Hammond PKS3361A230LG 180 W/°C 230V Type 12 Indoor Air-to-Air Heat Exchanger
Ships from and sold by A5 IT
Available on backorder — ships as soon as stock arrives
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 180 W/°C (100 W/°F) cooling capacity; 3600W (12200 BTU) sample performance at ΔT 20°C/36°F
- Powered from 230V, 50/60 Hz
- Maintains enclosure NEMA 12 rating; IP 54; UR, cUR and CE
- Closed loop design: enclosure air never mixes with contaminated ambient air
- Light Gray (RAL7035) powder coated steel cover
- Thermostat control accessible inside the enclosure; door contact provision powers down when door opens
- Mounts vertically or horizontally; gasket, mounting kit and cutout/drilling template included
- 35.31 in (897 mm) H x 11.97 in (304 mm) W x 10.65 in (271 mm) D; 65 lbs (29.48 kg) shipping weight
The PKS3361A230LG is a Type 12 closed loop air to air heat exchanger from the PKS12 Series, rated 180 W/°C (100 W/°F) and powered from a 230V supply at 50 or 60 Hz. It is the highest capacity in the series, designed for indoor applications and suited to dissipating heat from indoor switch cabinets.
An air to air heat exchanger is a fit when the surrounding air is at least 10°C/18°F cooler than the target internal temperature. Clean enclosure air is recirculated in a closed loop and never mixes with contaminated ambient air, and the series is described as more energy efficient with lower maintenance costs than air conditioners. At a 20°C/36°F difference between ambient and target internal temperature, the PKS3361A230LG shows a sample performance of 3600W (12200 BTU); actual cooling depends on that ΔT.
The ordering table gives 35.31 in (897 mm) high, 11.97 in (304 mm) wide and 10.65 in (271 mm) deep (nominal size 35 in x 12 in x 11 in (889 mm x 305 mm x 279 mm)). Shipping weight is 65 lbs (29.48 kg). The cover is finished in Light Gray (RAL7035) powder coated steel. The unit maintains the enclosure's NEMA 12 rating, is rated IP 54 and carries UR, cUR and CE marks, uses R134a refrigerant, and its EMI/RFI suppression meets CE.
For installation, a gasket, mounting kit and template for the cutout and drilling are included, and the unit can be mounted vertically or horizontally. The thermostat control is accessible from inside the enclosure, and a door contact provision powers the unit down when the enclosure door is opened. Remote door switches and gasket kits are available as accessories.
Ideal For
- Cooling indoor NEMA 12 control enclosures
- Closed loop cooling where ambient air is contaminated
- Energy-efficient alternative to enclosure air conditioners
- Electrical cabinets with ambient at least 10°C/18°F below target
Overview
| Series | PKS12 Series (Air to Air Heat Exchangers - Type 12) |
| Designed For | Indoor applications |
| Product Type | Air to Air Heat Exchanger |
| Cooling Principle | Closed loop; clean enclosure air is recirculated without mixing with contaminated ambient air |
| Short Description | AA HX 180W/C 230V N12 LT GRAY |
| Application Condition | Surrounding air temperature lower than target internal temperature by at least 10°C/18°F |
Dimensions
| Depth | 10.65 in (271 mm) |
| Width | 11.97 in (304 mm) |
| Height | 35.31 in (897 mm) |
| Nominal Size (H X W X D) | 35 in x 12 in x 11 in (889 mm x 305 mm x 279 mm) |
| Overall Dimensions (Drawing) | 897 mm (35.31 in) H x 304 mm (11.97 in) W x 271 mm (10.65 in) D |
Electrical
| Door Contact | Provision for power down when enclosure door is opened |
| EMI/RFI Suppression | Meets CE |
| Temperature Control | Thermostat control accessible from inside enclosure |
| Voltage - Frequency | 230V 50/60 Hz |
| Controller Set Points | Unit set point control (1TAS) and alarm set point control (2TAS) |
Identifiers
| UPC | 623980274157 |
| UNSPSC | 39121301 |
| Part Number | PKS3361A230LG |
Performance
| Refrigerant | R134a |
| Performance Note | Actual cooling performance based on difference (ΔT) between ambient and target internal temperature |
| Cooling Capacity (W/°C) | 180 W/°C |
| Cooling Capacity (W/°F) | 100 W/°F |
| Sample Performance At ΔT = 20°C/36°F | 3600W (12200 BTU) |
Installation
| Included | Gasket, mounting kit and template for cutout and drilling |
| Operation | Stationary operation only |
| Scope Of Delivery | Cooling unit, quick guide, accessory kit (seal, fastening material, electrical plug connector, etc.), special accessories if applicable |
| Mounting Orientation | Vertical or horizontal |
| Available Accessories | Remote Door Switches; Gasket Kits |
| Drilling Template Mounting Holes | 14 x 8 mm (0.31 in) |
Packaging & Shipping
| Shipping Weight | 65 lbs (29.48 kg) |
Construction & Finish
| Cover | Light Gray (RAL7035) powder coated steel |
Environmental & Protection
| IP 54 Note | Essentially dust-protected (dust can still penetrate after continuous exposure); resistant to spray water, not a constant water jet |
| Ingress Protection | IP 54 |
| Enclosure Rating Maintained | NEMA 12 |
Compliance & Certifications
| Approvals | UR, cUR and CE |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Material Declaration | Free from silicone connections; PCT, asbestos, formaldehyde, cadmium; moisture-impairing substances |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
How much heat can the PKS3361A230LG remove?▾
It is rated 180 W/°C (100 W/°F). As a sample, at a 20°C/36°F difference between ambient and target internal temperature it delivers 3600W (12200 BTU). Actual performance depends on that temperature difference.
What power supply does the PKS3361A230LG need?▾
The ordering table lists 230V 50/60 Hz for this part number. Other voltages are offered as separate part numbers in the PKS12 Series.
When is an air to air heat exchanger the right choice?▾
When the surrounding air temperature is lower than the target internal temperature by at least 10°C/18°F. The closed loop recirculates clean enclosure air without mixing it with contaminated ambient air.
Will it keep my enclosure's NEMA 12 rating?▾
Yes. The PKS12 Series maintains the enclosure's NEMA 12 rating, is rated IP 54 and carries UR, cUR and CE marks.
What comes in the box for installation?▾
A gasket, mounting kit and template for the cutout and drilling are included, along with a quick guide and an accessory kit with the seal, fastening material and electrical plug connector.
Can it be mounted horizontally?▾
Yes, it can be mounted vertically or horizontally. The unit measures 35.31 in (897 mm) H x 11.97 in (304 mm) W x 10.65 in (271 mm) D.
Related Products
Save 31%PKS3361A115LG — Aa Hx 180W/C 115V N12 Lt Grey
Hammond Manufacturing · PKS3361A115LG
Save 31%PKS3361A460LG — Aa Hx 180W/C 460V N12 Lt Grey
Hammond Manufacturing · PKS3361A460LG
Save 31%PKS3301A460LG — Aa Hx 150W/C 460V N12 Lt Grey
Hammond Manufacturing · PKS3301A460LG
Save 31%PKS3301A230LG — Aa Hx 150W/C 230V N12 Lt Grey
Hammond Manufacturing · PKS3301A230LG
Save 31%PKS3301A115LG — Aa Hx 150W/C 115V N12 Lt Grey
Hammond Manufacturing · PKS3301A115LG