Hammond FLHTF1300A115 1300W 120V Enclosure Fan Heater, 50 CFM Thermostat
Ships from and sold by A5 IT
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- 1300 W heat output at 120 V, 60 Hz
- 50 CFM fan-forced airflow
- Built-in adjustable thermostat, -18 C to +38 C (0 F to +100 F)
- Fan Auto/On switch with pilot light for Heat On indication
- Automatic reset temperature limit switch for overheat or fan failure
- Aluminum alloy outer casing, terminal block connection
- 7.5" x 5.6" x 6.9" overall (H x W x D)
- cULus Recognized to UL 508A and C22.2 No. 14-13
The FLHTF1300A115 is a fan-forced enclosure heater with a built-in thermostat, rated 1300 W on 120 V, 60 Hz and moving 50 CFM. It is designed to prevent condensation or maintain a minimum temperature inside a control panel or metal enclosure, protecting critical components from freezing and condensation. It is not intended as a comfort or space heater.
As one of the 1300 W models in the FLH series, it has the larger housing at 7.5" x 5.6" x 6.9" (H x W x D) in the ordering table, with 189.87 mm [7.475 in] x 141.61 mm [5.575 in] x 173.86 mm [6.845 in] shown on the drawing, and it moves more air than the smaller sizes. Its approval is cURus/cULus only: the drawing lists cULus Recognized to UL 508A and C22.2 No. 14-13.
The outer casing is aluminum alloy. The adjustable thermostat covers -18 C to +38 C (0 F to +100 F), and a Fan Auto/On switch with pilot light shows when heat is on. In FAN mode the fan runs continuously for more uniform temperature distribution and heat is still provided below the set point; in AUTO mode the fan cycles on only when the heating element is energized. An automatic reset temperature limit switch breaks power to the element on fan failure or overheat.
Mount the FLHTF1300A115 vertically inside a metal enclosure on a metal surface, terminal block at the bottom and discharge vents at the top, using four #10 metal screws, as low and central as possible. Keep heat-sensitive components clear of the vents by the FLHTF1300 clearances (10in / 250mm X, 4in / 100mm Y). Wiring is by qualified personnel with wire rated at least 90°C; there is no OFF position, so disconnect supply power to shut it down.
Ideal For
- Preventing condensation in control panels
- Maintaining minimum temperature in metal enclosures
- Freeze protection for critical enclosure components
- Industrial control panel heating
Overview
| Description | 1300W Heater 120Vac w/ Tstat |
| Product Type | Fan-forced enclosure heater with thermostat (FLH Series) |
| Short Description | ENCLOSURE HEATER 1300W, 120VAC |
Dimensions
| Drawing Depth | 173.86 mm [6.845 in] |
| Drawing Width | 141.61 mm [5.575 in] |
| Drawing Height | 189.87 mm [7.475 in] |
| Size H X W X D (Part Page) | 7.5 in x 6 in x 6 in (191 mm x 152 mm x 152 mm) |
| Overall Dimensions (H X W X D) | 7.5" x 5.6" x 6.9" |
Electrical
| Watts | 1300 W |
| Wiring | Wires rated no less than 90°C; wired by qualified personnel to local electrical code; connect to a grounded source only |
| Voltage | 120 V |
| Frequency | 60 Hz |
| Connection | Terminal block |
| Power Switch | No OFF position; disconnect supply power to shut down |
| Drawing Rating | 120 VAC, 60 Hz, 1300 W |
Identifiers
| UPC | 623980031798 |
| UNSPSC | 40101819 |
Performance
| Airflow | 50 CFM |
| Fan Modes | FAN (continuous) / AUTO (fan runs only when heating element is energized) |
| Heat Indicator | Pilot light for Heat On indication |
| Thermostat Range | -18 C to +38 C (0 F to +100 F) |
| Fan Motor Bearings | Permanently lubricated |
| Overheat Protection | Automatic reset temperature limit switch (TCO disc) opens on overheat or fan failure |
Installation
| Location | Centre of the enclosure, as low as possible |
| Mounting | Inside a metal enclosure on a metal surface, vertical position, terminal block at bottom and discharge vents at top |
| Fasteners | Four #10 metal screws |
| Clearance To Heat-Sensitive Components | X: 10in / 250mm; Y: 4in / 100mm |
Packaging & Shipping
| Included | Operation and Installation Instruction sheet |
| Shipping Weight | 3.5 lbs (1.59 kg) |
Construction & Finish
| Housing | Aluminum alloy |
Environmental & Protection
| Environment | Interior use, dry locations; not for hazardous, corrosive, dusty or wet environments |
| Storage Temperature | -30°C to +100°C (-22°F to 212°F) |
| Operating Temperature | -20°C to +70°C (-4°F to 158°F) |
Compliance & Certifications
| Approvals | cULus Recognized Standard UL 508A & C22.2 No. 14-13 |
| UL File # | E331157 |
| Approval Note | 1300W models are cURus approved only |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
What is the heat output and supply voltage of the FLHTF1300A115?▾
It is rated 1300 W at 120 V, 60 Hz. The drawing rating reads 120 VAC, 60 Hz, 1300 W.
Does it have a built-in thermostat?▾
Yes. The adjustable thermostat is built in and covers -18 C to +38 C (0 F to +100 F).
How is it mounted?▾
Vertically inside a metal enclosure on a metal surface, terminal block at the bottom, using four #10 metal screws. Keep heat-sensitive components at least 10in / 250mm (X) and 4in / 100mm (Y) from the discharge vents.
Can I switch it off at the heater?▾
No. The heater does not have an OFF position; power must be disconnected from the supply to fully shut it down. The Fan Auto/On switch only selects whether the fan runs continuously or cycles with the heating element.
What happens if the fan fails?▾
An automatic reset temperature limit switch opens on fan failure or overheat, disconnecting power to the heating element until the enclosure temperature drops below the limit.
What approvals does it carry?▾
The drawing lists cULus Recognized to UL 508A and C22.2 No. 14-13; 1300W models are cURus approved only. UL File # E331157.
Related Products
Save 31%FLHTF125A230 — 125W Heater, 230V w/Tstat
Hammond Manufacturing · FLHTF125A230
Save 31%FLHTF1300A230 — 1300W Heater, 220/240Vac w/ Tstat
Hammond Manufacturing · FLHTF1300A230
Save 31%FLHTF125A115 — 125W Heater, 115V w/Tstat
Hammond Manufacturing · FLHTF125A115
Save 31%FLHTF200A115 — 200W Heater, 115V w/Tstat
Hammond Manufacturing · FLHTF200A115
Save 31%FLHTF200A230 — 200W Heater, 230V w/Tstat
Hammond Manufacturing · FLHTF200A230