard wired terminal) |
| Power Consumption | 59.0 W |
Accessories
| Available Accessories | Remote door switches, gasket kits, condensate bottle |
Connections
| Heat Exchanger Connection | 1/2 in barb connection |
Identifiers
| UPC | 623980336381 |
| UNSPSC | 39121301 |
| Part Number | PWS3302A230N4LG |
Installation
| Door Contact | Door contact switch recommended to turn the unit off when the enclosure door is opened |
| Mounting Style | Bolt-on unit for door or side mounting on electrical panel enclosures |
| Mounting Options | Side, door or internal mounting |
| Cooling Water Hose | Flexible pressure-resistant (>10 bar) hose secured with clamps |
| Supply Voltage Tolerance | Within ± 10% of the ID plate value |
| Supply Frequency Tolerance | Within ± 3 Hz of the ID plate value |
| Insulation Strip Compression | 2 mm (approx. 0.080 in) |
| Coolant Temperature Requirement | Cooling liquid must be at least 10 C colder than the heat exchanger inlet air temperature |
| Maximum Permissible Operating Pressure | 10 bar |
Cooling Performance
| Air Volume | 315 CFM (535 m3/h) |
| Factory Setting | +95 F (+35 C) |
| Operating Pressure | 14.5 - 145 PSI (1 - 10 bar) |
| Compatible Coolants | Chilled water/glycol, tower water and other circulated coolants |
| Temperature Control | Integrated thermostat and solenoid valve with alarm contact for automatic temperature control |
| Adjustable Control Range | +46 to +122 F (+8 to +50 C) |
| Flow Rate At Rated Capacity | 2 GPM (450 L/h) |
| Cooling Capacity (Enclosure +95 F / +35 C, Water +50 F / +10 C) | 12283 BTU/h (3600 W) |
Packaging & Shipping
| Included Items | Cooling unit, mounting cutout, manual, technical data sheet |
| Shipping Weight | 70 lbs (31.75 kg) |
| Accessory Pack (Typical) | Sealing strips, threaded mounting studs, mounting bolts, nuts and washers, condensate hose, door contact connector/jumper |
Construction & Finish
| Design | Low noise, maintenance-free |
| Finish | RAL7035 Light Gray |
| Exterior Case | Galvanized steel |
| Heat Exchanger Core | Rugged (10 bar) copper tube / aluminum fin |
Environmental & Protection
| Freezing Conditions | Water circuit must be completely emptied with compressed air before storage or transport below freezing |
| Ambient Air Temperature | +36 to +158 F (+2 to +65 C) |
| Storage Temperature Limit | Must not be exposed to temperatures exceeding +70 C |
Compliance & Certifications
| Standards | UL, cUL, and CE |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Series Enclosure Ratings | NEMA 3R, 4, 4X |
| Enclosure Rating (Part Description) | NEMA/Type 3R/4 |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What is the cooling capacity of the PWS3302A230N4LG?▾
The series specification sheet rates the PWS 3302 at 12283 BTU/h (3600 W) with the enclosure at +95 F (+35 C) and the water at +50 F (+10 C).
What power supply does it need?▾
This variant is rated 230 V at 50/60 Hz, consumes 59.0 W and draws 0.31 A running current. Power connects through a terminal block. Supply voltage must be within ± 10% and frequency within ± 3 Hz of the ID plate values.
What coolants and water conditions does it accept?▾
It is compatible with chilled water/glycol, tower water and other circulated coolants. Rated capacity needs 2 GPM (450 L/h), operating pressure is 14.5 - 145 PSI (1 - 10 bar), and the coolant must be at least 10 C colder than the heat exchanger inlet air.
How is it mounted?▾
The series supports side, door or internal mounting. The manual describes bolting the unit to the enclosure with the supplied stud bolts, screws and washers, compressing the insulation strips to 2 mm (approx. 0.080 in).
What finish and enclosure rating does the PWS3302A230N4LG have?▾
The exterior case is galvanized steel finished in RAL7035 Light Gray, and the part description rates it NEMA/Type 3R/4. The series lists UL, cUL and CE.
What accessories are available?▾
The series specification sheet lists remote door switches, gasket kits and a condensate bottle as accessories. A door contact switch is recommended to turn the unit off when the enclosure door is opened.
Related Products
Save 31%PWS3302A115N4SS — Air/Water Heat Exch. 3600W 115V 4/4X SS
Hammond Manufacturing · PWS3302A115N4SS
Save 31%PWS3302A230N4SS — Air/Water Heat Exch. 3600W 230V 4/4X SS
Hammond Manufacturing · PWS3302A230N4SS
Save 31%PWS3302A115N4LG — Air/Water Heat Exch. 3600W 115V 3R/4 LG
Hammond Manufacturing · PWS3302A115N4LG
Save 31%PWS3202A230N4SS — Air/Water Heat Exch. 2100W 230V 4/4X SS
Hammond Manufacturing · PWS3202A230N4SS
Save 31%PWS3202A230N4LG — Air/Water Heat Exch. 2100W 230V 3R/4 LG
Hammond Manufacturing · PWS3202A230N4LG