Hammond C2T1936F10CEBK1 black steel rack cabinet fan top panel with pre-wired 10 in 550 CFM fan, chrome finger guard and covered cable entry grommet holes

Hammond C2T1936F10CEBK1 550 CFM Pre-Wired 10 in Fan Top With Cable Entry

Hammond Manufacturing|

MPN: C2T1936F10CEBK1

|

UPC: 623980333991

In Stock
$272.58

Ships from and sold by A5 IT

Ground Shipping · $53.99Arrives by Monday, Oct 26
Order within 3h 29m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • One factory pre-wired 10 in ball bearing AC fan delivering 550 CFM free-flow air at 60 dB
  • Cable entry grommets and covered access holes allow overhead cabling alongside active cooling
  • Rated 115 VAC, 50/60 Hz, 0.29 A with a 6 ft power cord for direct plug-in operation
  • 14-gauge mild steel panel, 717.55 mm [28.250 in] x 508.00 mm [20.000 in], black RAL9005 powder coat
  • Chrome plated fan finger guard; GREENGUARD, TSCA and RoHS compliant finish
  • cURus Recognized to UL507 and CSA C22.2 No.113; TAA-compliant, made in North America
  • Mounts with 6 supplied 8-32 x 1/2 in round head screws and 6 speed nuts using only a Phillips screwdriver
  • Fits C2, C2RR, C4, C4RR_A, C4RR_S, C4RR_D, H1, RCK and CLC cabinet series (H1 needs H1TC Series)

The C2T1936F10CEBK1 is a factory pre-wired fan top panel for rack cabinets, combining a single 10 in axial fan rated at 550 CFM free-flow air delivery with cable entry grommets in one panel. It is intended for IT, network, telecom, AV and broadcast teams that need to add active cooling to a cabinet while still bringing cables in through the top.

The panel is formed from 14-gauge mild steel with a black RAL9005 powder coat finish (GREENGUARD, TSCA and RoHS compliant), and the fan finger guard is chrome plated. Overall panel dimensions are 717.55 mm [28.250 in] by 508.00 mm [20.000 in], with a 228.60 mm [9.000 in] fan cutout and 93.47 mm [3.680 in] covered access holes for cable routing. Shipping weight is 23 lbs (10.43 kg).

The fan is wired at the factory and terminated in a 6 ft power cord, rated 115 VAC, 50/60 Hz, 0.29 A, with a measured sound level of 60 dB. No thermostat is included on this model; thermostat-controlled versions are offered elsewhere in the C2TF Series.

Installation is straightforward: U-clip nuts are installed on top of the cabinet frame, the panel is set in place and secured with the supplied 8-32 x 1/2 in round head screws, then tightened with a Phillips screwdriver. Hardware supplied with C2T1936F10CEBK1 consists of 6 screws and 6 speed nuts, and the series includes CLPKIT832-6 cabinet mounting hardware.

This 36 in depth fan top is designed for use with C2, C2RR, C4, C4RR_A, C4RR_S, C4RR_D, H1, RCK or CLC cabinet series (H1 requires the H1TC Series for mounting); the C2T1936 size suits C2 cabinets 23.00 in wide by 36.00 in deep. The panel is cURus Recognized to UL507 and CSA C22.2 No.113 and is TAA-compliant, manufactured in North America.

Ideal For

  • Adding active cooling to rack cabinets in data centers and IT rooms
  • High-density rack deployments with high heat load equipment
  • Network and telecom installations needing top cable entry plus airflow
  • AV and broadcast cabinet cooling
  • Upgrading passive cabinets to active cooling environments

Cooling

Fan Size10.00 in (254 mm)
Fan WiringFactory pre-wired
Cable EntryYes
Sound Level60 dB
Fan Quantity1
Thermostat IncludedNo
Free Flow Air Delivery550 CFM

Overview

SeriesC2TF Series Rack Cabinet Fan Top Panel
DescriptionPre-wired fan with cable entry grommets
Part NumberC2T1936F10CEBK1
Beige EquivalentC2T1936F10CECG1
Short Description550CFM FANTOP W/CABLE ENTRY
Light Gray EquivalentC2T1936F10CELG1 (ASA61 Light Gray)

Dimensions

Panel Width508.00 mm [20.000 in]
Access HolesWith cover
Panel Length717.55 mm [28.250 in]
Fan Cutout Diameter228.60 mm [9.000 in]
Cable Entry / Access Hole Diameter93.47 mm [3.680 in]

Electrical

Rating115 VAC, 50/60 Hz, 0.29 Amps
Power Cord6 ft power cord

Identifiers

UPC623980333991
UNSPSC43201618
GTIN-1400623980333991
UPC W/o Check Digit62398033399

Rack Mounting

Mounting KitIncludes CLPKIT832-6 cabinet mounting hardware
Assembly MethodInstall 8-32 U-clip nuts on cabinet frame, place panel, install and tighten 8-32 x 1/2 screws
Supplied Hardware6 screws - Round Head 8-32 x 1/2 in; 6 speed nuts
Cabinet CompatibilityC2, C2RR, C4, C4RR_A, C4RR_S, C4RR_D, H1, RCK or CLC cabinet series (H1 requires H1TC Series for mounting)
C2 Cabinet Size (C2T1936)23.00 in width, 36.00 in depth

Packaging & Shipping

Tariff Code8414.90.9180
Shipping Weight23 lbs (10.43 kg)
Country Of OriginCA

Construction & Finish

Gauge14-gauge steel construction
MaterialMild Steel
Top FinishPainted steel, RAL9005 Black powder coat
Finish ComplianceGREENGUARD, TSCA, RoHS compliant
Finger Guard FinishChrome plated

Compliance & Certifications

ECCNEAR99
ApprovalscURus Recognized UL507 and CSA C22.2 No.113
Standardscruus, taa-compliant
RoHS CompliantYes
REACH CompliantYes
USMCA CompliantNo

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

Does C2T1936F10CEBK1 come with the fan already installed and wired?▾

Yes. It is a pre-wired fan top with one 10 in fan factory wired and terminated in a 6 ft power cord, rated 115 VAC, 50/60 Hz, 0.29 Amps.

How much air does it move and how loud is it?▾

The fan is rated at 550 CFM free flow air delivery with a sound level of 60 dB.

Does this model include a thermostat?▾

No. Thermostat Included is listed as No for C2T1936F10CEBK1. Within the C2TF Series, the 4.7 in fan versions are available with or without adjustable thermostats.

Can I route cables through this fan top?▾

Yes. This version includes cable entry grommets, with 93.47 mm [3.680 in] access holes with cover, so cooling and top cable entry can be combined.

Which cabinets does it fit?▾

It is designed for use with C2, C2RR, C4, C4RR_A, C4RR_S, C4RR_D, H1, RCK or CLC cabinet series; H1 requires the H1TC Series for mounting. The C2T1936 size corresponds to a C2 cabinet 23.00 in wide by 36.00 in deep.

What hardware and tools are needed to install it?▾

Six 8-32 x 1/2 in round head screws and six speed nuts are supplied (CLPKIT832-6 cabinet mounting hardware). Install the U-clip nuts on the cabinet frame, set the panel in place and tighten the screws with a Phillips screwdriver.

Is this part available in another colour?▾

Yes. The same panel is offered as C2T1936F10CELG1 in ASA61 Light Grey and C2T1936F10CECG1 in Beige.