Hammond PCJ14126CCLF 14x12x6 Clear Cover Polycarbonate Box, Flange Mount
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Type 4X / IP66 polycarbonate junction box, 14x12x6 in nominal (356 mm x 305 mm x 152 mm)
- Clear injected polycarbonate cover over a light gray polycarbonate box
- Two stainless steel lockable snap latches with padlocking provision
- Four polycarbonate flanges (glued) for surface mounting
- Accepts optional PCJR1311 inner panel, 12.75 in (324 mm) x 10.88 in (276 mm), on brass inserts
- Closed cell neoprene gasket (captive, oil resistant) for a positive seal
- Operating temperature -35 °C to 130 °C (-31 °F to 266 °F); impact index 16 J (12 ft/lb)
The PCJ14126CCLF is a Type 4X polycarbonate junction box with a clear polycarbonate cover, sized at a 14 x 12 in face and 6 in nominal depth. It is built to insulate and protect controls and components indoors or outdoors, for pump controls, waste water, irrigation, solar/wind and chemical plants.
The box and cover are injection moulded polycarbonate thermoplastic that is easily punched, cut or drilled, with enhanced UV inhibitors against outdoor weathering (UV rating f1 per UL746C). The cover closes with two stainless steel lockable snap latches, and the snap latches include a provision for padlocking. The cover itself is clear injected polycarbonate, so the interior stays visible with the cover closed. A captive, oil resistant closed cell neoprene gasket provides a positive seal. The molded hinge uses a stainless steel hinge pin.
Nominal size is 14 in x 12 in x 6 in (356 mm x 305 mm x 152 mm); the enclosure measures 13.94 in (354 mm) high, 12.16 in (309 mm) wide and 5.98 in (152 mm) deep, with a shipping weight of 8 lbs (3.63 kg). Threaded #10-32 brass inserts are provided for mounting the optional PCJR1311 inner panel, which measures 12.75 in (324 mm) by 10.88 in (276 mm). The drawing lists optional back panel thicknesses of 0.100 in (2.54 mm) aluminum or 0.075 in (1.91 mm) white steel.
It is supplied with four polycarbonate flanges (glued) for surface mounting; the drawing shows 8X R.17 in (4.32 mm) flange slots with a slot distance of min 14.62 in (371.35 mm) / max 14.75 in (374.65 mm). Stainless steel 316 screw fasteners are used and mounting hardware is included. The clear-cover PCJ14126CCLF is UL 508A and cUL (CSA 22.2 No. 94) Type 1, 2, 3, 3R, 4, 4X, 12 and 13, meets the same NEMA types and IP66, is V-0 per UL 94, and is RoHS and REACH compliant. Operating temperatures run from -35 °C to 130 °C (-31 °F to 266 °F), with an impact index of 16 J (12 ft/lb).
Ideal For
- Industrial pump control enclosures
- Waste water treatment controls
- Irrigation control systems
- Solar and wind installations
- Chemical plant controls and components
Mounting
| Mounting Hardware | Included |
| Flange Slot Distance | Min 14.62 in (371.35 mm) / max 14.75 in (374.65 mm) |
| Flange/Feet Fastening | Four #10-32 brass inserts with stainless steel flange and feet screws |
| Multi-Directional Mounting | Available with polycarbonate flange or foot mount brackets |
Overview
| Series | PCJ Series |
| Closure | Metal latch cover (snap latch) |
| Cover Type | Clear polycarbonate cover |
| Product Type | Type 4X Polycarbonate Junction Box (Solid and Clear Cover) |
| Mounting Style | Flange |
| Long Description | Polycarb 14X12X6 Latch Clr w/Flange |
| Short Description | PC NON MET LATCH CLR FLANGE |
Dimensions
| Enclosure Depth | 5.98 in (152 mm) |
| Enclosure Width | 12.16 in (309 mm) |
| Enclosure Height | 13.94 in (354 mm) |
| Nominal Size (H X W X D) | 14 in x 12 in x 6 in (356 mm x 305 mm x 152 mm) |
Identifiers
| UPC | 623980982700 |
| UNSPSC | 39121324 |
| Part Number | PCJ14126CCLF |
| Related Versions (Same Size) | PCJ14126LF (Solid cover, flange); PCJ14126L (Solid cover, feet); PCJ14126CCL (Clear cover, feet) |
Inner Panel
| Inner Panel Mounting | Four #10-32 brass inserts with plated carbon steel truss screws |
| Optional Inner Panel Width | 10.88 in (276 mm) |
| Optional Inner Panel Height | 12.75 in (324 mm) |
| Optional Inner Panel Part No. | PCJR1311 |
| Optional Inner Panel Materials | White powder coated finished steel, unfinished aluminum, or fiberglass |
| Optional Back Panel Thicknesses | 0.100 in (2.54 mm) aluminum / 0.075 in (1.91 mm) white steel |
Packaging & Shipping
| Shipping Weight | 8 lbs (3.63 kg) |
Construction & Finish
| Hinge | Molded hinge; Stainless steel hinge pin |
| Finish | Polycarbonate material has a light gray finish |
| Gasket | Closed cell neoprene gasket; captive, oil resistant |
| Latches | Two stainless steel lockable snap latches; provision for padlocking |
| Box Material | Injected polycarbonate |
| Machinability | Easily punched, cut, or drilled |
| Screw Fasteners | Stainless steel 316 |
| Clear Cover Material | Injected polycarbonate |
| Standard Cover Material | Injected polycarbonate |
Environmental & Protection
| Impact Index | 16 J (12 ft/lb) |
| UV Resistance | UV rating (f1) per UL746C - UV stabilized for outdoor use; enhanced UV inhibitors |
| Ingress Protection | IEC 60529, IP66 |
| Operating Temperature | -35 °C to 130 °C (-31 °F to 266 °F) |
Compliance & Certifications
| UL | UL 508A Type 1, 2, 3, 3R, 4, 4X, 12 and 13 |
| CUL | cUL Type 1, 2, 3, 3R, 4, 4X, 12 and 13 per CSA 22.2 No. 94 |
| NEMA | Complies with NEMA Type 1, 2, 3, 3R, 4, 4X, 12 and 13 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Is the PCJ14126CCLF suitable for outdoor use?▾
Yes. It is UL 508A and cUL listed Type 1, 2, 3, 3R, 4, 4X, 12 and 13, rated IP66 per IEC 60529, and UV stabilized for outdoor use with a UV rating of f1 per UL746C.
What are the enclosure dimensions?▾
Nominal size is 14 in x 12 in x 6 in (356 mm x 305 mm x 152 mm). The enclosure measures 13.94 in (354 mm) high, 12.16 in (309 mm) wide and 5.98 in (152 mm) deep.
Which inner panel fits this box?▾
The optional inner panel is part number PCJR1311, measuring 12.75 in (324 mm) x 10.88 in (276 mm). It mounts on threaded #10-32 brass inserts; optional inner panels are available in white powder coated finished steel, unfinished aluminum, or fiberglass.
How is it mounted?▾
This version has four polycarbonate flanges (glued); flange slot distance is min 14.62 in (371.35 mm) / max 14.75 in (374.65 mm). Mounting hardware is included.
Can the cover be locked?▾
The cover uses two stainless steel lockable snap latches, and the snap latches include a provision for padlocking.
How is the clear cover version different from its siblings?▾
The PCJ14126CCLF has a clear polycarbonate cover with flange mounting. The same size is also offered as PCJ14126LF (Solid cover, flange), PCJ14126L (Solid cover, feet), PCJ14126CCL (Clear cover, feet).
Related Products
Save 31%PCJ14126CCL — Polycarb 14X12X6 Latch Clr w/Feet
Hammond Manufacturing · PCJ14126CCL
Save 31%PCJ14126L — Polycarb 14X12X6 Latch w/Feet
Hammond Manufacturing · PCJ14126L
Save 31%PCJ12126LF — PC Non Met Latch Flange
Hammond Manufacturing · PCJ12126LF
Save 31%PCJ14126LF — Polycarb 14X12X6 Latch w/Flange
Hammond Manufacturing · PCJ14126LF
Save 31%PCJ12126L — PC Non Met Latch Feet
Hammond Manufacturing · PCJ12126L