Hammond PF42500T12LG 94 CFM 115V AC Type 12 Filter Fan, Light Gray
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Hammond Manufacturing PF42500T12LG.
224-955-1644Key Features
- 94 CFM unimpeded airflow on 115V AC
- Pairs with PFA40000LG exhaust filter for 67 CFM in combination
- 252 x 252 x 97 mm (H x W x installation depth), 223 mm cutout
- UL-tested NEMA Type 12 seal; IP 55 (EN 60 529) when installed as specified
- Patented Click & Fit hardware-free installation
- UL Recognized to UL 508 (NITW2/8, File #E175229); CSA approved fan motor
- Ball bearings, cage clamp connection, 43 dB (A) noise level
- RAL 7035 Light Grey finish, REACH and RoHS compliant
The PF42500T12LG is a 94 CFM Type 12 filter fan (Filterfan) from the PF GEN4 Series (94-169 CFM Filterfans), in RAL 7035 Light Grey for 115V AC supplies. It is designed to draw filtered air into electrical and electronic enclosures to remove heat, while maintaining a UL-tested NEMA Type 12 seal against the enclosure.
For 115V AC panels, the installation manual rates the PF 42500 at 31 W and 0.27 A. Like the other AC versions it wires in on a cage clamp and runs on ball bearings.
Unimpeded airflow is 94 CFM, with a free-flow capacity of 53 W/K and a maximum static pressure of 49 Pa. Fitted with the PFA40000LG exhaust filter (PF 42500 + PFA 40000), airflow in combination is 67 CFM. Noise level is 43 dB (A) (EN ISO 3741), and the NEMA Type 12 filtermat is grade G 4 (DIN EN 779) with 0.91 filtration efficiency.
The fan measures 252 x 252 x 97 mm (height x width x installation depth) and weighs 1.18 kg. Its sprayed thermoplastic housing and guard are self-extinguishing to UL 94 V0, made from heat-resistant ABS-FR. The patented Click & Fit design installs without hardware in a 223 mm +1/-0 cutout for material up to 2 mm, or 224 mm +1/-0 for material over 2 mm and under 3 mm; any fitting position is allowed, horizontal airflow preferred.
The fan is UL Recognized to UL 508 (category NITW2/8, UL File #E175229) with a CSA approved motor, is rated NEMA Type 12, IP 55 (EN 60 529) when installed as specified, and is REACH and RoHS compliant.
Ideal For
- Cooling electrical control enclosures
- Ventilating NEMA Type 12 industrial panels
- Removing heat from electronic equipment enclosures
- 115V AC powered enclosure ventilation
Overview
| Model | PF 42500 |
| Colour | RAL 7035 Light Grey (Light Gray) |
| Series | PF GEN4 Series, 94-169 CFM Filterfans |
| Description | 94 CFM Filter Fan, 115V N12 - Lt. Gray |
| Product Type | Filter fan (Filterfan), Type 12 |
| Short Description | 94 CFM FILTER FAN T12 |
Dimensions
| Outside Dimensions (H X W X Installation Depth) | 252 x 252 x 97 mm |
Electrical
| Voltage | 115V AC |
| Connections | Cage clamp |
| Power (Installation Manual) | 31 W |
Accessories
| Basic Accessories | Parts kit filter mat, user manual |
| Available Accessories | Exhaust filters, replacement filters, Filterfan rainhoods 4/4X and 3R, thermostats |
| Exhaust Filter (Light Gray / Black) | PFA40000LG / PFA40000BK |
Identifiers
| UPC | 623980016061 |
| UNSPSC | 39121302 |
| Part Number | PF42500T12LG |
Packaging & Shipping
| Shipping Weight | 3.35 lbs (1.52 kg) |
Airflow & Performance
| Duty Cycle | 1 |
| Filter Material | NEMA Type 12 Filtermat |
| Unimpeded Airflow | 94 CFM |
| Capacity Free-Flow | 53 W/K |
| Filter Material Grade | G 4 (DIN EN 779) |
| Filtration Efficiency | 0.91 |
| Noise Level (EN ISO 3741) | 43 dB (A) |
| Max. Static Pressure (Airflow = 0 M3/h) | 49 Pa |
| Airflow In Combination (PF 42500 + PFA 40000) | 67 CFM |
| Capacity In Combination (As Printed On Spec Sheet) | 38 W/K |
Construction & Finish
| Unit Weight | 1.18 kg |
| Bearing Type | Ball bearings |
| Construction | Housing and guard of sprayed thermoplastic, self-extinguishing, UL 94 V0 |
| Installation | Patented Click & Fit design, hardware-free installation |
| Fitting Position | Any, horizontal airflow preferred |
| Plastic Material | Heat resistant ABS-FR, UL 94 V0 fire approved |
| Safety Protection | In accordance with DIN 31 001 |
Environmental & Protection
| Storage Temperature | -20 °C (-4 °F) to +70 °C (+158 °F) |
| System Of Protection | NEMA Type 12, IP 55 (EN 60 529), when installed as specified |
| Operating Temperature | -15 °C (-5 °F) to +55 °C (+131 °F) |
| Installation Condition | Type 12 protection only with vertical installation position and non-destroyed foam gasket |
| Max. Relative Humidity | 0.9 |
Compliance & Certifications
| UL | UL Recognized to UL 508, category NITW2/8, UL File #E175229 |
| Fan Motor | CSA Approved |
| Enclosure Seal | UL Tested NEMA Type 12 seal against enclosure |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What is the airflow of the PF42500T12LG?▾
94 CFM unimpeded. Combined with the PFA 40000 exhaust filter, airflow is 67 CFM.
What size hole do I cut in the enclosure?▾
223 mm +1/-0 in material up to 2 mm thick, or 224 mm +1/-0 in material over 2 mm and under 3 mm. The fan's outside size is 252 x 252 mm.
Which exhaust filter goes with it?▾
The colour-matched exhaust filter is PFA40000LG; PFA40000BK is the black version.
What temperatures is it rated for?▾
Operating temperature is -15 °C (-5 °F) to +55 °C (+131 °F) and storage temperature is -20 °C (-4 °F) to +70 °C (+158 °F), with max. relative humidity 0.9.
Can the airflow be reversed?▾
Yes. For 4th generation PF 11000 to PF 43000 fans, remove the 4 screws on the back of the fan, flip it over and replace the screws hand-tight.
Related Products
010000018 — FAN-DTT6401
Hammond Manufacturing · 010000018
012000019 — Relay
Hammond Manufacturing · 012000019
012000020 — Compressor Start Cap
Hammond Manufacturing · 012000020
012000021 — Compressor Run Cap
Hammond Manufacturing · 012000021
012000055 — Capacitor
Hammond Manufacturing · 012000055