DTT6601B460LG 11,000 BTU/h 400/460 V three-phase top-mount enclosure air conditioner, RAL 7035

Hammond DTT6601B460LG 11,000 BTU/h 400/460V Top-Mount Air Conditioner

Hammond Manufacturing|

MPN: DTT6601B460LG

|

UPC: 623980336336

In Stock
$6,075.92

Ships from and sold by A5 IT

Freight Delivery · $396.99Arrives by Monday, Nov 2
Order within 1h 48m to get it by Monday, Nov 2
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 11,000 BTU/h (3200 W) at +95/+95F; 3000 W at 50 Hz A35/A35
  • 400/460 V three-phase, 50/60 Hz; 1700 / 2100 W power consumption
  • Top mounting over a 27.24 x 15.43 in (692 x 392 mm) cutout
  • Maintains NEMA 12; IP 54 to enclosure, IP 34 to environment; UR, cUR, CE
  • 1250 g R134a charge; hot gas bypass valve; 62 dB(A) at 1 m
  • Failure indication above +50°C (+122°F) enclosure temperature
  • Galvanized, powder coated RAL 7035 steel/plastic construction

The DTT6601B460LG is a three-phase 400/460 V top-mount air conditioner for industrial enclosures in the DTT 7000-14000 BTU/H indoor series. It suits OEM machine builders, panel shops and plant engineers who need to take a large heat load out of a NEMA 12 control enclosure from the roof, where side mounting space is not available. The Hammond spec sheet rates it at 11,000 BTU/h (3200 Watts) at +95/+95F (+35/+35C); the part page describes it as a 10700BTU unit.

The unit's technical data sheet gives cooling capacity at A35/A35 of 3000 W at 50 Hz and 3200 W at 60 Hz, and at A50/A35 of 2000 W and 2250 W. On 400 V/50 Hz it draws 1700 W with 3.16 A nominal current and 8.9 A starting current; on 460 V/60 Hz the figures are 2100 W, 4.5 A and 9.9 A. It uses 1250 g of R134a refrigerant and moves 1970/2180 m³/h of external air and 1420/1530 m³/h of internal air (50/60 Hz). Noise level is 62 dB(A) at 1 m.

Closed loop cooling keeps enclosure air separate from contaminated ambient air, and the patented condensate management system with condensate evaporation keeps water out of the cabinet. The thermostat is factory set at +35°C (+95°F) and adjustable +77 to +113F; a failure indication triggers above +50°C (+122°F) enclosure temperature. Self-diagnostics, LED fault indication, a hot gas bypass valve and a door contact input (no external voltage) are standard.

Overall size is 19.09 in (485 mm) H x 31.30 in (795 mm) W x 22.64 in (575 mm) D, with a 27.24 x 15.43 in (692 x 392 mm) cutout. The unit installs vertically, needs at least 200 mm clearance to walls and other units, and weighs 75 kg per the data sheet (shipping weight 170 lbs / 77.11 kg). Construction is steel and plastic, galvanized and electrostatically powder coated in RAL 7035. The DTT6601B460LG maintains NEMA 12, is IP 54 toward the enclosure and IP 34 toward the environment, and carries UR, cUR and CE.

Ideal For

  • Cooling large NEMA 12 industrial control enclosures on 400/460 V three-phase power
  • Top mounting where side mounting space is not available
  • Machine and process control cabinets with high heat loads
  • Enclosures in contaminated ambient air requiring closed loop cooling

Overview

SeriesDTT Series 7000-14000 BTU/H Indoor Air Conditioner, Type 12, Top Mounting
ControlsThermostat control accessible from inside enclosure
DiagnosticsSelf-diagnostics on startup; fault indication via LED light
Filter MatsOptional; cooling performance is reduced when filter mats are used
RefrigerantR134a
Spare PartsInternal fan 18811100078; external fan 18811000049; display unit 18810000001; control unit 18810000058; cover 18810200140; stainless steel cover 18810200143
Door ContactProvision for door contact allowing power down when enclosure door is opened (no external voltage to be applied to door contact)
Cooling MethodClosed loop cooling; enclosure air is recirculated without mixing with ambient air
Hot Gas BypassHot gas bypass valve prevents evaporator freeze up while minimizing heavy inrush currents on large BTU/H units
Air CirculationContinuous air circulation from high capacity fans
Mounting PositionTop mounting (for where space does not allow side mounting on the enclosure surface)
Short DescriptionAIR CONDIT 10700BTU 460V LG
Condensate EvaporatorBuilt in
Condensate ManagementPatented condensate management system prevents condensate from penetrating the enclosure; condensate evaporation

Dimensions

Size (H X W X D)19.09 in x 31.3 in x 22.64 in (485 mm x 795 mm x 575 mm)
Cutout Dimension D15.43 in (392 mm)
Cutout Dimension W27.24 in (692 mm)
Overall Dimension B (Width)31.30 in (795 mm)
Overall Dimension C (Depth)22.64 in (575 mm)
Overall Dimension A (Height)19.09 in (485 mm)
Depth With Cover And PFA (Technical Data)575 mm

Electrical

Frequency50/60 Hz
Operating RangeDIN IEC 60038
Starting Current8.9 A (400 V/50 Hz); 9.9 A (460 V/60 Hz)
Electrical ConnectionTerminal Block with Plug
Rated Voltage (+/- 10%)400/460 V 3~
Cooling Capacity At A35/A353000 W (50 Hz); 3200 W (60 Hz)
Cooling Capacity At A50/A352000 W (50 Hz); 2250 W (60 Hz)
Power Consumption (A35/A35)1700 W (400 V/50 Hz); 2100 W (460 V/60 Hz)
Running Amps / Nominal Current3.16 A (400 V/50 Hz); 4.5 A (460 V/60 Hz)
Cooling Capacity (+95/+95F, +35/+35C)11,000 BTU/h (3200 Watts)

Identifiers

UPC623980336336
UNSPSC39121301

Performance

Refrigerant Amount1250 g
Air Volume, External Circulation1970 m³/h (50 Hz); 2180 m³/h (60 Hz)
Air Volume, Internal Circulation1420 m³/h (50 Hz); 1530 m³/h (60 Hz)

Installation

Minimum Clearance200 mm between units and from the wall; air inlet and outlet inside the enclosure must not be obstructed
Mounting HardwareMounting via tool-less sash fasteners
Installation PositionVertical

Packaging & Shipping

IncludedGasket, mounting kit and template for enclosure cutout and drilling; condensate drain hose and clamp
Shipping Weight170 lbs (77.11 kg)
Optional AccessoriesRemote Door Switches, Gasket Kits, Water Condensate Evaporator, Condensate Bottle
Transport & Storage PositionUpright (operating position) only
Unit Weight (Technical Data)75 kg

Construction & Finish

Finish (LG)Galvanized Sheet Steel Color RAL 7035 Powder Finish
Unit ConstructionSteel / plastic
Corrosion ProtectionGalvanized, electrostatically powder coated (200°C)

Environmental & Protection

Enclosure RatingMaintains NEMA 12 rating
Noise Level (1 M)62 dB(A)
Adjustable Control Range+77… +113F (+25…+45C)
Protection ClassificationIP 54 against the enclosure; IP 34 against the environment (EN 60529), under correct operating conditions
Thermostat Factory Setting+95F / +35C
Min/Max Ambient Temperature+59...+131 F / +15...+55 C
Enclosure Internal Temperature+25°C (+77°F) ... +50°C (+122°F)
Failure Indication (Enclosure Internal Temp, Factory Set)> +50°C (+122°F)

Compliance & Certifications

ApprovalsUR, cUR and CE
RoHS CompliantYes
REACH CompliantYes
EMI/RFI SuppressionMeets CE

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the cooling capacity of the DTT6601B460LG?▾

The series spec sheet rates it at 11,000 BTU/h (3200 Watts) at +95/+95F (+35/+35C). The technical data lists 3000 W (50 Hz) / 3200 W (60 Hz) at A35/A35 and 2000 W / 2250 W at A50/A35.

Is it single-phase or three-phase?▾

Three-phase: rated 400/460 V 3~ at 50/60 Hz.

What current does it draw?▾

3.16 A nominal and 8.9 A starting at 400 V/50 Hz; 4.5 A nominal and 9.9 A starting at 460 V/60 Hz.

What cutout and clearances does it need?▾

A 27.24 in x 15.43 in (692 x 392 mm) cutout, vertical installation, and at least 200 mm between units and from the wall, with the internal air inlet and outlet unobstructed.

Will filter mats affect performance?▾

Yes. The data sheet notes that cooling performance is reduced when optional filter mats are used.

How loud is it?▾

The noise level is 62 dB(A) at 1 m.