Hammond DTS3161SLA2N3LG 230V Type 3R/4 Outdoor Slimline Air Conditioner
Ships from and sold by A5 IT
Available on backorder — ships as soon as stock arrives
Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business AccountKey Features
- Type 3R, 4 rated outdoor slimline unit in RAL7035 light gray
- 5648 BTU/h (1654 W) cooling at +95/+95 °F (+35/+35 °C)
- 230 V 50/60 Hz, 198-253 V, 890 W, 4.49 A running, 14.8 A starting
- Ambient range +32 °F (0 °C) to +131 °F (+55 °C)
- Thermostat +59 to +113 °F (+15 to +45 °C), accessible inside the enclosure
- Closed loop cooling with 350 CFM internal and external airflow, filterless
- UL, cUL and CE; gasket, mounting kit and template included
The DTS3161SLA2N3LG is a 230 V, 50/60 Hz outdoor slimline air conditioner with a Type 3R, 4 rating and RAL7035 light gray finish. Part of the DTS SL outdoor series, it side mounts on any enclosure surface where hot spot or low capacity cooling is required, making it suitable for outdoor control and electrical enclosures specified by integrators and facilities teams.
Rated cooling capacity is 5648 BTU/h (1654 W) at +95/+95 °F (+35/+35 °C). Closed loop cooling keeps clean enclosure air recirculating without mixing with contaminated ambient air, and high capacity fans provide 350 CFM of internal and 350 CFM of external circulation (unrestricted). The R134a circuit holds a 700 g charge and uses an expansion valve to improve evaporator heat transfer with less frequent compressor operation.
It operates from 198-253 V, consumes 890 W, and draws 4.49 A running and 14.8 A at start, wired through a terminal block. The thermostat, accessible from inside the enclosure, adjusts from +59 to +113 °F (+15 to +45 °C) with a +95 °F (+35 °C) factory setting. The outdoor model is specified for ambient air from +32 °F (0 °C) up to +131 °F (+55 °C). It is filterless, removes condensate with a condensate evaporator and runs under 70 dB(A).
The case is galvanized sheet steel and the unit weighs 108 lbs (49 kg); shipping weight is 113 lbs (51.26 kg). UL, cUL and CE approvals apply, and the DTS3161SLA2N3LG includes startup self-diagnostics, LED fault indication, door-contact power-down, the gasket, mounting kit and template, plus a condensate drain hose and clamp.
Ideal For
- Cooling outdoor Type 3R and Type 4 enclosures
- Hot spot cooling on outdoor control cabinets
- Low capacity side-mounted enclosure cooling on 230 V supplies
Cooling
| Filter Mat | Filterless |
| Refrigerant | R134a |
| Cooling Method | Closed loop - clean enclosure air is recirculated without mixing with ambient air |
| Air Circulation | Continuous, from high capacity fans |
| Expansion Valve | Improves evaporator heat transfer with less frequent compressor operation |
| Refrigerant Charge | 700 g |
| Condensate Discharge | Condensate evaporator |
| Condenser/Evaporator | Built in |
| Air Capacity (Unrestricted) | Internal circulation 350 CFM; external circulation 350 CFM |
| Cooling Capacity (+95/+95 F, +35/+35 C) | 5648 BTU/h (1654 W) |
Controls
| Thermostat | Accessible from inside enclosure |
| Diagnostics | Self-diagnostics on startup; fault indication via LED light |
| Door Contact | Powers the unit down when the enclosure door is opened |
| Factory Setting | +95 °F (+35 °C) |
| Adjustable Control Range | +59 to +113 °F / +15 to +45 °C |
Overview
| Series | DTS SL Series - 3000-5000 BTU/H Outdoor Slimline Air Conditioner, Type 3R, 4, 4X, Side Mounting |
| Part Number | DTS3161SLA2N3LG |
| Long Description | AC Unit 3500-5000 BTU/H 230 V - NEMA 3R/4 - Lt. Gray |
| Drawing Tolerance | ISO 2768-m |
| Reference Drawing | DTS 31x5 W/ Rain Shield, drawing 30240-600 01 |
| Short Description | AIR CONDIT 3500BTU 230V LG |
| Optional Accessories | Remote door switches, filter kits, gasket kits, water condensate evaporator, condensate bottle |
Dimensions
| Unit Weight | 108 lbs (49 kg) |
| Drawing Units | mm [inch] |
| Drawing Dimension | 838.20 mm (33.00 in) |
| Drawing Dimension (Width) | 366.16 mm (14.42 in) |
| Drawing Dimensions (Other) | 312 mm (12.28 in); 310.90 mm (12.24 in); 302.21 mm (11.90 in); 279.40 mm (11.00 in); 245.66 mm (9.67 in); 243.62 mm (9.59 in) |
| Drawing Largest Overall Dimension | 917.03 mm (36.10 in) |
Electrical
| Line Cord | Terminal Block |
| Running Amps | 4.49 A |
| Rated Voltage | 230 V 50/60 Hz |
| Starting Current | 14.8 A |
| Power Consumption | 890 W |
| Range Of Operation | 198-253 V |
| EMI/RFI Suppression | Meets CE |
Identifiers
| UPC | 623980568195 |
| UNSPSC | 40101701 |
Installation
| Mounting | Side mounting on any enclosure surface |
Packaging & Shipping
| Included | Gasket, mounting kit and template for cutout and drilling; condensate drain hose and clamp |
| Shipping Weight | 113 lbs (51.26 kg) |
Construction & Finish
| Finish | RAL7035 light gray (LG) |
| Exterior Case | Galvanized sheet steel |
| Alternate Finish | ANSI 61 Gray - replace LG with GY in the part number |
| Drawing Material | 18GA galvanized; CRS powder coated |
Environmental & Protection
| Noise Level | <70 dB(A) |
| Max Ambient Air Temp | +131 °F (+55 °C) |
| Min Ambient Air Temp | +32 °F (0 °C) |
| IP Rating (Series Standards) | IP 56 |
Compliance & Certifications
| Approvals | UL, cUL and CE |
| Type Rating | 3R, 4 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| NEMA Rating (Series Spec Table) | Enclosures IP 54/Nema 3R, 4, 4X |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Frequently Asked Questions
Can the DTS3161SLA2N3LG be used outdoors?▾
Yes. It is part of the outdoor slimline series and carries a Type 3R, 4 rating, with ambient limits of +32 °F (0 °C) to +131 °F (+55 °C).
What is the cooling capacity?▾
5648 BTU/h (1654 W) at +95/+95 °F (+35/+35 °C).
What are the electrical ratings?▾
230 V 50/60 Hz, operating range 198-253 V, 890 W, 4.49 A running and 14.8 A starting, terminal block connection.
How is the temperature set?▾
The thermostat is accessible from inside the enclosure and adjusts from +59 to +113 °F (+15 to +45 °C); factory setting is +95 °F (+35 °C).
Is there a gray ANSI 61 version?▾
The series notes that the ANSI 61 Gray finish is ordered by replacing LG with GY.
Related Products
Save 31%DTS3161SLA4N3LG — Air Conditioner 3500 BTU 460V LG
Hammond Manufacturing · DTS3161SLA4N3LG
Save 31%DTS3181SLA2N4SS — AC Unit 3500-5000 BTU/H 230 V - NEMA 4X - 304SS
Hammond Manufacturing · DTS3181SLA2N4SS
Save 31%DTS3181SLA4N4SS — AC Unit 3500-5000 BTU/H 460 V - NEMA 4X - 304SS
Hammond Manufacturing · DTS3181SLA4N4SS