Hammond 714 200 VA 1,020V C.T. high voltage plate transformer, enclosed 4 hole chassis mount

Hammond 714 200 VA 1,020V C.T. Plate Transformer, 115 VAC Primary

Hammond Manufacturing|

MPN: 714

|

UPC: 623980285702

In Stock
$94.84

Ships from and sold by A5 IT

Ground Shipping · $21.16Arrives by Monday, Oct 26
Order within 2h 51m to get it by Monday, Oct 26
New, with full manufacturer warranty
Business Pricing Available

Exclusive pricing and Net-30 terms. Sign in or create a free account.

Create Free Business Account

Key Features

  • 1,020V C.T. high voltage (plate) secondary, 200 VA (CCS rating)
  • Secondary current 196 mA CCS / 288 mA ICAS
  • 115 VAC, 50/60 Hz primary (input Black & Black)
  • Runs full wave bridge or full wave C.T.
  • Enclosed construction with 4 hole chassis mount and minimum 6 in long leads
  • Class A insulation (105 degrees C); hi-pot tested at a minimum of twice secondary voltage
  • CSA certified (209651); RoHS and REACH compliant

The 714 is a 200 VA high voltage (plate) transformer from the 700 Series with a 115 VAC, 50/60 Hz primary and a 1,020V C.T. secondary, intended for builders and service technicians who need a centre-tapped plate supply. It is the lightest 1,020V C.T. model in the 700 Series table at 5.5 lbs, rated 196 mA CCS and 288 mA ICAS for lower-current plate supplies.

The high voltage secondary is rated 196 mA under CCS (Continuous Commercial Service) and 288 mA under ICAS (Intermittent Commercial or Amateur Service); the 200 VA figure is a CCS rating. The transformer can be run full wave bridge or full wave C.T. Input is on the Black and Black primary leads. A 117/234 VAC dual-primary version is listed as the 714A.

Construction is enclosed, with a 4 hole chassis mount, minimum 6 in long leads and Class A insulation (105 degrees C). Units are hi-pot tested at a minimum of twice the secondary voltage and the series is CSA certified (209651). The 714 is RoHS and REACH compliant, with a series-table weight of 5.5 lbs (2.49 kg).

Ideal For

  • 1,020V C.T. high voltage plate supply
  • Full wave bridge or full wave C.T. rectified supplies
  • Continuous commercial (CCS) or intermittent amateur (ICAS) service
  • Equipment run from a 115 VAC line

Mounting

Mounting4 hole chassis mount

Overview

Series700 Series - High Voltage (Plate)
DescriptionTransformer, high voltage, 200VA, 115 VAC to 1,020V C.T. @ 196ma., 700 series
Short Description115V 50/60Hz 1020VCT 180VA
117/234 VAC Primary Version714A

Electrical

Frequency50/60 Hz
Hi-Pot TestMinimum of twice secondary voltage
Primary WiringInput Black & Black
Primary Voltage115 VAC
Power Rating (VA)200 (CCS rating)
Rectifier ConfigurationCan be run full wave bridge or full wave C.T.
H.V. Secondary Current (CCS)196ma.
H.V. Secondary Current (ICAS)288ma.
AC High Voltage Secondary R.M.S.1,020V C.T.

Identifiers

UPC623980285702
UNSPSC39121301
Part Number714

Packaging & Shipping

Shipping Weight5.5 lbs (2.49 kg)
Weight (Series Table)5.5 lbs

Construction & Finish

EnclosureEnclosed
Lead LengthMinimum 6" long leads
Insulation ClassClass A (105 degrees C)

Compliance & Certifications

CSA CertifiedYes (209651)
RoHS CompliantYes
REACH CompliantYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Frequently Asked Questions

What is the difference between the 714 and the 714A?▾

The 714 has a 115 VAC primary; the 714A is the 117/234 VAC dual-primary version with the same 1,020V C.T. secondary and 200 VA rating.

How do I wire the 714 primary?▾

On 115 VAC-only models the input is the Black and Black leads.

What do the CCS and ICAS current ratings mean?▾

CCS is Continuous Commercial Service (196 mA for this part) and ICAS is Intermittent Commercial or Amateur Service (288 mA). The 200 VA rating is a CCS rating.

Can it be used in a full wave bridge circuit?▾

Yes. Units in the 700 Series can be run full wave bridge or full wave C.T.

How is the 714 mounted and insulated?▾

It is an enclosed unit with a 4 hole chassis mount, minimum 6 in long leads and Class A insulation rated 105 degrees C.