(224) 955-1644
Hammond ManufacturingAuthorized partner store
PKS3363A115N4LG Type 3R/4 air to air heat exchanger, 180 W/°C, 115V, with light gray powder coated steel cover

Hammond PKS3363A115N4LG 180 W/°C 115V Type 3R/4 Air-to-Air Heat Exchanger

Hammond Manufacturing|

MPN: PKS3363A115N4LG

|

UPC: 623980274171

Available on Backorder
$4,888.25

Ships from and sold by A5 IT

Available on backorder — ships as soon as stock arrives

Ground Shipping · $140.99Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 180 W/°C (100 W/°F) cooling capacity; 3600W (12200 BTU) sample performance at ΔT 20°C/36°F
  • Powered from 115V, 60 Hz
  • Maintains enclosure NEMA 3R/4 rating; IP 56; UR, cUR and CE
  • Closed loop design: enclosure air never mixes with contaminated ambient air
  • Light Gray (RAL7035) powder coated steel cover
  • Thermostat control accessible inside the enclosure; door contact provision powers down when door opens
  • Mounts vertically or horizontally; gasket, mounting kit and cutout/drilling template included
  • 35.30 in (897 mm) H x 11.97 in (304 mm) W x 16.04 in (407 mm) D; 65 lbs (29.48 kg) shipping weight

The PKS3363A115N4LG is a Type 3R/4 closed loop air to air heat exchanger from the PKS4 Series, rated 180 W/°C (100 W/°F) and powered from a 115V 60 Hz supply. It is the highest capacity in the series, designed for outdoor applications and suited to outdoor switch cabinets that must keep their NEMA 3R/4 rating.

An air to air heat exchanger is a fit when the surrounding air is at least 10°C/18°F cooler than the target internal temperature. Clean enclosure air is recirculated in a closed loop and never mixes with contaminated ambient air, and the series is described as more energy efficient with lower maintenance costs than air conditioners. At a 20°C/36°F difference between ambient and target internal temperature, the PKS3363A115N4LG shows a sample performance of 3600W (12200 BTU); actual cooling depends on that ΔT.

The ordering table gives 35.30 in (897 mm) high, 11.97 in (304 mm) wide and 16.04 in (407 mm) deep including louvers, which extend 1.5 in on either side (nominal size 35 in x 12 in x 16 in (889 mm x 305 mm x 406 mm)). Shipping weight is 65 lbs (29.48 kg). The cover is finished in Light Gray (RAL7035) powder coated steel. The unit maintains the enclosure's NEMA 3R/4 rating, is rated IP 56 and carries UR, cUR and CE marks, uses R134a refrigerant, and its EMI/RFI suppression meets CE.

For installation, a gasket, mounting kit and template for the cutout and drilling are included, and the unit can be mounted vertically or horizontally. The thermostat control is accessible from inside the enclosure, and a door contact provision powers the unit down when the enclosure door is opened. Remote door switches and gasket kits are available as accessories.

Ideal For

  • Cooling outdoor NEMA 3R/4 enclosures
  • Closed loop cooling where ambient air is contaminated
  • Energy-efficient alternative to enclosure air conditioners
  • Outdoor cabinets with ambient at least 10°C/18°F below target

Overview

SeriesPKS4 Series (Air to Air Heat Exchangers - Type 3R/4)
Designed ForOutdoor applications
Product TypeAir to Air Heat Exchanger
Cooling PrincipleClosed loop; clean enclosure air is recirculated without mixing with contaminated ambient air
Short DescriptionAA HX 180W/C 115V N4 LT GRAY
Application ConditionSurrounding air temperature lower than target internal temperature by at least 10°C/18°F

Dimensions

Depth16.04 in (407 mm)
Width11.97 in (304 mm)
Height35.30 in (897 mm)
LouversExtend 1.5 in on either side
Nominal Size (H X W X D)35 in x 12 in x 16 in (889 mm x 305 mm x 406 mm)
Overall Dimensions (Drawing)897 mm (35.31 in) H x 304 mm (11.97 in) W x 407 mm (16.04 in) D
Additional Drawing Depth Dimensions370 mm (14.57 in); 271 mm (10.65 in)

Electrical

Door ContactProvision for power down when enclosure door is opened
EMI/RFI SuppressionMeets CE
Temperature ControlThermostat control accessible from inside enclosure
Voltage - Frequency115V 60 Hz
Controller Set PointsUnit set point control (1TAS) and alarm set point control (2TAS)

Identifiers

UPC623980274171
UNSPSC39121301
Part NumberPKS3363A115N4LG

Performance

RefrigerantR134a
Performance NoteActual cooling performance based on difference (ΔT) between ambient and target internal temperature
Cooling Capacity (W/°C)180 W/°C
Cooling Capacity (W/°F)100 W/°F
Sample Performance At ΔT = 20°C/36°F3600W (12200 BTU)

Installation

IncludedGasket, mounting kit and template for cutout and drilling
OperationStationary operation only
Scope Of DeliveryCooling unit, quick guide, accessory kit (seal, fastening material, electrical plug connector, etc.), special accessories if applicable
Mounting OrientationVertical or horizontal
Available AccessoriesRemote Door Switches; Gasket Kits
Drilling Template Mounting Holes14 x 8 mm (0.31 in)

Packaging & Shipping

Shipping Weight65 lbs (29.48 kg)

Construction & Finish

CoverLight Gray (RAL7035) powder coated steel

Environmental & Protection

Ingress ProtectionIP 56
Enclosure Rating MaintainedNEMA 3R/4

Compliance & Certifications

ApprovalsUR, cUR and CE
RoHS CompliantYes
REACH CompliantYes
Material DeclarationFree from silicone connections; PCT, asbestos, formaldehyde, cadmium; moisture-impairing substances

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

How much heat can the PKS3363A115N4LG remove?▾

It is rated 180 W/°C (100 W/°F). As a sample, at a 20°C/36°F difference between ambient and target internal temperature it delivers 3600W (12200 BTU). Actual performance depends on that temperature difference.

What power supply does the PKS3363A115N4LG need?▾

The ordering table lists 115V 60 Hz for this part number. Other voltages are offered as separate part numbers in the PKS4 Series.

When is an air to air heat exchanger the right choice?▾

When the surrounding air temperature is lower than the target internal temperature by at least 10°C/18°F. The closed loop recirculates clean enclosure air without mixing it with contaminated ambient air.

Will it keep my enclosure's NEMA 3R/4 rating?▾

Yes. The PKS4 Series maintains the enclosure's NEMA 3R/4 rating, is rated IP 56 and carries UR, cUR and CE marks.

What comes in the box for installation?▾

A gasket, mounting kit and template for the cutout and drilling are included, along with a quick guide and an accessory kit with the seal, fastening material and electrical plug connector.

Can it be mounted horizontally?▾

Yes, it can be mounted vertically or horizontally. The unit measures 35.30 in (897 mm) H x 11.97 in (304 mm) W x 16.04 in (407 mm) D, with louvers extending 1.5 in on either side.