(224) 955-1644
Hammond ManufacturingAuthorized partner store
DTT6801B460LG 14,500 BTU/h 400/460 V three-phase top-mount enclosure air conditioner, RAL 7035

Hammond DTT6801B460LG 14,500 BTU/h 400/460V Top-Mount Air Conditioner

Hammond Manufacturing|

MPN: DTT6801B460LG

|

UPC: 623980336343

Available on Backorder
$7,531.18

Ships from and sold by A5 IT

Available on backorder — ships as soon as stock arrives

Freight Delivery · $398.99Ships as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 14,500 BTU/h (4250 W) at +95/+95F; 4000 W at 50 Hz A35/A35
  • 400/460 V three-phase, 50/60 Hz; 1601 / 1989 W power consumption
  • Top mounting over a 27.24 x 15.43 in (692 x 392 mm) cutout
  • Maintains NEMA 12; IP 54 to enclosure, IP 34 to environment; UR, cUR, CE
  • 3260 / 3495 W capacity at A50/A35 (50/60 Hz)
  • 1250 g R134a; hot gas bypass valve; 62 dB(A) at 1 m
  • Galvanized, powder coated RAL 7035 finish

The DTT6801B460LG is the highest-capacity model in the DTT 7000-14000 BTU/H top-mount indoor air conditioner series. Rated 14,500 BTU/h (4250 Watts) at +95/+95F (+35/+35C) on a 400/460 V three-phase supply, it is built for OEMs, integrators and plant engineers cooling large, heavily loaded NEMA 12 enclosures from the roof when side mounting is not an option. The part page describes it as AIR CONDIT 14000BTU 460V LG.

According to the unit's technical data, cooling capacity at A35/A35 is 4000 W at 50 Hz and 4250 W at 60 Hz, and at A50/A35 it is 3260 W and 3495 W. Power consumption is 1601 W at 400 V/50 Hz and 1989 W at 460 V/60 Hz, with nominal current of 4.6 A / 4.5 A and starting current of 17.1 A / 19.5 A. The refrigerant is R134a (1250 g charge). External air volume is 1970/2180 m³/h and internal air volume 1420/1530 m³/h (50/60 Hz), with a 62 dB(A) noise level at 1 m.

  • Closed loop cooling; enclosure air never mixes with contaminated ambient air
  • Patented condensate management with built-in condensate evaporation
  • Thermostat factory set +35°C (+95°F), adjustable +77…+113F; failure indication above +50°C (+122°F)
  • Hot gas bypass valve, self-diagnostics on startup, LED fault indication, door contact input

The DTT6801B460LG measures 19.09 in (485 mm) H x 31.30 in (795 mm) W, with depth listed as 22.64 in (575 mm) on the part page and 22.60 in (574 mm) in the ordering table, and fits a 27.24 x 15.43 in (692 x 392 mm) cutout. It installs vertically with at least 200 mm clearance, weighs 77 kg per the data sheet and ships at 175 lbs (79.38 kg). The steel and plastic unit is galvanized and powder coated in RAL 7035, maintains NEMA 12, is IP 54 toward the enclosure and IP 34 toward the environment, and carries UR, cUR and CE.

Ideal For

  • High heat load NEMA 12 enclosures on 400/460 V three-phase power
  • Roof mounted cooling where side mounting is not possible
  • Industrial drive, power and process control cabinets
  • Closed loop cooling in contaminated ambient environments

Overview

SeriesDTT Series 7000-14000 BTU/H Indoor Air Conditioner, Type 12, Top Mounting
ControlsThermostat control accessible from inside enclosure
DiagnosticsSelf-diagnostics on startup; fault indication via LED light
Filter MatsOptional; cooling performance is reduced when filter mats are used
RefrigerantR134a
Spare PartsInternal fan 18811100078; external fan 18811000049; display unit 18810000001; control unit 18810000058; cover 18810200140; stainless steel cover 18810200143
Door ContactProvision for door contact allowing power down when enclosure door is opened (no external voltage to be applied to door contact)
Cooling MethodClosed loop cooling; enclosure air is recirculated without mixing with ambient air
Hot Gas BypassHot gas bypass valve prevents evaporator freeze up while minimizing heavy inrush currents on large BTU/H units
Air CirculationContinuous air circulation from high capacity fans
Mounting PositionTop mounting (for where space does not allow side mounting on the enclosure surface)
Short DescriptionAIR CONDIT 14000BTU 460V LG
Condensate EvaporatorBuilt in
Condensate ManagementPatented condensate management system prevents condensate from penetrating the enclosure; condensate evaporation

Dimensions

Size (H X W X D)19.09 in x 31.3 in x 22.64 in (485 mm x 795 mm x 575 mm)
Cutout Dimension D15.43 in (392 mm)
Cutout Dimension W27.24 in (692 mm)
Overall Dimension B (Width)31.30 in (795 mm)
Overall Dimension C (Depth)22.60 in (574 mm)
Overall Dimension A (Height)19.09 in (485 mm)
Depth With Cover And PFA (Technical Data)575 mm

Electrical

Frequency50/60 Hz
Operating RangeDIN IEC 60038
Starting Current17.1 A (400 V/50 Hz); 19.5 A (460 V/60 Hz)
Electrical ConnectionTerminal Block with Plug
Rated Voltage (+/- 10%)400/460 V 3~
Cooling Capacity At A35/A354000 W (50 Hz); 4250 W (60 Hz)
Cooling Capacity At A50/A353260 W (50 Hz); 3495 W (60 Hz)
Power Consumption (A35/A35)1601 W (400 V/50 Hz); 1989 W (460 V/60 Hz)
Running Amps / Nominal Current4.6 A (400 V/50 Hz); 4.5 A (460 V/60 Hz)
Cooling Capacity (+95/+95F, +35/+35C)14500 BTU/h (4250 Watts)

Identifiers

UPC623980336343
UNSPSC39121301

Performance

Refrigerant Amount1250 g
Air Volume, External Circulation1970 m³/h (50 Hz); 2180 m³/h (60 Hz)
Air Volume, Internal Circulation1420 m³/h (50 Hz); 1530 m³/h (60 Hz)

Installation

Minimum Clearance200 mm between units and from the wall; air inlet and outlet inside the enclosure must not be obstructed
Mounting HardwareMounting via tool-less sash fasteners
Installation PositionVertical

Packaging & Shipping

IncludedGasket, mounting kit and template for enclosure cutout and drilling; condensate drain hose and clamp
Shipping Weight175 lbs (79.38 kg)
Optional AccessoriesRemote Door Switches, Gasket Kits, Water Condensate Evaporator, Condensate Bottle
Transport & Storage PositionUpright (operating position) only
Unit Weight (Technical Data)77 kg

Construction & Finish

Finish (LG)Galvanized Sheet Steel Color RAL 7035 Powder Finish
Unit ConstructionSteel / plastic
Corrosion ProtectionGalvanized, electrostatically powder coated (200°C)

Environmental & Protection

Enclosure RatingMaintains NEMA 12 rating
Noise Level (1 M)62 dB(A)
Adjustable Control Range+77… +113F (+25…+45C)
Protection ClassificationIP 54 against the enclosure; IP 34 against the environment (EN 60529), under correct operating conditions
Thermostat Factory Setting+95F / +35C
Min/Max Ambient Temperature+59...+131 F / +15...+55 C
Enclosure Internal Temperature+25°C (+77°F) ... +50°C (+122°F)
Failure Indication (Enclosure Internal Temp, Factory Set)> +50°C (+122°F)

Compliance & Certifications

ApprovalsUR, cUR and CE
RoHS CompliantYes
REACH CompliantYes
EMI/RFI SuppressionMeets CE

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

How much cooling does the DTT6801B460LG provide?▾

14,500 BTU/h (4250 Watts) at +95/+95F (+35/+35C) per the series spec sheet; 4000 W (50 Hz) / 4250 W (60 Hz) at A35/A35 and 3260 W / 3495 W at A50/A35 per the technical data.

What power supply does it need?▾

400/460 V three-phase (3~), 50/60 Hz, rated +/- 10%.

What are the current ratings?▾

4.6 A nominal and 17.1 A starting at 400 V/50 Hz; 4.5 A nominal and 19.5 A starting at 460 V/60 Hz.

Is it the same size as the DTT6601B460LG?▾

Both share 19.09 in x 31.30 in height and width and the 27.24 x 15.43 in cutout. The ordering table lists the DTT6801B460LG depth as 22.60 in (574 mm).

What spare parts are listed?▾

Internal fan 18811100078, external fan 18811000049, display unit 18810000001, control unit 18810000058, cover 18810200140 and stainless steel cover 18810200143.